1 / 31

UL 62 Flexible cords and Cable 制作人:袁林斌 2008.7.21

UL 62 美标电线标准培训讲义. UL 62 Flexible cords and Cable 制作人:袁林斌 2008.7.21. UL 62 美标电线标准培训讲义. Contents/ 内容 A.Scope/ 范围 B.Definitions and Units of Measurement/ 定义与测量单位 C.General Construction Requirements/ 总的结构 - conductor (tests involved)/ 导体 - insulation (tests involved)/ 绝缘体

buzz
Download Presentation

UL 62 Flexible cords and Cable 制作人:袁林斌 2008.7.21

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. UL 62美标电线标准培训讲义 UL 62 Flexible cords and Cable 制作人:袁林斌 2008.7.21

  2. UL 62美标电线标准培训讲义 • Contents/内容 • A.Scope/范围 • B.Definitions and Units of Measurement/ 定义与测量单位 • C.General Construction Requirements/总的结构 • - conductor (tests involved)/导体 • - insulation (tests involved)/绝缘体 • - covering/遮盖物 • - jacket (tests involved)/外被 • - finished cords (tests involved)成缆 • - Markings/印字 • D.Q & A

  3. UL 62美标电线标准培训讲义 • A.Scope/范围 • 电压: 600V max • 温度: 60, 75, 90, to 105 C Max • 电流: Proper size and type • corresponding to its appropriate • ratings is to be selected for used • in conjunction with applicable end-use • Product standards.(18AWG 10A;16AWG 13A; • 14AWG 15A;12AWG 20A)

  4. UL 62美标电线标准培训讲义 • 本标准涵盖了各种可绕曲软线,电梯线和起 • 卸用线,但不包括铠装电缆及电压超过 • 600V的电线电缆也不包括加装各种端线接头 • 的电线电缆。

  5. UL 62美标电线标准培训讲义 B.Definitions and Units of Measurement 定义与测量单位 Service Cords – ( e.g. SPT-2, SJT, ST, - -)耐用线 Elevator Cables – ( e.g. E, EO, ETT, ETP)升降机电线 Heater Cords – ( e.g. HPN, HPD, HSJ, HSJO)耐热线 Range and Dryer Cords – ( e.g. SRD, SRDE) Decorative Lighting Cords – ( e.g. XTW, CXTW) Tinsel Cords – ( e.g. TPT, TST) Special Use Cords – ( e.g. C, PD) Vacuum-cleaner Cords – ( e.g. SV, SVO, SVT) Hoistway Cables – ( No Type Designation )

  6. UL 62美标电线标准培训讲义 常见术语: 命名—利用前后缀区分 1.E在第一位:电梯线 2.E位于第一个字母后:绝缘是热朔性弹性体(TPE)例如SE SEO 3.H: 加热线 例如 HPN 4.NI :Non-intergral当使用在平行线中就如:NISPT-I,表明绝缘和外被 分开的 5.P: 平行线 例如 SPT-1 SPT-2 SPT-3 6.S: 用于超负荷设备和手持式器具,工具,其机械适用性等级最高 例如 S T 7.SJ: 用于重负荷设备和手持式器具,工具,其机械适用性等级中等 例如 SJT 8.SV用于轻型设备和手持式器具,工具,其机械适用性等级最低 例如 SVT

  7. UL 62美标电线标准培训讲义 9.T: 在第一个字母的后面,热塑性材料绝缘.例如 ST 10.O:耐油, 一个”o”表示外被是耐油;两个O说明外被和绝缘 都是耐油的,例如SVTOO,SJTOO,STOO 11.-1: 平行绝缘最薄 -2:次薄,比-1厚 -3: 最厚 12: XTW: 圣诞灯串用的平行线 13: CXTW: 圣诞灯串用的绞合线或者单支线 14: W: 最后一个字母为W说明是抗潮和抗紫外线的.

  8. UL 62美标电线标准培训讲义 测量单位 Mil– unit of length equal to 1/1000 of an inch (0.0254 mm). (1mm= 39.37 mils) (Strand Diameter, Insulation/Jacket Thick.) Circular Mil (cmil) (CM) – A unit of area equal to the area of a circle whose diameter is 1 mil (0.001 inch, 0.0254mm). Used chiefly in specifying cross-sectional areas of round conductors. The area of a circle in circular mils is equal to the square of the diameter in mils. [area (cmils) = diameter (mils)² ]

  9. UL 62美标电线标准培训讲义 C.Construction/结构

  10. UL 62美标电线标准培训讲义

  11. UL 62美标电线标准培训讲义 • 导体 • 绞合线 • 退火铜 • 尺寸 • 绞合方式 • 绞距

  12. UL 62美标电线标准培训讲义 • 1.导体尺寸: • 测试设备及方法: • 千分尺 • 截面积测试方法一: 测量每一根绞合芯线截面积之和,测量时 至少要取7根芯线直径的平均值作为芯线的直径 • 截面积测试方法二: 称重法

  13. UL 62美标电线标准培训讲义 2.导体绞距: 在复绞导体中,组成每一束绞单元的单线节距,不能大于该束绞单元外 径的30倍 对于8AWG或更大尺度的复绞导体,最外层的节距符合表中的要求,其他 不做要求 对于复绞导体中的同心绞单元,每个绞含单元的单线节距应为同心绞单 外径的8-16倍 7根单线绞合的节距应为导体直径的8-16倍

