A case study on using Synthea data for clinical quality measures, focusing on CMS165 Controlling High Blood Pressure. The study identifies missing data elements, unmet result values, and the need for accurate terminology. It also provides solutions for generating hypertension patient data using Synthea.

brodbeck
Download Presentation

Using Synthea Generated Patient Data for Clinical Quality Measure

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Use Synthea Generated Patient Data for Clinical Quality Measure – Case Study: CMS165 Controlling High Blood Pressure Peter Li, OSEHRA 2/21/2019

  2. Objective • Determine what is needed for Synthea to generate patient data for use in clinical quality measure (CQM).

  3. Gap Analysis and Validation • Start with a CQM where the disease of interest has been modeled by Synthea • Match CQM data elements with those generated by the Synthea data. • Provide a list of CQM required data elements: • Missing from Synthea • Using terminology (SNOMED code) not included in the value set • Unmet result values • Test Synthea data in C-CDA format against popHealth – a CQM Reporting Tool

  4. CMS165 – Controlling High Blood Pressure • CQM definition - https://ecqi.healthit.gov/system/files/ecqm/measures/CMS165v7.html • Data criteria used in the Denominator: • Diagnosis: Essential Hypertension • Encounter, Performed: Adult Outpatient Visit • Data criteria used in the Numerator • Physical Exam, Performed: Diastolic blood pressure (Has Diastolic Blood Pressure Less Than 90) • Physical Exam, Performed: Systolic blood pressure (Has Systolic Blood Pressure Less Than 140) • Data criteria used in the Denominator Exclusions • Diagnosis: Chronic Kidney Disease, Stage 5 • Diagnosis: End Stage Renal Disease • Diagnosis: Kidney Transplant Recipient • Diagnosis: Pregnancy • Intervention, Order: Hospice care ambulatory • Intervention, Performed: Hospice care ambulatory • Procedure, Performed: Dialysis Services • Procedure, Performed: Kidney Transplant • Procedure, Performed: Vascular Access for Dialysis

  5. CQM Data Criteria Value Set • Diagnosis: Essential Hypertension as defined by the value set - 2.16.840.1.113883.3.464.1003.104.12.1011

  6. Example of Using Terminology Outside of the Value Set • The Synthea module - Metabolic Syndrome Standards of Care generates the Hypertension diagnosis; however, the SNOMED code used, 38341003 (Hypertensive Disorder), is a more general classification of hypertension. The CQM data criteria for Diagnosis: Essential Hypertension is more specific. Therefore, we will need to change the Synthea Hypertension Diagnose code to one of the code in the value set, i.e., 59621000 (Essential hypertension)

  7. Example of Unmet Result Values • The CMS165 numerator requires indication that the hypertension is under control, i.e., • Physical Exam, Performed: Diastolic blood pressure (Has Diastolic Blood Pressure Less Than 90) • Physical Exam, Performed: Systolic blood pressure (Has Systolic Blood Pressure Less Than 140) • The Synthea module - Metabolic Syndrome Standards of Care, only generates Diastolic/Systolic blood pressure >= 90/140 once hypertension diagnose is set. Even after the medication, the BP values doesn’t drop, so no patient will fall into the numerator.

  8. Example of Missing Data Elements • Diagnosis: Chronic Kidney Disease, Stage 5 • Diagnosis: Kidney Transplant Recipient • Intervention, Order: Hospice care ambulatory • Intervention, Performed: Hospice care ambulatory • Procedure, Performed: Kidney Transplant • Procedure, Performed: Vascular Access for Dialysis

  9. Synthea Hypertension Module • Create a Hypertension module based on the Metabolic Syndrome Standard of Care module which had a section that modelled hypertension. • Changes added: • Hypertension Diagnose code to one of the code in the value set, i.e., 59621000 (Essential hypertension) • Created follow up encounters that included Diastolic/Systolic blood pressure readings that indicated control of blood pressure, i.e., <90/140 mmHg. • Updated the Synthea property file to generate c-cda • To view the model, load the hypertension.json - https://github.com/OSEHRA/Synthetic-Patient-Data-Project/blob/master/models/hypertension/hypertension.json into the Synthea Module Builder - https://synthetichealth.github.io/module-builder/

  10. Synthea Generated Hypertension Patient • Removed the Metabolic Syndrome Standard of Care module because of dependencies. • Generated 1000 patients, of which 270 patients had 59621000 (Essential hypertension) diagnosis. • Imported the 270 patients on popHealth. • Performed CMS165 measure calculation on the imported patients.

  11. Results from PopHealth

  12. Observations of the CQM Calculation for Measure Period from 1-1-2018 to 12-31-2018 • Hypertension patients not included in the initial population due to lack of outpatient encounter during 2018 year. • Patients not included in the numerator due to lack of controlled BP measurements • Patient excluded from the denominator because of pregnancy.

  13. Conclusion • Synthea generated patient data can be used for clinical quality measure. It’s a matter of making sure that the generated SNOMED code is a member of the value set defined by the measure’s data criteria. This applies to encounter types, diagnosis, medications, etc. • Hypertension module used for the case study doesn’t model gestational hypertension.