Part III ILC BCD Cavity

Part III ILC BCD Cavity. Maximum Use of Potential Performance Maximum Use of each Cavity Performance Maximum Availability. Problems of Cavity for ILC Application. Large Scatter of Maximum Gradient Large Dynamic Lorentz Detuning Long MTBF for Critical Components

chaela
Download Presentation

Part III ILC BCD Cavity

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Part IIIILC BCD Cavity • Maximum Use of Potential Performance • Maximum Use of each Cavity Performance • Maximum Availability Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  2. Problems of Cavityfor ILC Application • Large Scatter of Maximum Gradient • Large Dynamic Lorentz Detuning • Long MTBF for Critical Components > 20 years --- < 5 %/year • Maximum Use of Potential Performance • Maximum Use of each Cavity Performance • Maximum Availability Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  3. Common Numbers are necessary • Number of Spare Cryomodules < 30 • How many modules can we replace in a scheduled shutdown ? • MTBF / Life Time ? • How many critical component in a cryomodule ? • Number of cavities to be repaired in a year < ? • How is the lowest gradient we have to operate ? • Distribution of the Max. Gradient Where do we set the threshold gradient ? Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  4. ILC BCD Cavity Parameters Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  5. DESY Cavity SupportSystem is weak. Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  6. Scatter of Maximum Gradient Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  7. Gradient Distribution First Test Before Installation After Installation Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  8. Lorentz ( Maxwell ) Detuning Kjacket Ktuner Fr Kcavity F F Fz Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  9. Mechanical Oscillation Modes 972MH Cavity Multi-cell Mode (I) f = 87 Hz Tuner Multi-cell Mode (II) f = 169 Hz Tuner Mode f = 294 Hz Single-cell Mode f = 3.91 kHz Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  10. Stiff Jacket Baseplate (Ti) 2.8 t 3.5 t Thick Titanium Baseplate No Stiffener Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  11. Dynamic Lorentz Detuning Results at TTF DPkly < 10 % →Detuning angle < 12 deg. , Df < 46Hz Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  12. TTF Lever Arm Tuner Top Heavy Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  13. TTF Blade Tuner Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  14. Slide Jack Tuner Drive Shaft Invar Rod Piezo Stack Taper Roller Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  15. Tuner and Jacket Motor Outside Piezo Replacement OK 2K He Line Invar Rod Support Base Titanium Jacket Drive Shaft Slide Jack Piezo Stack Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi Input Coupler Port

  16. A prototype coaxial ball screw tuner Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  17. Input Coupler Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  18. TTF-3 Coupler Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  19. Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  20. Input Coupler for Baseline Cavity An improved input coupler design for simplicity with no tuning mechanism. TRISTAN Type Coaxial Disk Ceramic Warm window Cold window Beam pipe 5K cooling here Door-knob conversion 80K cooling here Vacuum port 80 K 5 K 2 K Static Loss 5 W 1.1 W 0.05 W Dynamic Loss 3 W 0.2 W 0.03 W Qext = 2.0 x 106 Prf = 350 kW Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  21. Coupling Waveguides Components for High Power Test Stand Input Couplers Doorknobs Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  22. Coupler Opening Piezo can be replaced Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  23. HOM Coupler Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  24. Gradient Control Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  25. Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  26. Cavity Voltage Error & Gain Reduction Input Power Error Coupling Error Tuning Error Phase Error Beam Phase Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  27. Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi

  28. Hayama ILC Lecture, 2006.5.23, Shuichi Noguchi