ErP & Energy labeling A new age for Thermal Comfort. Index. Legislation context ErP / Labeling ( summary ) Solid fuel boilers ( Lot 15) Boilers ( Lot 1) Water heaters ( Lot 2). The legislation context. (20/20/20) EU Target on energy consumption not completely reached….
E N D
ErP & Energy labeling A new age for Thermal Comfort
Index Legislation context ErP/Labeling (summary) Solid fuelboilers (Lot 15) Boilers (Lot 1) Water heaters (Lot 2)
The legislationcontext (20/20/20) EU Target on energy consumption not completely reached… …New / Existing portfolio measures to be adopted/ integrated by countries (with local specificities) Main laws & their upgrades (to be nationally adopted) In line with 2020 target Incoming… (at the same time for all countries) NOT in line with 2020 target
The legislationcontext • Policiesforsustainablegrowth Before 2002 Mainlegislations entered into force 2002 2008 2012 2014 2016 ERP Regulation Air Quality Dir. EPBD Recast & 2008/50/EC 2010/31/EC Labelling EPBD Dir. RES Directive EED Dir. 2002/91/EC 2009/28/EC Main EU laws and relatedmessages 2012/27/EU Dwellings Products Services • Energy labels • Reqs on new, butalsoRenovationreqs start tobeadopted • RES obligation (New) • Districtheatingpromoted • Smart meters & Building AutomationControlSystems • Localelectricity generation (PV, Mchp) • Nearly Zero Energy buildings • Energy / Qualitylabels • Minimum techn. system performances (New/Retro) – banof low efficientproducts (i.e. EWH) • RES obligation (New) • RES promotion (Retro) – incentive schemes • PeriodicalSysinspection • Emissionlimits in urbanareas • PA asexample (purchaseonly HE products) • Istallersqualifications / energy audits • Utilities energysavingstargetsenhanced • Energy savingsmarkets (whitecertificates) development • Renewableenergiesmarkets (green certificates) • ESCO’s promotion • Hourlyenergytariffs (Smart Grid)
ErP/Labeling - summary ErP Labeling EuropeanRegulations (implementingmeausures of 2009/125/eu Directive; valid in the wholeEuropean Union, withoutnationaladoptons, variations, delays etc.) What are they? Binding to bear the EC mark ENERGY RELATED PRODUCTS (ErP) (Thermal confort technologies) Boilers, Water heaters, Air conditioners, Heatpumps, storage tanks, ventilators, circulators… supplied by electricity, gas, oil, solidfuels, liquidfuels etc. Technologies havebeeninitiallygrouped in differentLotsleading to specificimplementingmeasures Coveredproducts Minimum energy Performances + Environmentalrequirements (emissions, noise, dismantling etc.) differentby technologies Energy labels (products & packages) Technical fiches(products& packages) Technical/promotionalmaterialsincludingenergy performance info Whattheyestablish?
ErP/Labeling - summary ErP Labeling EuropeanRegulations (implementingmeausures of 2009/125/eu Directive; valid in the wholeEuropean Union, withoutnationaladoptons, variations, delays etc.) What are they? Binding to bear the EC mark • SUPPLIER(product’sresp on the market) • Places on the market productsErP-compliant; • Places on the market productsprovided with: • (productand/or package) Energy labels; • (productand/or package) Technical fiches; • Technical advertisements or promotions with info aboutproduct/package energyclass; DEALER The exhibited devices or packages are equipped with the respective labels, In case it is not expected for the end user to see the exhibited device, this is sold together with the information on energy efficiency; Technical advertisements or promotions with info aboutproduct/package energyclass; Resp.ties
Solid fuel boiler ErP/Labeling regulation: Timing In progress Regulatory Committee June-July 2014 2022 ?? (2018?) 10.03.14 Compromise on ErPrequirements for solid fuel boilers (Lot 15) and solid fuel local space heaters (Lot 20) has been reached. The Energy Labellngwas not discussed at this meeting. Expected vote in the Regulatory Committee on Ecodesign requirements • Ecodesign requirements entry into force • Efficiencies • Emissions Ecodesignreqs (Boilers) P ≤ 1.000 kW (Local) P ≤ 50 kW SF - Boilers - Local SH Label mandatory Labeling (Boilers) P ≤ 70 kW (Local) P ≤ 50 kW
