Prototype Calibration System for Forward Hadron Calorimeter

Prototype Calibration System for Forward Hadron Calorimeter. L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH. Electronic pulser for ~100 ns LED pulses w/ single-shot and external trigger capability. 10 m jacketed light fiber. 1->4 light splitter.

Download Presentation

Prototype Calibration System for Forward Hadron Calorimeter

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Prototype Calibration System for Forward Hadron Calorimeter L. Almeida, M. Baarmand, L. Caraway, M. Hohlmann, T. Qureshi, I. Vodopianov FLORIDA TECH Electronic pulser for ~100 ns LED pulses w/ single-shot and external trigger capability 10 m jacketed light fiber 1->4 light splitter 1->9 light splitter w/ pulsed LEDs, input for UV laser pulses, and PIN diode light monitoring

  2. HF Calibration Optical Fiber Path Test Beam 2002 Counting Room N2 Laser 200 mJ 337 nm 300 QQ 75m 9 PMT Boxes 9 PMT Boxes 1  4 300 QQ 9m 9 PMT Boxes 9 PMT Boxes Bottom Rack 9 Calib Box 600 QP 18m

  3. Calibration Box -1 x 9 splitter PIN Diode 4mm  4mm 300 QQ ADC LED 1 PIN2 MIXER 50mm  15mm  15mm Polystyrene PIN1 PIN3 LED 2 600 QP 9 Blue Scintilator 8mm  4mm  8mm Pulser To PMT Box

  4. PMT BOX SHIELDING Empty PMT TUBE (CLI) 40cm 600 QP 120 Calibration Tube Light Guide Non-reflective coating 600 QP 5 PMT Light Guide Light Guide

  5. Calibration Light Injector (CLI) Plate 3 Plate 2 Calibration Tube Fiber Ferrule Holographic Diffuser SMA Connector 9cm SMA-SMA connector Jacket Fiber 600 QP SMA Connectors Aspheric Lens 11mm Focal Length Collimation Assembly

  6. 1 2 • One-PE Response: • Plot#1 111 or 117 ADC counts • Plot#2 106 ADC counts • Plot#3 104 ADC counts • =>stable laser pulse 3

  7. PMT 154 (315 E22) behavior PMT relative gains for ROBOX 3 measured in Iowa: PMT N 148 149 150 151 152 153 154 155 156 157 158 159 160 161… Gain % 48 74 74 76 76 76 77 78 96 97 98 100 102 104… High output, narrow peak Usual pedestal …

  8. PMT (PE) / (Laser / Laser100%)

  9. LED Data 1 LED at threshold V 2 LED at 10 V

  10. Comparison of PMT response to laser and LED at similarlight intensity

  11. 2 LED at 10 V (close intensity) Laser 48%

  12. ADCC = (ADC-Pedestal) / Gain

  13. ADCC

  14. 1 x 4 splitter 75 mm 300m QQ 1000m QQ (Silica) 300m QQ SMA Connectors Fiber to Fiber ratio = (1/0.3)2 11 Average in/out measurement  22

  15. Splitter study PMT 154 “best” 1  4 splitter attenuation: no red fiber light 1 50 43 25 2 49 42 22 3 42 36 22 4 43 37 18 1 2 3 4

  16. 100% laser intensity corresponds to 360 GeV electron

  17. 100% laser int. corresponds to 933 GeVp for E-PMT 1467 GeVp for H-PMT

  18. Questions • Are fibers in calibration and PMT bundles polished? • How many calibration fibers are used for PMT 154 (315)? What is different in calibration lightpipe for this PMT? • Which PMTs have bad light guides?

  19. Concerns • Insufficient laser intensity (attenuation factor 12 in 150m fiber)  place UV laser closer to detector or use blue laser • Build (or buy) low attenuation splitter