Thermal test (lab modules). G. Riddone, A. Samoshkin Last update 25- Jul -2011. Complement to the presentation on 14.06.2011. Thermal tests. Investigation of the thermo-mechanical behaviour of the module following: Variation of the ambient temperature
E N D
Thermal test(lab modules) G. Riddone, A. Samoshkin Last update 25-Jul-2011 Complement to the presentation on 14.06.2011
Thermal tests • Investigation of the thermo-mechanical behaviour of the module following: • Variation of the ambient temperature • Variation of the RF structure temperature (PETS and accelerating structures) • Variation of the DB Quadrupole temperature • Validation of the FEA model by comparing results with simulated values
Measurements • Measurement of temperatures and comparison to simulations BE-RF • Measurement of deformations/stresses and comparison to simulation EN-MME (K. Artoos) + BE-RF • Measurement of the RF structure alignment Method to be defined by SU
Power dissipation by T0 Lab Module components 150 W 110 W 410 W 410 W 410 W 410 W 110 W 410 W 410 W 410 W 410 W 110 W 150 W 110 W * DB Q DB Q PETS 440 W DB Q 300 W AS 3280 W * Technical Specification for the CLIC Two-Beam Module G. RIDDONE EDMS 1097388
Heaters for T0 Test Module Max 3050 W max 480 W max 480 W 1600 W 1600 W • - One 80” (2024 mm) long heater for DB (PETS) • One 80” (2024 mm) long heater for MB (AS) • Sixteen 200W cartridges for DB (Quads)
Measurements equipment configuration Prepared by M. Sosin
Thermometers calibration Prepared by M. Sosin • Calibration during slow cooling of heated copper block with all PT100 • Polynomials calculation based on precision reference thermometer BE/ABP Survey equipment will be borrowed
Sequence of the tests Possibility to use IR camera to be investigated
Planning • Accelerating structure and PETS being assembled several steps and learning process • QDB and BPM are available • The aim is to complete the assembly of the first module by end of 2011 • Afterwards thermal tests can start