Transients scenarios for the cryogenic operation of superconducting magnets of LHC experiments

Transients scenarios for the cryogenic operation of superconducting magnets of LHC experiments. Experience at CERN R.Pengo CERN, AT-ECR. Content of the presentation. Details for CMS and ATLAS of: cooling down process static heat load dynamic heat load fast discharge of the magnets

caine
Download Presentation

Transients scenarios for the cryogenic operation of superconducting magnets of LHC experiments

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Transients scenarios for the cryogenic operation of superconducting magnets of LHC experiments Experience at CERN R.Pengo CERN, AT-ECR

  2. Content of the presentation • Details for CMS and ATLAS of: • cooling down process • static heat load • dynamic heat load • fast discharge of the magnets • recovery after a fast dump

  3. Structure of the s/c magnets • CMS is composed of • a s/c solenoid, divided in 5 sectors • ATLAS is composed of • a s/c Central Solenoid (CS) • a Barrel Toroid (BT), formed by 8 s/c race-track coils • 2 End Cap Toroids (ECT), each formed by 8 s/c squared coils

  4. Cooling methods for CMS & ATLAS • CMS • The solenoid is indirectly cooled by LHe, driven by thermosyphon movement (i.e. gravity driven) • ATLAS • The CS is indirectly cooled either by the JT circuit of the Main Refrigerator (MR) or by thermosyphon movement • Both BT and ECT’s coils are indirectly cooled by forced LHe flow produced by a 1.2 kg/s centrifugal pump

  5. Cold Mass Inventory • CMS total cold mass is 220 Tons (cylinder 6.6 m x 12.5 m) • ATLAS total cold mass is ca. 700 Tons • CS ca. 6 Tons (cylinder 2.5m x 5.3m) • BT (340 +20) Tons (8: 25 m x 5 m) • ECT’s (2 x 160) Tons (8: 5m x 5m)

  6. Where we are with the commissioning • Actual status: • CMS fully tested on the surface • ATLAS • CS fully tested (surface and cavern) • BT fully tested (surface and cavern) • ECT-A tested at LN2 temperature on surface • ECT-C under test on the surface

  7. Cooling down of the Magnets

  8. Cooling down of the Magnets • CMS 1.2 kW @ 4.5 K Refrigerator used DT< 22K 10 days Cooling Time ca. 22 days

  9. Cooling down of the Magnets • ATLAS :CS • Shield Refrigerator (SR) & Main Refrigerator (MR) used 4 days • SR for shield • MR for CM SR: Cold Mass and shield in series 75 K

  10. Cooling down of the Magnets • ATLAS :BT • Shield Refrigerator (SR) & Main Refrigerator (MR) used 10 days Start of the 1.2 kg/s LHe pump • SR for the shields • MR for Cold mass SR: cold mass and shield in parallel

  11. Cooling down of the Magnets • ATLAS :BT • Shield Refrigerator (SR) & Main Refrigerator (MR) used DT< 40 K

  12. Cooling down of the Magnets • ATLAS : ECT-A 10 Days Only LN2 precooler used

  13. Cooling down of the Magnets • ATLAS : ECT-C (in progress) 10 days

  14. STATIC HEAT LOAD

  15. STATIC HEAT LOAD • CMS • Measured by LHe level decreasing in Phase Separator • Natural Temperature increasing on the cold mass

  16. STATIC HEAT LOAD Débit AdI 2 x 0,4 g/s Dniv(A-B) = 6,75% en 10’= Soit 277 l/h Bilan = 254 l/h = 178 W A B • CMS: Measured by LHe level decreasing in Phase Separator (178 W) LHe level in Phase Separator From Ph. Bredy, CEA Saclay

  17. STATIC HEAT LOAD • CMS: Natural Temperature increasing of the cold mass (174 W) Cold mass bilan : NbTi 4.9 t Cu 8.6 t Al pur 73.9 t Al renf 6082 90.4 t G10 9.9 t Al cyl 5083 34.8 t 10 K •  2 K/ 21 ½ min = 154 W on Cold mass alone • (SdP heat loads to be added 20 W) • Total = 174 W CDS synchronization ! 5 K From Ph. Bredy, CEA Saclay

  18. STATIC HEAT LOAD • ATLAS: CS • Measurement of total loss was done during thermosyphonoperation mode with disconnected refrigerator and looking at the level/time change in the control dewar Results: - 17 Watts for the solenoid and the chimney; - below 10 Watts for the dewar.

