1 / 99

Chapter 6 NEMA Products Training Session

SMF Fractional HP Manual Motor Starter Page 6/3 to 6/4. SMF Fractional Motor Starters. Class SMF Fractional HP Starters are provided with Melting Alloy Overloads, and the used on AC single-phase motors up to 1 HP.Manual Starters are used when the motor is in sight of the controller (Guideline @ 50ft.)Applications: Fans, conveyors, pumps and small machine tools. .

chick
Download Presentation

Chapter 6 NEMA Products Training Session

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


    3. SMF Fractional Motor Starters Class SMF Fractional HP Starters are provided with Melting Alloy Overloads, and the used on AC single-phase motors up to 1 HP. Manual Starters are used when the motor is in sight of the controller (Guideline @ 50ft.) Applications: Fans, conveyors, pumps and small machine tools.

    4. Fractional Horsepower Manual Starters Product Class SMF: Open Type NEMA Type 1B General Purpose Flush Mounting (No Enclosure Provided) NEMA Type 1 General Purpose Enclosure, Surface Mounting. NEMA Type 3R, 4, & 12

    5. SMF Fractional Horsepower Manual Motor Starters

    7. MMS & MRS Manual Switches Class MMS & MRS Fractional HP Switches provide ON-OFF control where overload protection is not required. These switches are rated for use on 3-phase motors up to 10 HP @ 460V. Manual Switches are used when the motor is in sight of the controller (Guideline @ 50ft.) Applications: Fans, conveyors, pumps and small machine tools.

    8. Fractional Manual Switches Product Class MMS & MRS: Open Type NEMA Type 1B General Purpose Flush Mounting (No Enclosure Provided) NEMA Type 1 General Purpose Enclosure, Surface Mounting. NEMA Type 3R, 4, & 12

    9. MMS & MRS Fractional Horsepower Switches

    11. Manual Starters & Switches Product Class 11 Family: Open Type 3RV NEMA Type 1 NEMA Type 7 & 9 Class I Flammable gasses may ignite Group C & D list of chemicals Class II Combustible dust Group E, F & G list of metals, carbons, grain NEMA Type 3 & 4, NEMA Type 7 & 9

    12. Manual Starters & Switches

    13. Manual Starters & Switches

    14. Manual Starters & Switches

    15. Manual Starters & Switches Across the line provide local control only. 1Ø, 2Ø or 3Ø up to 15HP @ 460 V Ambient compensation Bimetal prevents nuisance tripping Built-in Phase loss trip, protects Motors Can be used for Type E application (self-protected Combo Starter). Saves Money!

    16. Manual Starters & Switches LVP low voltage protection optional. Reduces Potential injuries. Meets OSHA ON/OFF handle lock out with visible trip indicator. Prevents unauthorized entry Short Circuit trip at 13 times FLA for rated current. Test trip function. UL listed CSA Certified, and CE

    17. Product Nomenclature

    18. Manual Starters & Switches Applications include: Grinders Power Saws Conveyors Fans Pumps Blowers Machinery

    19. Manual Starters & Switches Field Modifications LVP mounted on the right Shunt trip mounted on the right Front Plug-in or side mounted Auxiliary Contacts Pilot lights for NEMA 1 only Red, Green or Amber, 24-600V

    20. Manual Starters & Switches

    21. Manual Starter

    22. Open Contactors & Starters

    23. Overload Relays What is the Difference: Between A Short Circuit & An Overload ?

    24. Overload Relays What Is A Short Circuit? An Extreme Amount Of Current Usually Caused By A Fault To Another Phase Or To Ground. Fault Currents Can Exceed Several Thousand Amps For A Very Short Period Of Time Which Can Cause Very Extensive Equipment Damage. Fault Currents May Even Reach Up To 200,000 Amps On Some Systems.

    25. Overload Relays What Is An Overload? 1. An Operating Condition Where The Load Current Exceeds Normal Operation. 2. A Motor That Is Overloaded May Draw 6 Times Its Normal Operating Current (Full Load Current). 3. An Overload For Even Several Minutes May Cause Severe Motor Damage.

    26. Overload Relays What Are The Differences Between … A Fuse Or A Circuit Breaker And An Overload Relay?

    27. Overload Relays Short Circuit Protection Devices Fuses - One Time Use Only Magnetic Circuit Breakers - Reusable After Reset Overload Protection Devices Time Delay Fuses -One Time Use Only Overload Relays - Able To Reset Thermal Magnetic Circuit Breakers - Also Able To Reset

    28. Overload Relays How Overload Relays Work Monitors Over-current Condition On Motor Power Leads Indirectly Thermal Type Overload Relay Directly Magnetic or Electronic Type Overload Relay Turns Off Control Circuit During Overload Condition OL Relay NO Contact Turns Off Motor Starter Coil Circuit

