Construction Hazards and Standards

Construction Hazards and Standards. MODULE 21. Construction vs. General Industry. “Construction, alteration and/or repair, including painting and decorating” is under 29 CFR 1926 – 29 CFR 1910.12 Repair of existing facilities; replacement of structures and their components

calder
Download Presentation

Construction Hazards and Standards

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Construction Hazards and Standards MODULE 21

  2. Construction vs. General Industry • “Construction, alteration and/or repair, including painting and decorating” is under 29 CFR 1926 – 29 CFR 1910.12 • Repair of existing facilities; replacement of structures and their components • Interpretation: Construction vs. Maintenance

  3. 29 CFR 1926 Organization • General • General Interpretations • General Safety and Health Provisions • Occupational Health and Environmental Controls • Personal Protective and Life Saving Equipment • Fire Protection and Prevention • Signs, Signals, and Barricades • Materials Handling, Storage, Use, and Disposal • Tools – Hand and Power

  4. 29 CFR 1926 Organization • Welding and Cutting • Electrical • Scaffolds • Fall Protection • Cranes, Derricks, Hoists, Elevators, and Conveyors • Motor Vehicles, Mechanized Equipment, and Marine Operations • Excavations • Concrete and Masonry Construction • Steel Erection

  5. 29 CFR 1926 Organization • Underground Construction, Caissons, Cofferdams, and Compressed Air • Demolition • Blasting and the Use of Explosives • Power Transmission and Distribution • Rollover Protective Structures; Overhead Protection • Ladders • Commercial Diving Operations • Toxic and Hazardous Substances

  6. Hazards and Standards • What hazards are employees exposed to: • When they set up a drilling site? • When they grade land or excavate? • When they clear a site for use? • Regulations in 29 CFR 1926: • Subpart P – Excavations • Subpart O – Motor Vehicles, Mechanized Equipment, and Marine Operations • If blasting: Subpart O

  7. Excavations 29 CFR 1926 Subpart P

  8. Excavation Hazards • Excavating is recognized as one of the most hazardous construction operations • Fatality rate for excavations is twice that of construction as a whole • Cave-ins: More likely to result in fatalities than other excavation hazards

  9. Hazards of Excavation Work • Cave-ins • Underground utilities • Materials/equipment falling into excavation sites • Asphyxiation • Explosion • Falls • Drowning

  10. Soil Mechanics • Unit weight of soils: • Varies with type and moisture content • 1 cubic foot can weigh 100 to >140 lbs • 1 cubic meter can weigh >3000 lbs

  11. Types of excavation collapse

  12. Heaving or Boiling

  13. Definitions • Excavation: any man-made cut, cavity, trench, or depression in an earth surface, formed by earth removal. • Trench (Trench excavation): a narrow excavation (in relation to its length) made below the surface of the ground. • Depth>width; width <15 feet • <15 feet between structure and side

  14. Definition – Competent Person • Training, experience, and knowledge of: • Soil analysis • Use of protective systems • Requirements of 29 CFR Part 1926 Subpart P • Ability to detect: • Conditions that could result in cave-ins • Failures in protective systems • Hazardous atmospheres • Other hazards including those associated with confined spaces • Authority to take prompt corrective measures to eliminate existing and predictable hazards and to stop work when required

  15. 1926.651 Specific Excavation Requirements • Remove or support surface encumbrances (competent person) • Determine location of all underground utilities before opening excavation • OneCall system / 811 • Use safe means to determine exact locations & protect underground utilities

  16. 1926.651(c) Access & Egress • Structural ramps for access and egress designed by competent person & constructed according to design • Bar is higher for equipment ramps • Access & egress ramps designed to avoid slipping or tripping

  17. 1926.651(c) Access & Egress 4' or greater Every 25' • Stairway, ladder, ramp, other safe egress within 25 feet of employees in trenches >4 feet deep • Ladder requirements apply, including extending 3 feet above top surface

  18. 1926.651 Specific Excavation Requirements • In traffic areas, reflective vests required • No workers underneath loads handled by lifting or digging equipment. • Barricades, stop logs or hand signals for mobile equipment operating near excavations

  19. 1926.651(g) Hazardous atmospheres • In excavations 4 feet or more where hazardous atmospheres are likely to exist must test atmosphere before entering and retest as necessary • Unsafe below 19.5% oxygen • Stay below 20% of lower flammable limits • Ventilation or PPE must be used as required • Rescue equipment available

  20. 1926.651(h) Water Accumulation • Precautions required before working for water in excavations • Competent Person must monitor control measures • If diverting surface water, must take steps to prevent water from entering trench

  21. 1926.651(i) Stability of adjacent structures • Structures adjacent to excavations must be supported if stability is affected • No excavation below adjacent footings unless underpinned, or stable rock, or approved by PE • No undermining pavements unless supported

  22. 1926.651 Specific Excavation Requirements • Protect employees from falling rock, soil, or materials/equipment falling into excavations. • Keep materials 2 feet from edge • Retaining devices/barricades • Inspections by competent person, daily and as needed during shift • Walkways to cross excavations

  23. 1926.652 Requirements for protective systems • Protection of employees in excavations • Design of sloping and benching systems • Design of support systems, shield systems, and other protective systems • Materials and equipment • Installation and removal

