130 likes | 347 Views
Cavity Measurements. By Aaron Cheng 4 May 2007. Overview. RF measurements Waveguide-coax transition. RF measurements. FETS 4-vane RFQ copper cold model in Imperial College. RF measurements. Input couplers used. RF measurements. Some coupling stability problems. RF measurements.
E N D
Cavity Measurements By Aaron Cheng 4 May 2007
Overview • RF measurements • Waveguide-coax transition
RF measurements FETS 4-vane RFQ copper cold model in Imperial College
RF measurements Input couplers used
RF measurements Some coupling stability problems
RF measurements Some coupling stability problems
Waveguide-coax transition • Studying doorknob wg-coax • Coupler with coaxial RF window • S11 = -14.7527dB • S21 = -0.14029dB
Waveguide-coax transition • Studying doorknob wg-coax • Coupler with planar RF window • S11 = -35.2005dB • S21 = -0.000034dB
Waveguide-coax transition • Studying doorknob wg-coax • Coupler with planar RF window • S11 = -33.7465dB • S21 = -0.00015221dB
Waveguide-coax transition • Studying t-bar wg-coax • Coupler with coaxial RF window • S11 = -59.6085dB • S21 = -0.018748dB
Waveguide-coax transition • Studying t-bar wg-coax • Coupler with planar RF window • S11 = -27.1593dB • S21 = -0.0095028dB
Waveguide-coax transition • Thermal analysis • Vacuum pumping ports and requirements • Electron probes and threshold • Connecting flanges
Summary • Bead pull measurement to be conducted more with unbrazed and brazed RFQ • Waveguide-Coax transition will stop at current status until after PAC conference • Other matters: • Microwave signal generator and amplifier have arrived, currently placed in RAL