140 likes | 278 Views
Calorimeter calibration procedure. Calorimeter data quality. 3 main steps can issue quality status: On line monitoring E-flow calibration Electron and photon caracteristic Final calibration. 1. On line monitoring. From calibration farm for ECAL/HCAL/PS/SPD
E N D
Calorimeter calibration procedure Calorimeter Calibration scheme
Calorimeter data quality • 3 main steps can issue quality status: • On line monitoring • E-flow calibration • Electron and photon caracteristic • Final calibration Calorimeter Calibration scheme
1. On line monitoring • From calibration farm for ECAL/HCAL/PS/SPD • Detect dead & noisy channels • Non working detector part • Follow the gain variation with the LED system • Analyse the rate of variation • Eventually change the database • Criteria have to be defined • In link with Calo piquet . Olivier-Serguey Calorimeter Calibration scheme
2. XCAL inter cell calibration to 5% (1) • For ECAL • From gain calculation cell intercalibrated at 10% • HCAL (3%) Cs source • PS 10% (MIP) • Smoothing E-Flow response method on each channel -> 4-5% • Use neighboour average • Use detector symetries • For ECAL/HCAL/PS Aurélien -Frédéric HCAL ECAL Calorimeter Calibration scheme
2. ECAL inter cell calibration to 5% (2) Dead channels Calibration exercise 10M evts 10% Miscalibration cell to cell Dead channels Cell to cell calibration at 5% level Calorimeter Calibration scheme
2. ECAL inter cell calibration to 5% • Statistics needed 10millions events • For each cell ECAL/HCAL/PS • Calibration factor is issued • Will take few day(s) when the required statistic is available • Will need ressource for this step Calorimeter Calibration scheme
2’. Calibration with p0 mass • When updated database , use reconstructed p0 using the cell calibration ( off-line) The p0 mass peak will be fitted : Ecal energy scale ~ 1-2% Inter cell calibration ~ 5% Update of the database for - Cells coefficients - Calibration factor HV settings can be changed instead of database update Olivier This is the precalibration phase – Data can be processed with this calibration Calorimeter Calibration scheme
Build quality reference • Most of the variable used in electron or photon identification can be accessed in fully reconstructed events But also Et ditribution , multiplicity etc ..; PID estimator Olivier-Dmitri-Victor Calorimeter Calibration scheme
Calibration to 1% for ECAL(1%) • Methods developped for calibration using : • p0 : Albert Puig - Vanya • 2 photons combination • Background • From photon –x,-y • 6000 cells • Iterative method • Fit method • 80 to 200 Millions • Methods experienced on Decaibrated data 200Mevts Calorimeter Calibration scheme
Calibration ECAL to 1% • With electrons : • Using RICH PID (Oleg) • Electron from conversion (S.T’J) • Electron from J/psi (Ricci) Fits will statistics 30- 100 millions of events Calorimeter Calibration scheme
FemtoDST • For calibration with p0 • Iterative procedure or fit on a very large number of event • Calibrationwith ellectron • Fit with a very large number of events • Vanya design a tool able to reduce data flow • for iterativee procedure • Kali-Calo • Running on DST • Procedure will be redone regurlarly .. Calorimeter Calibration scheme
Data Flow for Kali-p0 (I) ROOT NTuple/TTree DST or DAQ Kali-p0 Job Vanya fmDST 6 Oct 2k+9 Vanya Belyaev (Nikhef & ITEP ) 12 Calorimeter Calibration scheme
Data Flow for Kali-p0 (II) • 2k+(4-5): 3-5 iterations are OK • 2k+9 : 2-3 iterations are OK • Make histos using the current estimate for calibration constants • Fit histograms • Get corrections for calibration constants • Iterate up to convergency • produce the final set of calibration constants ROOT NTuple/TTree Set of Calibration constrants CondDB (?) (optional) 6 Oct 2k+9 Vanya Belyaev (Nikhef & ITEP ) 13 Calorimeter Calibration scheme
Plans • Produce selections tools for the different photon and electron approach • Produced from 200Milions decalibrated ->femto DST • Apply the calibration procedures ; • Timescale 6 weeks; • Given theprocedure to reach 1% : • When reached >100Millions events • Calibration will update the database ~few weeks after To be discussed the procedure to produce the FemtoDST Calorimeter Calibration scheme