1 / 10

Nano-10 based Building Automation System (BAS)

Nano-10 based Building Automation System (BAS). Jesús Baez March, 2011. BAS Architecture. Building Automation System (BAS) Features.

chika
Download Presentation

Nano-10 based Building Automation System (BAS)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Nano-10 based Building Automation System (BAS) Jesús Baez March, 2011

  2. BAS Architecture

  3. Building Automation System (BAS) Features • BAS allow to control the operation of up to 40 loads (on/off control,such as lighting, compressors, pumps, etc) using relay modules and 40 thermostat controlled air conditioning (AC) units. This control strategy results in important energy and billing savings. • Thermostat and relay modules are connected to Nano-10 via a RS-485 network (Modbus RTU protocol) • Setpoint definition for occupancy and non occupancy periods may be set independently for each thermostat using an easy to use Excel worksheet. This configuration may be done locally in each building or remotely via Intranet. • Occupancy and non occupancy periods are defined using an easy to use Excel interface. This configuration may be done locally, in each building or remotely via Intranet. • A Nano-10 is used in every building to monitor and control equipment status. • Using SCADA software running on a central server it is possible to collect and display real time and historical information (temperatures, energy consumption, equipment status)

  4. Thermostat and Relay configuration

  5. Operation hours(Occupancy/non occupancy period) definition using Excel Workbook Non Occupancy period Occupancy period

  6. Thermostat Setpoint definition (Occupancy /Non occupancy period)

  7. Thermostat Setpoint definition (Occupancy /Non occupancy period)using Excel Workbook Occupancy setpoint Non Occupancy Setpoint Lower and upper limit

  8. Nano-10 webpage showing equipment Status (“1” Enabled, “0” not enabled)

  9. Nano-10 webpage showing Thermostat configuration status

  10. Nano-10 webpage showing relay configuration status

More Related