    29. Overload Relays

    30. Bimetal Overload

    31. Bimetal Temp Comp. OLR

    32. Electronic OLR

    33. Electronic OLR

    34. OLR Class 10, 20, 30

    35. Motor Starter Circuit

    37. Enclosed NEMA Starters Product Lines

    39. Enclosed NEMA Starters Non-Combination Starter Products

    40. Enclosed NEMA Starters Non-Combination Starter - Features and Benefits Heavy Duty Industrial Construction Enclosure Types: NEMA 1 Lift-Off Type “Clamshell” (Manufactured with TOX process) NEMA 1, 4x, 7&9, 12 (field convertible to 3/3R) Hinged Standard Width and Extra Wide Enclosures Removable Door/Cover Siemens offers ten NEMA Size Starters from Size 00 up to Size 8 rated 900HP 600V. Siemens also offers three Heavy Duty Half-Size Starters in 1 ¾, 2 ½ & 3 ½ for Cost and Space Savings. Overloads - ESP100 and Bimetal Ambient Compensated Pilot Device Mounting Holes in enclosures

    41. Enclosed NEMA Starters Non-Combination Starter - Features and Benefits Factory & Field Modifications Pages 6/71 to 6/87. Control Power Transformer (CPT) Pilot Devices Control Relays Control Fuses Auxiliary Contacts Meters (Hinged Enclosures Only) Terminal Blocks Etc…

    42. Enclosed NEMA Starters Non-Combination Starter Nomenclature

    43. Enclosed NEMA Starters NEC Requirement for Combination Starter

    45. Enclosed NEMA Starters Combination Starter Products

    46. Enclosed NEMA Starters Combination Starter Products

    47. Enclosed NEMA Starters Combination Starter Products

    48. Enclosed NEMA Starters Combination Starter Products

    49. Enclosed NEMA Starters Combination Starter Products

    50. Enclosed NEMA Starters Combination Starter - Features and Benefits Heavy Duty Industrial Construction Manufactured with TOX process on Most Enclosures Standard Width and Extra Wide Enclosures Four Enclosure Types: NEMA 1, 4x, 7&9, 12 (field convertible to 3/3R and 4) Removable Door Disconnect Types are Field Convertible to Fusible Disconnects 100KA Amp Fault Protection with Class R Fuses to 600V or MCP (Mag Only) to 480V Panel Pre-Drilled for 230V or 600V Fuses

    51. Enclosed NEMA Starters Combination Starter - Features and Benefits Up to 900HP 600V - NEMA Size 8 with ESP100 Solid State Overload Relay Half Size Starters for Cost and Space Savings Overloads - ESP100 and Bimetal Ambient Compensated White Mounting Panel Pre-Drilled for CPT, Relays, Primary Fuse Kit, Pilot Device Mounting Holes in enclosures

    52. Enclosed NEMA Starters Combination Starter - Features and Benefits Factory & Field Modifications Control Power Transformer (CPT) Pilot Devices Control Relays Control Fuses Auxiliary Contacts Meters Terminal Blocks Etc…

    53. Enclosed NEMA Starters Combination Starter Nomenclature

    54. Enclosed NEMA Starters Applications Pumps Fans Material Handling & Conveyor Systems Machine Tools HVAC Equipment Compressors Construction Projects Used in Commercial and Industrial facilities

    55. Enclosed NEMA Starters Options/Modifications - Definitions Page 6/83 to 6/87 covers Factory Modifications that are added to the product, per sales order, at the Siemens factory or distribution Center. Page 6/71 to 6/81covers Field Modifications that are added to the product by distributor/customer with standard catalog field mod kits. This applies to both pre and post installation of base product.

    56. Enclosed NEMA Starters Field Modification Kits

    57. Enclosed NEMA Starters Field Modification Kits

    58. Enclosed NEMA Starters

    59. Half Sizes

    60. NEMA Sizes

    61. NEMA Starter Family up to size 4

    62. Open NEMA Starter

    63. Open Starter Features

    64. ESP100 Electronic OLR True phase loss protection Overload trips within 3 seconds on phase loss, even on lightly loaded motors (60% of minimum dial setting) Customer Benefit: Saves Motors!!! Thermal overloads just can’t provide this degree of protection

    65. Electronic OLR Heaterless Construction No heaters to install, stock, or maintain Customer Benefit: Heaters require time and labor to install

    66. ESP Self - Powered Generates its own low voltage control power through the same sensors that read motor current Customer Benefit: Separate 120VAC control power is not required

    67. ESP100 OLR Ambient Insensitive Overload not affected by temperature, rated -30 °C to 70 °C Customer Benefit: No nuisance tripping on hot days. No open panel doors with fans blowing on controls.

    68. ESP100 OLR 99% of heat generated by thermal overload removed Customer Benefit: Other electronic equipment in panel runs cooler, energy savings. More equipment could go into panel due to lower heat rise.

    69. ESP100 OLR Energy Savings Thermal overloads generate 9 to 24 watts per relay Based on 10 watts per overload and $0.10 per kW/hr, ESP100 will save $7.88 per year in energy costs This can really be significant if user has hundreds of starters!!!

