An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High-End Field Server M. Hirafuji S. Ninomiya (National Agricultural Research Center) M. Wada (Panasonic) H. Shimamura (elab experience)

  2. Wi-Fi Mesh Network Field Server

  3. Long Range Communication

  4. Energy Consumption P P ∝ 1 / r2 r P/2 P/4 P/4 r/2 r/2

  5. Beam Antenna P/631 r Antenna Gain: 14dB Antenna Gain: 14dB

  6. 125mile (200km)

  7. “Urban Area” ProjectField Server Urban Sensor NetworkGarden City Field Server

  8. Cutting edge techs will be combined. Field Server FPAA Field Server Engine Neural Network Card and Camera Portable Spherical Display & Camera Pollen Counter Autonomous Robot

  9. Designing Garden City Field Servers

  10. Garden City Field Servers areFixed Point Robots? http://www.unipi.it/ateneo/comunica/comunicati1/ archivio/2005/maggio/20050518R2D2.htm_cvt.htm

  11. The Field Server obtained a servo motor to control a commercial digital camera.

  12. Natural Energy Quality and Quantities of Services Provided by Field Servers Correspond to Amount of Energy Consumption.

  13. Total Japan USA EU Others Total Japan EU Others USA World Photovoltaic Shipment http://www.sharp.co.jp/sunvista/about/result.html

  14. Global Warming + Heat Island

  15. Electricity Consumption of Computers Earth Simulator: 5MW Data Center

  16. GRID3: Sensor GRID, Data GRID and Energy GRID Sensor GRID“Field Server” Data GRID“MetBroker” Energy GRID“Field Storage Server”

  17. Information can be sent by Wi-Fi Merits of Field Servers depend on amount of energy consumption.

  18. Planting and Computing in Deserts 40~80 ℃

  19. Commercial Field Servers

  20. Hobbyists’ Activities Marine Field Server A Buoy with satellite link http://www.nirai-kanai.org/

  21. International Field Server Forum • Meeting • APAN • AFITA/WCCA • PRAGMA • Standardization • Related companies • Institutes, Universities • International Organizations