  14. UL 62美标电线标准培训讲义

  15. UL 62美标电线标准培训讲义 • insulation /绝缘体 直接覆盖在导体或者分离体上,绝缘材料 等级见下表

  16. UL 62美标电线标准培训讲义

  17. UL 62美标电线标准培训讲义 1.绝缘厚度: 精度为0.001mm的千分尺,读数显微镜,或者光学投影仪 使用光学显微镜允许有3mils(0.08mm)的误差;

  18. UL 62美标电线标准培训讲义 绝缘厚度中必须测量的要点: 平均绝缘厚度,最小绝缘厚度,撕开后最小绝缘厚度,导体间距.

  19. UL 62美标电线标准培训讲义 2.绝缘的组合: 绝缘的组合请见下表:

  20. UL 62美标电线标准培训讲义 3.成缆节距: 成缆经机器绞合后,其节距有规定值,不能大于UL62标准 Talbe10的数值

  21. UL 62美标电线标准培训讲义

  22. UL 62美标电线标准培训讲义 • covering/遮盖物 • 覆盖层 • 填充物 • 屏蔽层

  23. UL 62美标电线标准培训讲义 1.覆盖层可以是 Braid 编织 Tape 绕包 Nylon covering尼龙覆盖层,如果有尼龙覆盖层,则必须通过弯 曲测试 2.填充物: 和绝缘芯线绞合在一起 形成圆形截面 3.屏蔽层 在一个或者多个导线之上 在外被之下,缆芯之上 金属或者金属聚酯膜 屏蔽覆盖率至少为85% 对于10AWG或者小一些尺寸的线,绞合的每一根应是36AWG或者 34AWG,反之,应是32AWG或者30AWG.

  24. UL 62美标电线标准培训讲义 • Jack/外被 外被材料等级见下表

  25. UL 62美标电线标准培训讲义 1.外被厚度: 测试方法及要求与绝缘一样 2.外径 具体参数请见下表

  26. UL 62美标电线标准培训讲义

  27. UL 62美标电线标准培训讲义 • finished cords (tests involved)成缆 1.外径 2.耐压测试 3.火花机测试 4.燃烧测试 5.印字耐磨

  28. UL 62美标电线标准培训讲义 • Marking/标志 1.电流的参数或者”Outdoor”的字样不能够 出现在线上 2.如果印字不是连续的,则相互之间的间距不能大于 600mm 3.要求的印字内容: a.UL/CUL的认证标志 b.制造商: 工厂名称或制造商代码和制造商标志 任何编码标志的含义应当可以查阅 c.UL档案号 d. 软线型号,规格,线芯

  29. UL 62美标电线标准培训讲义 e.温度 f.电压 4.加拿大和墨西哥,尺寸为mm2(awg) 在美国,尺寸为AWG,mm2可选,例如: (1).3x 3.31mm2 (12AWG)or 3x3.31mm2 (12AWG) (2).3/C3.31mm2(12AWG) or 3/C12 AWG(3.31MM2) 5. 对于任选的-50度,-60,-70下做试验的软线,户外 供电软线表面标志可括一个适用的”-50,-60,-70 “标志,在任何情况下,文字”minus”可以代替”-” 或标志”防水”或防水60C,可包含在户外供电线 的标志中.

  30. UL 62美标电线标准培训讲义 10.燃烧等级: 产品如果通过相应的燃烧性能测试,应该有如下的印字: ---FT1 产品通过FT1 燃烧测试 ---FT2 产品通过FT2燃烧测试 ---VW-1,产品通过VW-1 燃烧测试 如果印了”VW-1”,无需印”FT-1,FT2”;如果印了FT1,无需印FT2 ,但至少要有一个燃烧等级的印字. 任何通过VW-1燃烧试验并在表面印上VW-1标志的软线,还可标上 FT1标志,任何通过VW-1或FT1燃烧试验的电缆或软线,可仅标上 FT1标志,即使1根或多根线芯(动力线芯和接地线芯)未做燃烧 试验或者未通过VW-1试验. 11.如果通过油性测试,则相应的型号字样必须有”O”字样出现 例如: SJO,STOW等.

  31. UL 62美标电线标准培训讲义 6.结构和性能符合屏蔽供电软线或真空吸尘软线,除了上述要求外 ,还应印上标志”Shielded” 7.含一根接地线芯的SP-1,SP-2,SPE-1,SPE-2,SP-3等,软线,应在 其表面印上下述合适字样:”绿色线芯仅供接地用”或”绿色含黄色 条纹的线芯仅供接地用”或”绿色含有或不含黄色条纹的线芯仅供 接地用” 8.对于20AWG SPT-1,PXT型软线,除了所述标志外,还应包括这样 的说明: 本产品不对公从零售” 9.如果SPT-2型软线采用30AWG单线,则在每个线盘或线圈上的标 志除了上述外,还应包括这样的说明:”仅用于通用延伸软线组件” 10.燃烧等级: 产品如果通过相应的燃烧性能测试,应该有如下的印字: ---FT1 产品通过FT1 燃烧测试 ---FT2 产品通过FT2燃烧测试