    70. ESP100 ORL Self protected from short circuits Upon the event of a short circuit, the current transformers saturate before any damage is done to the overload Customer Benefit: No need to replace overload relay or heater elements after a short circuit as is required with thermal overloads

    71. ESP100 OLR ± 2 % repeat accuracy Customer Benefit: Under the same conditions, trip time on the overload will be the same within ± 2%

    72. ESP100 OLR Circuit boards have conformal coating on them. Customer Benefit: Rugged design that will hold up in humid, corrosive environments

    73. ESP100 OLR No two labels are the same Every ESP100 overload is individually calibrated and a custom label is printed for that overload. Customer Benefit: Superior accuracy of dial setting - no competitor does this!

    74. ESP100 OLR Thermal Memory “Remembers” the heat buildup in hot or overloaded motors Customer Benefit: Trips faster on a restart since the motor windings are hot

    75. ESP100 OLR Simple Installation Mount it, wire it, dial in FLA Customer Benefit Fewer connections, saves installation time

    76. ESP100 OLR Retrofit Capabilities Direct Replacement for: Cutler Hammer Citation Line and Freedom Series GE 300 Line Square D Type S An additional “piggy-back” plate is available to retrofit the following: Allen Bradley Bulletin 509 and Bulletin 709 Westinghouse Series A200

    77. ESP100 OLR

    78. Starters with ESP100 Family

    79. Auxiliary Contact.

    80. Applications Machine tools Material Handling Compressors Hoists Automotives Industrial Equipment

    81. Starters Kits (for use with ESP100 only)

    82. Starters Kits – Customer Benefits Reduced lead-time – From Days to Minutes Reduce Inventory – Instead of stocking scores of different starters, simply stock a few starter kits, ESP100 kits and coil kits. With these basic “building blocks” you virtually have hundreds of products on-hand. Quality – Same high quality you are accustomed to with our products found in these new starter kits. UL Listed - By correctly following the instructions included with the kits, the product you build is UL Listed. Standard 110-120/220-240VAC dual voltage coil - Standard dual voltage coil, easily swapped with different voltage coil if required. Available in Non-Reversing sizes 00-4 and reversing sizes 0-2

    83. Product Lines Class 14 Non-Reversing starters From fractional HP up to 900 HP (NEMA size 00 – 8 including half-sizes) Operating voltages up to 575 V Overloads - ESP100 and Bimetal Ambient Compensated Class 22 Reversing starters From fractional HP up to 900 HP (NEMA size 00 – 8 including half-sizes) Operating voltages up to 575 V Overloads - ESP100 and Bimetal Ambient Compensated

    84. Product Lines Class 30 Two Speed One and Two Windings Constant or Variable Torque Constant Horsepower From fractional HP up to 100 HP (NEMA size 0 – 4 including half-sizes) Operating voltages up to 575 V Overloads - ESP100 and Bimetal Ambient Compensated Class 40 (Non-Reversing) & 43 (Reversing) Contactors From fractional HP up to 900 HP (NEMA size 00 – 8 including half-sizes) Operating voltages up to 575 V Vacuum contactors NEMA sizes 4,5 & 6 (Non-Reversing only)

    85. Nomenclature

    86. FLA 3Ø AC Motors

    87. Select Heater Select Heater for the following BiMetal Overload Relays Class 10 & 20. From the table in the catalog 14CP32A*81 SZ0, FLA 4.8, 460V 14GP32A*81 SZ2½, FLA 54, 230V 14DP12A*81 SZ1, FLA 20, 115V 3ø, 10HP, 460V, 60Hz, 3Pole 1ø, 2HP, 115V, 60Hz, 2Pole

    88. Heater Elements Catalog # CL10 CL20 14CP32A*81 K36 E46 14GP32A*81 K77 E78 14DP12A*81 K60 E61 14DP32A*81 K56 E57 14DP12A*81 K62 E65

    90. Lighting Contactor Product Lines

    91. Lighting Contactor Non-Combination

    92. Lighting Contactor Combination

    93. Lighting Contactor Features and Benefits Compact Design Enclosure Types: NEMA 1 Lift-Off Type “Clamshell” (Manufactured with TOX process) NEMA 1, 4x, 12 (field convertible to 3/3R) Hinged Standard Width and Extra Wide Enclosures Removable Door/Cover Up to 400Amps (20 – 60 available up to 12 poles, 100 – 400Amps 3 poles) Available in Combination form with choice of: Fusible Disconnect Non-Fusible Disconnect Circuit Breaker Pilot Device Mounting Holes in enclosures

    94. Lighting Contactor Non-Combination Starter - Features and Benefits Factory & Field Modifications Control Power Transformer (CPT) Pilot Devices Control Relays Control Fuses Auxiliary Contacts Terminal Blocks Control Modules Etc…

    95. Lighting Contactor Electrically Held Nomenclature

    96. Lighting Contactor Mechanically & Magnetically Held Nomenclature

    97. Lighting Contactor Field Modification Kits

    98. Lighting Contactor Field Modification Kits

    99. Lighting and Heating Contactors

    100. (CPTs)

More Related