11073 in CDA Representing anaesthetic vital sign data in a CDA document, using the 11073 standard. Martin Hurrell Alan Nicol. Acknowledgements. In no particular order thanks to: Terri Monk (IOTA & HL7 Anesthesiology WG)) John Rhoads and Jan Wittenber (HL7 Healthcare Devices WG).
E N D
11073 in CDA Representing anaesthetic vital sign data in a CDA document, using the 11073 standard • Martin Hurrell Alan Nicol
Acknowledgements In no particular order thanks to: Terri Monk (IOTA & HL7 Anesthesiology WG)) John Rhoads and Jan Wittenber (HL7 Healthcare Devices WG)
Anaesthetic vital signs use case (Setup) Vital Signs Monitoring Setup Connect the various probes and measurement devices to a patient so that their physiological values can be measured and recorded during an intra-operative procedure. Scenario A blood pressure cuff is placed on the left upper arm of the patient and connected to the patient monitors non-Invasive blood pressure module. The non-invasive blood pressure module uses a sphygmomanometric technique to measure systolic and diastolic blood pressure. Blood pressure values are typically measured in millimetres of Mercury (mmHg). Actors Patient: A person who is the recipient of healthcare services. Patient Monitor: an electronic medical device that measures and displays a patient's vital signs
Anaesthetic vital signs use case (Recording) Vital Signs Monitoring Recording The context is the measurement and storage of physiological values from a patient during a surgical procedure under anaesthesia. In the following example the values recorded are the patient’s non-invasive blood pressures. Scenario Monitoring starts and the first set of values of the Systolic, Mean and Diastolic blood pressures are collected after an initial interval of 5 minutes and at 5 minute intervals thereafter. Actors Patient: A person who is the recipient of healthcare services. Patient Monitor: an electronic medical device that measures and displays a patient's vital signs
11073 Dim Patient monitor/Blood Pressure Module
11073 Dim Patient monitor/Blood Pressure Module Non-Invasive Blood Pressure
11073 Dim Patient monitor/Blood Pressure Module Non-Invasive Blood Pressure Blood Pressure Measurement
11073 to HL7 R-MIM VMD (Patient Monitor)
11073 to HL7 R-MIM Channel (Non-Invasive Blood Pressure) VMD (Patient Monitor)
11073 to HL7 R-MIM Channel (Non-Invasive Blood Pressure) Metric(Blood Pressure Measurement) VMD (Patient Monitor)
11073 to CDA R-MIM VMD (Patient Monitor)
11073 to CDA R-MIM Channel (Non-Invasive Blood Pressure) VMD (Patient Monitor)
11073 to CDA R-MIM Channel (Non-Invasive Blood Pressure) Metric (Blood Pressure Measurement) VMD (Patient Monitor)
11073 to CDA Example (Recording) • <observation> • <entryRelationship typeCode="COMP"> • <observation classCode="OBS" moodCode="EVN"> • <id extension="67" root="2.16.840.1.113883.6.1" assigningAuthorityName="HL7 GAS WG" displayable="true"/> • <code code="19229" codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="MDC_PRESS_CUFF_SYS"/> • <entryRelationship typeCode="COMP"> • <observation classCode="OBS" moodCode="EVN"> • <effectiveTime value="20080527074500"/> • <targetSiteCode code="1781" codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="MDC_UPEXT_ARM_UPPER_L"/> • <statusCode codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="validated-data"/> • <value code="3872" codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="MDC_DIM_MMHG" value="119"/> • </observation> • </entryRelationship> • </observation>
11073 to CDA Example (Recording) Channel (Non-Invasive Blood Pressure) • <observation> • <entryRelationship typeCode="COMP"> • <observation classCode="OBS" moodCode="EVN"> • <id extension="67" root="2.16.840.1.113883.6.1" assigningAuthorityName="HL7 GAS WG" displayable="true"/> • <code code="19229" codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="MDC_PRESS_CUFF_SYS"/> • <entryRelationship typeCode="COMP"> • <observation classCode="OBS" moodCode="EVN"> • <effectiveTime value="20080527074500"/> • <targetSiteCode code="1781" codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="MDC_UPEXT_ARM_UPPER_L"/> • <statusCode codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="validated-data"/> • <value code="3872" codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="MDC_DIM_MMHG" value="119"/> • </observation> • </entryRelationship> • </observation>
11073 to CDA Example (Recording) Channel (Non-Invasive Blood Pressure) • <observation> • <entryRelationship typeCode="COMP"> • <observation classCode="OBS" moodCode="EVN"> • <id extension="67" root="2.16.840.1.113883.6.1" assigningAuthorityName="HL7 GAS WG" displayable="true"/> • <code code="19229" codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="MDC_PRESS_CUFF_SYS"/> • <entryRelationship typeCode="COMP"> • <observation classCode="OBS" moodCode="EVN"> • <effectiveTime value="20080527074500"/> • <targetSiteCode code="1781" codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="MDC_UPEXT_ARM_UPPER_L"/> • <statusCode codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="validated-data"/> • <value code="3872" codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="MDC_DIM_MMHG" value="119"/> • </observation> • </entryRelationship> • </observation> Metric (Blood Pressure Measurement)
11073 to CDA Example (Setup) • <organizer classCode="CLUSTER" moodCode="EVN"> • <participant contextControlCode="OP" typeCode="DEV"> • <participantRole classCode="ROL"> • <id extension="23" root="2.16.840.1.113883.6.1" assigningAuthorityName="HL7 GAS WG" displayable="true"/> • <id extension="1.3.2" root="2.16.840.1.113883.7.1" assigningAuthorityName="GE Healthcare" displayable="true"/> • <playingDevice classCode="DEV" determinerCode="INSTANCE"> • <code code="4429" codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="MDC_DEV_MON_PHYSIO_MULTI_PARAM_MDS"/> • <manufacturerModelName displayName="GE8001i"/> • <softwareName displayName="1.2.3"/> • </playingDevice> • </participantRole> • </participant>
11073 to CDA Example (Setup) • <organizer classCode="CLUSTER" moodCode="EVN"> • <participant contextControlCode="OP" typeCode="DEV"> • <participantRole classCode="ROL"> • <id extension="23" root="2.16.840.1.113883.6.1" assigningAuthorityName="HL7 GAS WG" displayable="true"/> • <id extension="1.3.2" root="2.16.840.1.113883.7.1" assigningAuthorityName="GE Healthcare" displayable="true"/> • <playingDevice classCode="DEV" determinerCode="INSTANCE"> • <code code="4429" codeSystem="1.3.6.1.4.1.19376.1.6" codeSystemName="ISO/IEEE 11073" codeSystemVersion="10201" displayName="MDC_DEV_MON_PHYSIO_MULTI_PARAM_MDS"/> • <manufacturerModelName displayName="GE8001i"/> • <softwareName displayName="1.2.3"/> • </playingDevice> • </participantRole> • </participant> VMD (Patient Monitor)