Solid fuel boiler ErP/Labeling regulation: requirements In progress Solid fuel local space heaters (Lot 20) Solid fuel boilers (Lot 15) By 2022 By 2022 By 2022 By 2022 Emissions
Solid fuel boiler ErP/Labeling regulation: labelling In progress Solid fuel local space heaters (Lot 20) Solid fuel boilers (Lot 15) I. supplier’s name or trade mark; II. supplier’s model identifier; III. the energy efficiency class,; IV.- V. the symbol for direct heat output symbol and its value in kW, VI.- VII. for local space heaters with heat transfer to a fluid the symbol for indirect heat output and its value in kW, I. supplier’s name or trade mark; II. supplier’s model identifier; III. the space heating function; IV. the energy efficiency class, V. the rated heat output in kW, VI. for combination boilers, the water heating function. Package label
ErP/Labeling – Space Heaters & Water heaters ErP Labeling EuropeanRegulations (implementingmeausures of 2009/125/eu Directive; valid in the wholeEuropean Union, withoutnationaladoptons, variations, delays etc.) What are they? Binding to bear the EC mark Minimum energy Performances + Environmentalrequirements (emissions, noise, dismantling etc.) differentby technologies Energy labels (products & packages) Technical fiches(products& packages) Technical/promotionalmaterialsincludingenergy performance info Whattheyestablish? BOILERS (gas, electrical, oil) HEAT PUMPS(gas, electrical, oil) mCHP (≤ 50 kW electricalpower) WATER HEATERS (gas, elettrici, oli) RENEWABLE WHs(solar / HPWH) HOT WATER STORAGE TANKS Coveredproducts P ≤ 400 kW P ≤ 70 kW V ≤ 2.000 lt V ≤ 500 lt
Dates of adoption & main contents – Space Heaters Entry into force 26.09.15 26.09.17 26.09.18 26.09.19 26.09.13 Boilers HP Mchp Label mandatory Classes: A++ / G Update Intro new classes Labeling (P < 70 Kw) Minimum Perf (P < 400 kW) Second tier Only for HP First tier “Only HE”. 56 mg/kWh (gas) 120 mg/kWh (oil) Others (mCHP, GAHP) Other requis (P < 400 kW) Sound level Only for HP ≤ 6 kW NOx
Dates of adoption & main contents – Water Heaters Entry into force 26.09.15 26.09.17 26.09.18 26.09.19 26.09.13 Update Intro new classes WH HPWH Label mandatory Classes: A / G Labeling (P < 70 Kw) Minimum perf (P < 400 kW) First tier ‘light’ Second tier ‘serious’ Third tier Only for big capacity WH 56 mg/kWh (gas) 120 mg/kWh (oil) Others (mCHP, GAHP) Other reqs. (P < 400 kW) Sound level Only for HP <=6 kW NOx Performance limits Only for V < 2.000 l) Label mandatory (Only for V < 500 l) Storage tanks
Dates of adoption & responsibilities Regulations will only apply to products’ on the market since 26/09/2015; those purchased before that date, and already available in sale points or distributors’ warehouses, will continue to be sold and installed, even though they are not in compliance with the new standards. by 26/09/2015… • SUPPLIER(product’sresp on the market) • Places on the market productsErP-compliant; • Places on the market productsprovided with: • (productand/or package) Energy labels; • (productand/or package) Technical fiches; • Technical advertisements or promotions with info aboutproduct/package energyclass; DEALER The exhibited devices or packages are equipped with the respective labels, In case it is not expected for the end user to see the exhibited device, this is sold together with the information on energy efficiency; Technical advertisements or promotions with info aboutproduct/package energyclass;
Product and Package Labels: the principle PACKAGES Package label can be filled by the supplier and by the dealer (distributor, installer, …). It must be exhibited to the end user; Products Product’slabelisprovided by supplier Dealer (i.e. distributor, installeretc.).has to exhibit the label; Solar tank Solar collector Thermo-regulatingdevice Supplementaryheater Supplementaryheater
Product and Package Labels: description HHP EWH Differentlabel’s layout by technologies, but the sameenergyclasses: comparability