P P+ T R A I N I N G P R E S E N T. Robin Wu. How PP+ Works?. ( Secondary Arm). ( Primary Arm). Wafer Handler Processing Steps. Wafer Handler Processing Steps. 10. When implant complete, the primary arm will go to the platen and remove the wafer. Wafer Handler Processing Steps.
E N D
PP+ TRAINING PRESENT Robin Wu
How PP+ Works? (Secondary Arm) (Primary Arm) VSEA Confidential
Wafer Handler Processing Steps VSEA Confidential
Wafer Handler Processing Steps 10.When implant complete, the primary arm will go to the platen and remove the wafer. VSEA Confidential
Wafer Handler Processing Steps 15. The elevator goes to nest one slot. And the process repeats from step 1. VSEA Confidential
Software Different VSEA Confidential
ECO’s and Options Settings VSEA Confidential
Initialization Screen VSEA Confidential
Manual Screen VSEA Confidential
Dual Arm calibrations - Level • Lower Handler VSEA Confidential
Dual Arm calibrations - Level • Upper Handler VSEA Confidential
Dual Arm Controller Install VSEA Confidential
Dual Arm Controller Offset Upper Lower E15000206 Lower Upper VSEA Confidential
Controller Settings - Tuning Procedure VSEA Confidential
Controller Settings - Zero Off set R29 • 1.Handler Stop • 2.Measure TP1 and TP3, adjust R29 to 0.000 +-0.001VDC. • 3.Measure J4-1 & J4-2, adjust OFFSET on PCB’s amplifier to 0.000 +- 0.020 VDC. • Repeat step 2 & 3 until both measurement close to 0 VDC. J4-1 & J4-2 TP1 & TP3 VSEA Confidential
Upper Handler Install VSEA Confidential
Upper Handler Calibration- Idle • [Stop] and move the Upper Handler to the hard stop. • Key in the revised number. VSEA Confidential
Upper Handler Calibration- Home VSEA Confidential
Upper Handler Calibration- Platen VSEA Confidential
Orienter calibration VSEA Confidential
Orienter Calibration Low Position VSEA Confidential
Orienter Calibration High Position VSEA Confidential
Orienter Calibration High Position VSEA Confidential
Reflective Wafer Sensor VSEA Confidential
Reflective Wafer Sensor Sensitivity Adjustment Operation mode selector switch Sensitivity adjustment trimmer • The red LED indicate the sensor output is on • The green LED indicate the sensor operation is stable VSEA Confidential
1. Set the Mode Selector Switch to the “L” position. • 2. Move the reflective tape away from to the sensors view. • 3. Rotate the sensor fully CCW and then rotate the trimmer CW until the red LED illuminates. “A” Position Fully CCW then CW to illuminate the “Red” LED. VSEA Confidential
4. Move the reflective tape under the sensor and verify the green and red LEDs are on . • 5. Tune the trimmer CCW from “A” until the green LED off. “B” Position • 6. Adjust the trimmer to the center of “A” & “B” VSEA Confidential
Cycle Test (VAC) VSEA Confidential
Implant Monitor Screen VSEA Confidential