250 likes | 482 Views
Model-based Automatic AC/PC Detection on Three-dimensional MRI Scans. Babak A. Ardekani, Ph.D., Alvin H. Bachman, Ph.D., Ali Tabesh, Ph.D. The Nathan S. Kline Institute for Psychiatric Research, Orangeburg, NY.
E N D
Model-based Automatic AC/PC Detection on Three-dimensional MRI Scans Babak A. Ardekani, Ph.D., Alvin H. Bachman, Ph.D., Ali Tabesh, Ph.D. The Nathan S. Kline Institute for Psychiatric Research, Orangeburg, NY
The anterior and posterior commissures are bundles of transverse white matter fibers that connect the two cerebral hemispheres
AC PC The AC and PC landmarks are intersection points of these fibers with the mid-sagittal plane
Aim To develop an algorithm for automatic detection of the AC/PC on 3D structural MRI scans
Applications • Orientation of the human brain for computerized image analysis • Definition of coordinate systems in brain atlases (Talairach-Tournoux; Schaltenbrand-Wahren) • Placement and orientation of the imaging FOV in MRI acquisition • Image registration
Example application FOV placement for MRI acquisition
Method • 3D template matching • Normalized cross-correlation (NCC) similarity measure
Template definition AC/PC and MPJ landmarks are manually placed on example images by an expert
Algorithm MRI volume Detect the mid-sagittal plane (MSP) Detect midbrain-pons junction (MPJ) MPJ template AC/PC templates Save AC/PD Detect AC/PC Save MSP Update MSP
MSP detection Ax + By + Cz = 1 Ardekani et al., IEEE Trans. Medical Imaging, 1997.
Algorithm MRI volume Detect the mid-sagittal plane (MSP) Detect midbrain-pons junction (MPJ) MPJ template AC/PC templates Save AC/PD Detect AC/PC Save MSP Update MSP
MPJ detection Candidate MPJ points are detection on a circular search region by template matching using NCC
Algorithm MRI volume Detect the mid-sagittal plane (MSP) Detect midbrain-pons junction (MPJ) MPJ template AC/PC templates Save AC/PD Detect AC/PC Save MSP Update MSP
AC/PC detection The AC/PC are detected based on each possible MPJ location
AC/PC detection The final decision is made by adding the NCC’s of all three landmarks
Algorithm MRI volume Detect the mid-sagittal plane (MSP) Detect midbrain-pons junction (MPJ) MPJ template AC/PC templates Save AC/PD Detect AC/PC Save MSP Update MSP
MRI data • 36 healthy volunteers, 17 patients with chronic schizophrenia (total: 53 scans) • Siemens Vision 1.5T • 3D T1-weighted MPRAGE structural MRI scans • TR=11.6 ms, TE=4.9 ms, =8, Matrix=256×256×190, 1 mm3 voxels
Template definition 3 patient (top row) and 3 control (bottom row) scans were used to construct templates for AC/PC and MPJ
Results Qualitatively correct AC/PC locations were detected on 52 of the 53 cases.
Results The 1 scan on which the algorithm failed
Results 5 of 53 scans had severe artifacts
Results Processing time: 6 s on Pentium 4, 3.2 GHz (4.5 s MSP detection + 1.5 s AC/PC detection); 2 s on Quad Core Intel Xeon E5430, 2.66 GHz
Results: Manual vs. automatic detection 3D Euclidean distance (error) between manually and automatically detected AC/PC in 42 scans (53-6-5=42)
Summary • Fast, accurate, robust, and fully automatic AC/PC detection • Algorithm can be trained for contrasts other than T1 (e.g., T2-weighted FSE) • Algorithm shows robustness with respect to field strength, pulse sequence parameters, subject population • Available on www.nitrc.org