  24. 1926.652(a) Protection of employees in excavations • Use adequate protective system, except • Excavations entirely in stable rock • <5 feet and competent person sees no potential for cave-in • Capacity for all reasonably expected loads

  25. 1926.652(b) and (c) Design of sloping and benching systems • Four choices for sloping: • Slope for type ‘C’, no steeper than 34° • Use sloping choices from Appendices A, B • Tabulated data determined by a PE • Designed by a PE • For support systems, shield systems, other: • Design using Appendices A, C, D • Manufacturer’s tabulated data • Other tabulated data determined by a PE • Designed by a PE

  26. 1926.652(d) Materials and equipment • Materials for protective systems free from damage & defects • Used according to manufacturer’s specifications • If damaged, competent person must determine suitability for continued use

  27. 1926.652(e) Installation and removal of support • Support system members securely connected together • Installed & removed to assure employee safety • Keep within design capacity • Remove from bottom first, and backfill as you remove

  28. 1926.652(f) Sloping and benching systems • No working on sloped or benched faces unless employees below are protected

  29. 1926.652(g) Shield systems • Shield systems not subject to loads exceeding their capacity • Installed to restrict lateral movement • Employee protection provided while entering/exiting shields • No employees in trench during installation or removal of shields • May excavate up to 2 feet below shield with proper conditions

  30. Trench box Shoring Subtitles & Transitions FOR EXAMPLE… Shielding

  31. 1926 Subpart P Appendix A - Soil Classification • A method of categorizing soil and rock deposits in a hierarchy: • Stable Rock • Type A – cohesive soil >1.5 tsf – with exceptions • Type B – cohesive soil >.5-1.5 tsf or granular, disturbed, vibrated, fissured, layered • Type C – cohesive soil <.5 tsf or granular, submerged, layered…

  32. Soils - Types & Particle Size • Gravel • larger than 2 millimeters • Sand • Between 0.075 and 2 millimeters • Silt • Between 0.002 and 0.075 millimeters • Clay • Smaller than 0.002 millimeters .

  33. Additional soil classification • Layered geological strata: based on weakest layer • May be classified individually if weaker is on top of stronger

  34. 1926 Subpart P Appendix A - Soil Classification • Each soil and rock deposit shall be classified by a competent person • Classification made based on at least one visual and one manual analysis

  35. Visual tests: Particle size

  36. Visual tests • Clumping • Cracks or spalling • Existing utilities/previously disturbed soil • Layers and slope • Water in surface, seeping, water table • Vibration sources

  37. Manual tests • Plasticity • Dry strength • Thumb penetration • Pocket penetrometer or shearvane • Drying test

  38. Motor Vehicles, Mechanized Equipment, and Marine Operations 29 CFR 1926 Subpart O

  39. Organization of Subpart O • 1926.600 - Equipment. • 1926.601 - Motor vehicles. • 1926.602 - Material handling equipment. • 1926.603 - Pile driving equipment. • 1926.604 - Site clearing. • 1926.605 - Marine operations and equipment. • 1926.606 - Definitions applicable to this subpart.

  40. 1926.600(a) Equipment - General Requirements • Lights/reflectors on unattended equipment next to highway • Protection for tire changes on split rims • Elevated equipment: protect from falling • Parking brake, plus chocks for inclines • Batteries: by Subpart K • Cab glass: safety glass with no visible distortion • Movement around power lines or transmitters • Stops for railroad cars on spurs

  41. 1926.601 – Motor Vehicles • Coverage. • Motor vehicles that operate within an off-highway jobsite, not open to public traffic • Not for material handling equipment covered under 1926.602.

  42. 1926.601(b) General requirements • Brake system in operable condition: • Service brake system • Emergency brake system • Parking brake system • 2 headlights & 2 taillights if needed, depending on visibility • Brake lights regardless of visibility

  43. 1926.601(b) General requirements • Audible warning device (horn) • Obstructed rear view: must have • Reverse signal alarm audible above surrounding noise level or • Backed up only when observer signals that it is safe • Windshields & powered wipers on cabs • Fix cracked glass • Defogger/defroster where necessary

  44. 1926.601(b) General requirements • Haulage vehicles: cab shield and/or canopy adequate to protect the operator from shifting or falling materials • Secure tools and material from movement in compartments with employees • Seats firmly secured and adequate for employees being carried

  45. 1926.601(b) General requirements • Seat belts and anchorages meeting 49 CFR Part 571 • Dump bodies supported, locked into position for maintenance or inspection • Latch on hoisting/dumping devices to prevent accidental operation • Trip handle of dump truck tailgate: operator must be clear when dumping

  46. 1926.601(b) General requirements • Rubber-tired equipment must have fenders or mud flaps • Vehicles checked at beginning of shift: • All brake systems • Tires • Horn • Steering • Coupling • Seat belt • Controls • Safety devices • Lights/reflectors • Wipers/defrosters • Fire extinguishers

  47. 1926.602 – Material Handling Equipment • Application: • Scrapers, loaders, crawler or wheel tractors, bulldozers, off-highway trucks, graders, agricultural and industrial tractors, and similar equipment • Compactors and rubber-tired "skid-steer" equipment: reserved

  48. 1926.602(a)(2) Seat belts • Provided and must meet standards • Not necessary for standup operations • Not necessary for equipment without roll-over protective structure (ROPS) or canopy protection • ROPS: See 1926 Subpart W