1 / 15

Manual UU 7001(x)

Manual UU 7001(x). Software Austin Powder Germany GmbH. Structure of menue. Start page. Profile selection. Production-overview. Visualisation. Totalisator. Print. Supervisor passwortd level. Pre-set values checks. Profile editor. Flow. Level. Product pump. Reactive1-pump.

bona
Download Presentation

Manual UU 7001(x)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Manual UU 7001(x) Software Austin Powder Germany GmbH

  2. Structure of menue Start page Profile selection Production-overview Visualisation Totalisator Print Supervisorpasswortd level Pre-set values checks Profile editor Flow Level Product pump Reactive1-pump Reactive2-pump Pressure Water pump Administratorpassword level Adjust pre-set values Basic values Production rate Time-out System control Languages

  3. Operator menue Start page • Start page: After the start release of stored program control (SPC) the display shows for ten seconds the Austin logo and then changes automatically to the page profile selection.

  4. Operator menue Recipe selection • Recipe selection: Here you can select one of 9 loading lengths (profiles) and then 4 different pre-set weights (option 1-4) per line, for different borehole filling and one weight for addditional loading (option +). The different stored weights in the pre-set profile allow a reliable complex blasting profile. 1 4 7 2 5 8 3 6 9

  5. Operator menue Production overview • Production overview: After selection of a recipe, the display shows the page production overview. Unvisible touch key message buffer Selected profile Button Visualization line1 Button Visualization line1 Pressure line 1,2 in the loading hose Produced amount (weight) with line1/line 2 Reset button resets produced amount to 0 Button visualization line1 Produced mass line 1 + 2 Button visualization line1

  6. Operator menue Visualisation This page shows, in a simplified schematic drawing, tank levels, flow, actual pressure, actual status of drives, proper function of safety equipment and position of valves.One view shows if there are normal conditions or deviations! Click to a component name and you will get detailed information about pre-set values of this component. .

  7. Operator menue Pumps When you click to the symbol of a pump or an auger motor drive, the display shows a page with pre-set values for that pump or auger. The page shows the manufacturer, the type and the serial number of the device. Next two lines show actual value of operating hours and operating hours alert . There is a possibility to set different pump rates (speed) for option 1-3 and option 4. To run pump or auger with manual control, the button remote control 0/1 must be in position 1, resp. signal lamp „production“ must be illuminated. If you leave this page when pump is running in manual mode, the pump is stopped automatically when you touch the return key.

  8. Operator menue Flow When you click to the symbol of a flow or temperature control, you have following adoption possibilities: Time out (unsufficient) flow: This time out starts when a flow falls below minimum limit value and stays too low until within time out, resp. scheduled shut down of running production because of this time out. Time out flow during start phase of pump: If flow does not exceed the minimum limit value after pump start, this time out stops running production Time out overtemperature If temperature rises above maximum level limit and does not return within time out, this shuts down running production. Time out wire break/connection failure In case of connection failure or cable break between flow/temperature sensors or pressure transmitters and SPC, the running production is shut down after the time out. Flow rate (only Reactive1 und 2): Shows actual rate. Density (only Reactive1 und 2): Sets the density of the reactive components.

  9. Operator menue Pressure This page is shown when you click into the symbol pressure transmitter. Adoptions of values are only possible with passsword „9“. Minimum pressure control: Set a minimum pressure and a time out production which shuts down production if pressure does not exceed the limit within time. Maximum pressure control: This pressure is the maximum allowed pressure behind detonation trap from safety reasons . If this maximum value is reached actually, pumping is immediately stopped by SPC. Max. pressure redundant-control: This is a second pressure control at the high pressure end of product pump. If the set maximum value is arrived, pump is immediately stopped by SPC. Max. difference pressure control: This set value is the maximum allowed pressure difference between the two pressure measurements.

  10. Operator menue Level When you click to the level symbol , the display will show this page with level settings. Rem.: measured is the hydrostatic pressure, values of level for water (density = 1) are about: 1mbar = 1 cm . Min. Pressure control matrix : If level of matrix in the matrix tank falls below 35 mm and does not again exceed this value within time out, the running process is stopped . Time out pressure control matrix: See above. Offset level (pressure control) matrix: This value is estimated and set during first start of operation of unit.

  11. Operator menue Edit profile Profile name and number Create a new profile. Profile number (s. above) and data set number (first row in profile) must be equal. Attention: Only nine profiles (1-9) are possible! When you edit a profile or created a new one, you must store the new values. Cancel the selected profile. If you want to change a profile name, keep in remind the profile number. Rem.: If you leave this page, all profiles are stored on the USB stick. Then change the name and change from profile number 10 to the number you kept in remind.

  12. Operator menue Basic settings From this page main settings you have 6 possible actions: - View last production report (1) - Set clock with date and time (2) - Shut down control panel (3) - Select language (4) - Set production rate (5) • Set time out of line 1 or 2 (6)After you have made the settings, you can leave this page with the button on the left top corner of the display (7). 7 1 2 3 4 5 6

  13. Production report A production report is stored automatically, after 3 delivery notes, on the USB stick. To evaluate this report, open the file Produktionsbericht_Austin_Powder.xlt on the USB stick with your PC. If you have not activated makros, follow the instructions in excel and set macro-safety to „medium“. To load the report, click with the mouse pointer into the Austin logo. In the next window „Open“ select a load protocol file and open it. The load protocol file name „Ladepro_date_time“ contains date and time of file storeage by UU7001(X)E. Now you can view all stored recorded measured data in an excel sheet. Save the file (rename) on the hard disc of your PC.

  14. Edit profiles on your PC Open the file Abschlagsprofile.csv on USB stick with excel (tag is Semikolon). Profile name Profile number Data record number 150 = 15,0kg If you changed data, click to „store“ and confirm with „yes “ in the excel window. Then close excel. The question in the next excel window to store as Abschlagprofile.csv you must answer with „no“. When you did the desired changes und stored them on the USB stick, conect the stick again with the UU 7001 SPC and select the page basic settings. Touch the button Import and confirm overwriting the existing data with the new ones with „yes“. 6-14

  15. Pass word administration Supervisor Pass word: Powder Administrator Pass word: APGE

More Related