An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Product Line Review

  2. Product Line Review

  3. RS Series • UV & UV / WBIR • Alarm Relay • Analog • Safe Area use only • Fire Sentry still sells a lot of these!

  4. RS Series UV only RS-0010 RS-0010(B) 9 volt battery 12-24 VDC built-in horn non-latching relay NO or NC contacts UV only RS2-0010 FS2-0010(B) 12-24 VDC latching relay NO or NC contacts UV/VIS/WBIR RS2D-00098 FS2DCR-00098 12-24 VDC latching relay non-latching relay form C contacts

  5. Model SS2 • UV / WBIR / VIS • Explosion Proof- Indoor & Outdoor use • Internal Self-Test • FirePic™ • Alarm & Fault Relays • FireBus™ RS485 • Use Unitized or with CM1-A Controller • Versions for specialty applications requiring high speed response, such as Airbag and Munitions manufacturing

  6. Model SS2 (Unitized Mode) • FIRE ALARM Relay – NO/NC Normally De-Energized • FAULT RELAY– NO/NC Normally Energized 24 VDC RS-485 FireBus™ Protocol to PC Note: Sensitivity Setting: 60 feet Electronics Self Test Only

  7. Model SS3 • Safe Area use • UV & UV / WBIR / VIS • FirePic™ • Alarm Relay • FireBus™ RS485 • Use Unitized or with CM1-A Controller

  8. Model SS3 PRODUCT APPLICATIONS • Silane Gas Cabinets • Clean Rooms • Warehouses • Computer Rooms Note: NEMA 1 Enclosure (Use only in Non-Hazardous Areas)

  9. Model SS4 • UV & UV / WBIR / VIS • Explosion Proof - Indoor & Outdoor use • Optical and Internal Self-Test • FirePic™ • Alarm, Verified Fire & Fault Relays • FireBus RS485 • Use Unitized or with CM1-A Controller • Optimized version for Hydrogen, Natural Gas, Methanol & Ethanol Fires

  10. Model SS2 & SS4 PRODUCT APPLICATIONS • Crude & Product Tank Farms • Gas Turbine Enclosures • Gas Collection Facilities • Marine Terminals • Rail Loading & Unloading Terminals • Gasoline Loading Terminals • LNG & LPG Storage and Distribution • Silane Gas Cabinets • Silane Gas Storage • Aircraft Hangars, Commercial and Military • Power Plants • Paints & Solvents Storage • Aerosol Filling Facilities • Cogeneration Plants • Warehouses • Engine Test Cells • Marine Engine Rooms • Petrochemical Plants • Refineries • Petroleum Product Pipelines • Gas Processing Plants • Offshore Drilling and Production Platforms • Gas Compressor Buildings • Petroleum Prod. Pumping Stations • Product Storage Terminals

  11. Model SS4 (Unitized Mode) (1) FIRE ALARM Relay – NO/NC Normally De-Energized (1) FIRE VERIFYRELAY – NO/NC Normally De-Energized (1) FAULT RELAY– NO/NC Normally Energized 24 VDC RS-485 FireBus™ Protocol to PC Note: Factory Sensitivity Setting: 45 feet, (selectable 60, 30 and 15 feet) Through the Lens & Electronics Self Test

  12. FS2000 SYSTEM SS2-A FireBus™ ProtocolRS-485 4 Wire Loop SS4-A (1) MASTER ALARM RELAY - NO/NC Normally De-Energized Up to 30 Devices in the Loop (4) PROGRAMMABLE ZONE ALARM RELAYS- NO/NC Normally De-Energized SS3-A CM1-A Controller (1) FAULT RELAY - NO/NC Normally Energized RS-232PC Communication SS2-A 120 VAC SS4-A

  13. Model FS7 • The World’s largestselling Fire Detector for Semiconductor Wet Benches! • NIR / WBIR / VIS • Two Stage Alarm • FM Approved • Leak-proof, Polypropylene Housing • Unitized or Controller based versions • Six FirePics™ • FireBusII™ RS485

  14. Model FS7 System PRODUCT APPLICATIONS • Clean Rooms • Wet Bench Working Surfaces • Clean Room Pump & Equipment Area • Wet Bench Plenum Area • IPA & Chemical Stations

