Guyana Standards RC10/SC15/2009/C2 Code of Practice for the design and construction of Ventilated Improved Pit (VIP) Latrines as a sanitary household solution for human excreta Guyana National Bureau of Standards. VIP Latrine. Isolation of human excreta Comfort, privacy
E N D
Guyana StandardsRC10/SC15/2009/C2Code of Practice for the design and construction of Ventilated Improved Pit (VIP) Latrinesas a sanitary household solution for human excretaGuyana National Bureau of Standards
VIP Latrine • Isolation of human excreta • Comfort, privacy • Elimination of vectors (flies, rats, etc)
Calculations V = K x N x T • V = effective volume in m3 • K = Rate of sludge accumulation (m3/pers/year) k=0.04 in wets pits and 0.06 in dry pits • N = Number of people using pit • T = Design life (years)
Calculations D = V /As + Fb • D = Depth of Pit • V = Effective volume in m3 • As = Cross sectional area of pit • Fb = Free board (0.5 m)