100 likes | 271 Views
Containment assessment results for ALFRED Results and conclusions (EA). E. Bubelis of behalf of Task 5.6 of LEADER WP5. Model for RADTRAD calculation. 7/171 SAs severely damaged Source term Fission Products: Kr, Xe, I, Sr, Cs, 3 H ENEA Activation: 3 H (CR), 210 Po (Pb) ENEA
E N D
Containment assessment results for ALFREDResults and conclusions (EA) E. Bubelis of behalf of Task 5.6 of LEADER WP5
Model for RADTRAD calculation E. Bubelis – LEADER/ELECTRA Safety Review Workshop, Petten
7/171 SAs severely damaged Source term Fission Products: Kr, Xe, I, Sr, Cs, 3H ENEA Activation: 3H (CR), 210Po (Pb) ENEA 100% release from pins & immediate release Volatilization fractions 800ºC (ULOF) I, Cs, Sr, Po (by KTH) Data & assumptions (1/2) E. Bubelis – LEADER/ELECTRA Safety Review Workshop, Petten
Containment Model Chemical form of Iodine isotopes R.G. 1.183 Irrelevant (No removal) Radionuclide removal from containment only decay and leakage, NO natural deposition, NO spray Primary Containment Leak rate 0.1% d-1 (EUR for LWR, Vol. 2, Rev. C) Dose Conversion Factors FGR-11&12 X/Q need of meteorological data Pitesti (Romania) Reference values for accident condition (Spanish NPP) Data & assumptions (2/2) E. Bubelis – LEADER/ELECTRA Safety Review Workshop, Petten
Activity Released to Environment Noble Gases & Tritium ~1012-1014 Bq (~100%) Lead-soluble FP & AP ~107-1010 Bq (<0.01%) E. Bubelis – LEADER/ELECTRA Safety Review Workshop, Petten
Whole-body dose Xenon & Krypton ~0.1 mSv after 30 days (~100%) 88Kr+135Xe+133Xe (84%) E. Bubelis – LEADER/ELECTRA Safety Review Workshop, Petten
Thyroid dose Iodine & Tritium ~0.03 mSv after 30 days (~100%) 131I+3H+133I (99%) E. Bubelis – LEADER/ELECTRA Safety Review Workshop, Petten
Total Effective Dose Equivalent (TEDE) Noble Gases & Tritium ~0.1 mSv after 30 days (100%) E. Bubelis – LEADER/ELECTRA Safety Review Workshop, Petten
Doses Whole-body, Thyroid & TEDE ~0.04-0.001% of US NRC limits after 30 days E. Bubelis – LEADER/ELECTRA Safety Review Workshop, Petten
Doses – Sensitivity Analysis Whole-body, Thyroid & TEDE X/Q*10 & leakage*10 Source term 100 times higher E. Bubelis – LEADER/ELECTRA Safety Review Workshop, Petten