An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Controls and Electrical Preferred Technologies Advel Power Supplies and ABB Circuit Breakers Steve Pavis PH-DT-DI CERN

  2. Gas Control System Steve Pavis PH-DT-DI CERN

  3. Advel Power Supplies Steve Pavis PH-DT-DI CERN

  4. Technical Requirements (extract from our specification) • Preference is that overall power requirements for an individual system be achieved within a single 19" rack mounting chassis. Where this is not possible, e.g. for the larger systems, then two or more 19" rack mounting chassis may be used provided their outputs can be connected together whilst still maintaining current sharing. • The bidder should state “Comply” or “Doesn’t Comply” against the following requirements for clarity in evaluating offers. • Housing : 19” 3U, 4U or 6U high chassis for Rack mounting • Hot Swappable/pluggable Power Supply modules with Input Voltage: 220VAC Input Frequency :50Hz, Output Voltage: 24VDC and 15VDC versions (see table), arranged in an N+1 or Dual Redundant configuration with Power Sharing. • Efficiency : >= 80% • Ripple & Noise (Acc. to IEC/EN 61204) : <= 50mV p-p • Output Hold up time : 15ms • Deviation due to dynamic load change (Transient Response) : for 60% step load increase, output voltage must not deviate by more than 3V. • Front of Module LEDs for Power Supply Status • Power Fail Signal: Volt free contact to be provided (via terminals on the rear of the chassis) for power fail indication of any power supply module. • AC input terminals and DC output terminals to be provided at the rear of the chassis. • Operating Temperature: 0 - 55 degrees Celcius • CE Marked for compliance to EMC and Low Voltage Directives (Immunity and Emission) Advel PSUs Steve Pavis PH-DT-DI CERN

  5. In addition, the bidder should indicate the following in the offer: • “In rush current" when turning on the power system (for both "no • load" and "full load" conditions) • Level of power factor correction (if provided) • MTBF for each power supply module • Method of power sharing e.g. "Active Current Sharing" (third • wire), or "Passive Current Sharing" (Droop regulation/Slope • Programming). • If current limiting is provided on the 24VDC/15VDC output, • please specify and indicate the level. • Height of the 19” rack mounting chassis which houses the power • modules. Advel PSUs Steve Pavis PH-DT-DI CERN

  6. Responses To Cern Specification Advel PSUs Steve Pavis PH-DT-DI CERN

  7. Responses To Cern Specification continued Advel PSUs Steve Pavis PH-DT-DI CERN

  8. Advel PSUs Steve Pavis PH-DT-DI CERN

  9. LEDs indicate correct current balancing and temperature within good operational limits Output Voltage Adjust +/- 10% (in addition to sense lines) Fan Healthy LEDs 250W 300W 350W 500W Any voltage !! 25W 50W 150W 200W 600W 750W 1000W 2000W Advel PSUs Steve Pavis PH-DT-DI CERN

  10. Advel PSUs Steve Pavis PH-DT-DI CERN

  11. Advel PSUs Steve Pavis PH-DT-DI CERN

  12. PSU Circuit Diagram Steve Pavis PH-DT-DI CERN

  13. ABB Busbar Mounted Circuit Breakers Steve Pavis PH-DT-DI CERN

  14. Pump Variable Frequency Drive shielded from sensitive signals AC Power Distribution Miniature Circuit Breakers Directly Mounted On Busbars (Complete assemby can be done “on the bench” to enable speedy installation) Fieldbusses “Daisy Chained” down the back of the control chassis Rear View Steve Pavis PH-DT-DI CERN

  15. Touch Proof Pluggable System – load free MCBS can be snapped on and off the bus bar assemly under live conditions without risk. ABB Busbar Mounted MCB Solution Steve Pavis PH-DT-DI CERN

  16. Can be clipped under live power conditions Busbars rated to 200A Auxiliary Contact Busbar Phase selection ABB Busbar Mounted MCB Solution Steve Pavis PH-DT-DI CERN

  17. Various Motor Starters available Current measuring modules with LED indicators ABB Busbar Mounted MCB Solution Steve Pavis PH-DT-DI CERN

  18. ABB Busbar Mounted MCB Solution Steve Pavis PH-DT-DI CERN

  19. ABB Busbar Mounted MCB Solution Steve Pavis PH-DT-DI CERN

  20. ABB Busbar Mounted MCB Solution Steve Pavis PH-DT-DI CERN