1 / 15

BEECO ACV PRESENTATION

BEECO ACV PRESENTATION. Main Applications. Level Control. Pressure Control. Pump Control. Electronic Control. Flow Control. Safety Valves. LADWP Project. What are Beeco ’ s ACV main differentiators? Better Performance:

chelseaa
Download Presentation

BEECO ACV PRESENTATION

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BEECO ACV PRESENTATION

  2. Main Applications Level Control Pressure Control Pump Control Electronic Control Flow Control Safety Valves

  3. LADWP Project

  4. What are Beeco’s ACV main differentiators? • Better Performance: • Better pressure control at very low flows and at very high flows. Larger flow range. • Lower Cost of Ownership: • Reliability – Better materials being used as standard. • Maintainability – Simpler structure than competitors. • Shelf Life – More resistance to cavitation, where others fail. • Wider Control Solutions Range • Extensive Support: • Design phase: consultation in control application selection and valve type selection • After sale support

  5. Performance: Stable regulation at low flowsOur competitors use inferior solutions at low flows: V-Port (V or U shape) Small diam. By-Pass Reduced Port

  6. Beeco uses a patented and superior solution for low flow regulation which: • Does not requires by-pass • Does not affect the valve when fully open (like V-port)

  7. Beeco ACV Low-Flow stability solution: FULLY OPEN REGULATING Low pressure-losses when fully open • Able to regulate at near zero flow rate. • No need for V-Port • No need for by-pass

  8. These two valves can regulate the same low flow!

  9. Low cavitation index will enable safe operation under high pressure differential and low operation noise. • Beeco ACV valves were tested for cavitation by the hydraulic laboratory of Utah State university. Performance: Cavitation Index

  10. Low Cost of Ownership: • Easy maintenance and service (trim is pulled upwards) • Low weight internal trim • No need for special tooling • No periodic parts replacement, greasing etc. • Self-flushing control filter • Same standard valve used for low and high flow • Standard internal SST internal trim (up to 200mm) • No preventive maintenance (just periodic inspection at long intervals) Long term operation with minimal operational costs!

  11. Control Solutions: • A full range of hydraulic control solutions using a wide variety of control devices • Pressure Control applications • Flow control application • Water level control solutions • Safety and protection devices for water-supply systems, pumping systems etc. • Water hammer\Surge prevention & attenuation • Automated & Remote control of the hydraulic parameters Hyd. Control Solutions

  12. Pre-Sale Support: Design phase assistance in: • Hydraulic control solution selection • Supplying computerized, Water-Hammer\Surge analysis • Tailoring the solution to the specific requirements Support

  13. Enquiry (end customer or engineer/designer) Intake, Questionnaire, Gathering of Information Technical Considerations, Data Calculations, Software Simulation Solution Specification & Draft Layout Provision of Valve Solution

  14. Additional Support: • Training programs • Technical back-up • One stop shop for a wide variety of supplementary devices Support