  19. STATIC HEAT LOAD • ATLAS: Barrel Toroid CM • For each of the 8 race-track coils the heat load has been measured • in the surface test hall (Mass-flow meter) • in the UX15 cavern after assembling into BT (natural temperature increase) • The total heat load of the BT has been also measured in the cavern

  20. STATIC HEAT LOAD • ATLAS: Barrel Toroid Tmax, Tmin on coils Tin-Tout on the pipes Pt1000 Carbon resistors

  21. STATIC HEAT LOAD • ATLAS: Barrel Toroid Values measured in test station TOTAL MEASURED IN TEST STATION 571 W TOTAL IN UX15 IS 586 W

  22. STATIC HEAT LOAD • ATLAS: Barrel Toroid LHe Pumps: 660 W PCS+TL11+Cryoring: 250 W BT: 620 W (or 1530-660-250)W

  23. STATIC HEAT LOAD • ATLAS: Barrel Toroid Shields • For each of the 8 cryostats • in the surface test hall (Mass-flow meter) • Average 800 W • the total heat load of the BT shield has been also measured in the cavern (Mass-flow meter) • Total 6000 W

  24. DYNAMIC HEAT LOAD

  25. DYNAMIC HEAT LOAD • Flux is proportional to Current: • Φ = L x I , V = -dΦ /dt = - L x dI/dt • Voltage is induced when changing current • And energy is dissipated by the induced current on the casing (~ autotransformer) Al Coil casing 2 x 60 = 120 turns

  26. DYNAMIC HEAT LOAD • ATLAS: Calculated: No Fit! Slow dump equivalent One coil: L = 0.5667 H, Total BT: L= 5.5 H => expected value 350 W

  27. DYNAMIC HEAT LOAD • ATLAS: BT Level of LHe is reduced due to the higher vaporization during slow discharge

  28. DYNAMIC HEAT LOAD • ATLAS: BT LHe vapor mass flow on the phase separator is increased due to the higher heat load ~380 W

  29. DYNAMIC HEAT LOAD • ATLAS: CS • Eddy current loss are around 25 Watts. • Measurement principle: • compare consumption during ramp up at 6 A/s with previously measured static losses by looking at the heater power in the control dewar which is reduced by 25 watts. • Furthermore “gas counting”.

  30. DYNAMIC HEAT LOAD • CMS: 7.5 K Current decreasing during slow discharge Thermosyphon Mass flow is naturally increased due to the higher heat load 4.5 K Temperature increase ~ 0.28 K

  31. DYNAMIC HEAT LOAD • CMS Temperature increase ~ 0.28 K Fast discharge at 5000 A Slow discharge

  32. FAST CURRENT DISCHARGE

  33. FAST CURRENT DISCHARGE • CMS: stored EM energy is 2.5 GJ (about 220 Tons) Temperature rise up to 70 K 1 hour Pressure rise in PS

  34. FAST CURRENT DISCHARGE • ATLAS-CS: Stored EM energy is 40 MJ 1 min

  35. FAST CURRENT DISCHARGE • ATLAS-CS: pressure rise Current: 7800 A Coil return: max 7.11 bar Coil inlet: max 4.32 bar From F.Haug

  36. FAST CURRENT DISCHARGE • ATLAS-BT: Stored EM vs. Enthalpy EM Energy at Current [A] 57 K BT Enthalpy

  37. FAST CURRENT DISCHARGE • ATLAS-BT: 15 min Pressure in Phase Separator Pressure on the return to the Shield Refrigerator

  38. FAST CURRENT DISCHARGE • ATLAS-BT:

  39. FAST CURRENT DISCHARGE • BT: Recovery after a full current fast dump One day 58 K

  40. SummaryData on transient modes of operation have been displayed and discussed, namely:- cooling down process- static heat load- dynamic heat load- fast discharge of the magnets- recovery after a fast dump. The results are in good agreement with the design

  41. I would like to thank for their collaboration all colleagues from CERN and from the external Institutes involved (CEA-SACLAY,INFN,KEK,RAL)