  15. Typical Location of Detectors Head Case Surface Area detection, includingrobot deck area across Process Tanks Plenum Area under Process Tanks Robot Wafer Load and Unload Area Equipment Area behind Wet Bench

  16. Model FS7 with FS7-130-SX Controller (4) Programmable Zone Alarms NC – Normally De-Energized Zone 1 - ALARM or ALERT Zone 2 - ALARM or ALERT Zone 3 - ALARM or ALERT Zone 3 - ALARM or ALERT FS7-2173 To Next Junction Box Junction Box FS7-130-SX (1) FAULT Relay – NC Normally Energized 24 VDC RS-232 PC Communication 1 to 12 Detectors can be connected to the controller

  17. Model FS7 Detector with FSWB Controller (1) ALERT Relay – NO To Next Junction Box Manual Call Station (1) FIRE ALARM Relay – NO FSWB-1 Contact Device (1) FAULT Relay – NC (1) 24 VDC ReleasingCircuit (1) 24 VDC Annunciator(0.15A) Junction Box FS7-2173 (1) 24 VDC Output (0.1 A) RS-232PC Communication 120 VAC 1 to 9 Detectors can be connected to the controller

  18. Model FS7-2173-2RP Unitized Fire Detector (1) ALERT Relay – NO Normally De-Energized • (1) FIRE ALARM Relay – NO Normally De-Energized (1) FAULT Relay – NC Normally Energized RS-485 FireBus II™ Protocol to PC 24 VDC

  19. Model FS10 • For use with ElectrostaticLiquid and Powder PaintApplications • NIR / WBIR / VIS • Complies with NFPA 33 • Explosion Proof - Indoor use • Unitized, Card Controller orWallmount Control Panel Systems • FirePic™ with FireBusII RS-485

  20. Model FS10 PRODUCT APPLICATIONS • Electrostatic Liquid Paint Spray Line • Electrostatic Powder Coating Booths • Paint Drum Storage & Paint Mix Rooms • Aerosol Filling • Automotive Engine Testing • Infrared Curing Ovens • Diesel Generators (Indoors) • Gas Compressor Stations (Indoors)

  21. Model FS10 Wallmount Controller (1) ALERT Relay – NO/NC Normally De-Energized(0.5 sec Response) Primary Application:Paint Booths (1) FIRE ALARM Relay – NO/NC Normally De-Energized(4 sec Response) 120 VAC (1) FAULT Relay – NO/NC Normally Energized (3) PROCESS SHUTDOWNRelays – NO/NCNormally Energized Note: Detector Sensitivity is 15 or 30 Feet RS-232PC Communication

  22. Model FS10 Card Controller (1) ALERT / FEWRelay NC Normally Energized(0.5 sec Response) General Finishing: Liquid & Powder Coating (1) FIRE ALARM Relay – NO Normally De-Energized(4 sec Response) 120 VAC (1) MAJOR FAULT – NO/NC Normally Energized Model 2GF (1) MINOR FAULT – NO Normally De-Energized Note:Detector Sensitivity: 15 or 30 Feet RS-232 PC Communication

  23. Model FS10-R Unitized Detector(Relay Output Version) (1) ALERT Relay – NO Normally De-Energized(0.5 sec Response) General Finishing: Liquid & Powder Coating (1) FIRE ALARM Relay – NO Normally De-Energized(4 sec Response) (1) FAULT Relay – NC Normally Energized RS-485 FireBus II™ Protocol to PC 24 VDC Note: Detector Sensitivity: 15, 30, or 45 Feet, (no ALERT relay with 45 ft. sensitivity)

  24. Model FS10-A Unitized Detector(Analog Output Version) ALERT: 12 mA(0.3 sec Response) General Finishing: Liquid & Powder Coating ALARM: 20 Ma(4 sec Response) NORMAL: 4 mA FAULT: 0 mA 24 VDC RS-485 FireBus II™ Protocol to PC Note: Detector Sensitivity: 15, 30, or 45 Feet, (no ALERT relay with 45 ft. sensitivity)

  25. Product Line Review