Medzer Biphasic Defibrillator BDFM-1000E offers a user-friendly AED interface with voice alarms, a biphasic waveform, and charges in under 7 seconds. It provides 65-hour data storage and measures electrode impedance across a range of 0 to 250 ohms.
E N D
Biphasic Defibrillator BDFM-1000E www.medzer.com | info@medzer.com
Overview Biphasic Defibrillator BDFM-1000E is multi-parameter device with voice alarm. It uses biphasic wave form to measure the selected parameters. Equipped with user friendly automated external defibrillators (AEDs) interface. Smart alarms with beeper/voice prompts to indicate shockable rhythm Specifications : Energy selection 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 J Charging time 3 hours minimum of continuous ECG monitoring Display 8-inch LCD, high resolution Sweep Speed 25 mm/sec
Defibrillator Waveform Biphasic (BTE) Charge Time Less than 7 seconds with a new fully charged battery Energy Display Monitor display indicates both selected and delivered energy Electrode impedance measurement range 0 to 250 ohms
ECG Lead selection Displayed on monitor, paddles I, II, III, AVR, AVL, AVF, V Lead ECG cable 3-lead or 5-lead ECG cable paddles ECG size 0.25, 0.5, 1, 1.5, 2 4 cm/mV 20 to 300BPM Heart rate Heart rate Alarm On/Off displayed on monitor, user- selectable Smart Alarms Beeper/voice prompts indicate shockable rhythm
SpO2 Measurement range 30 to 100%, ±2% between 80% to 90%, others ±5% Alarm range User can set high limit and low limit Alarm accuracy ±10% within setting values < 12 sec Alarm time accuracy Pulse Oximeter
NIBP Method Automatic oscillation Working mode Manual/automatic Measurement range Adult: 10 to 250mmHg Paediatric:10 to 200mmHg Neonatal: 10 to 135mmHg CO2 CO2 Range 0 to 13% (0 to 98.8mmHg at BTPS) CO2 accuracy < 5.0% CO2 (± 3 mmHg at BTPS) Breath Rate 3 to 60 BPM ±1BPM Measurement accuracy
Pacemaker Pulse type Rectangular, constant current Pulse amplitude 0 to 180 mA, ± 10% or 5 mA Pacing Rate Variable from 30 ppm to 180 ppm ±1.5% Multi- Function Electrode Multipurpose defibrillation/pacing electrode Pause Pacing pulse frequency reduced by a factor of 4 when activated
Printer Paper 50 mm thermal Speed 2.5mm/sec 25mm/sec 50mm/sec Printing Method High-resolution thermal print head Print-out Modes Manual or automatic On/Off Control Front panel and paddle Automatic Function 9-seconds recording initiated by alarm activatio
AED Mode AED Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts Function Shockable Rhythms Ventricular fibrillation with amplitude ≥ 200 µV ventricular Tachycardia with rates ≥ 140 bpm QRS complex wave duration ≥ 140 m Charge Control Control on device front panel press key on paddle Prompts Voice and visual prompts Manual Mode Synchronizes defibrillator pulse to patient’s R- wave. “SYNC”