1 / 20

Thin Diamond Radiator Fabrication for the GlueX Experiment

Thin Diamond Radiator Fabrication for the GlueX Experiment. Brendan Pratt with Richard Jones University of Connecticut. NDNC 2014. Outline. Overview of GlueX UConn Laser Ablation Setup Analysis of Radiator Samples. NDNC 2014. 2. 2. The GlueX Experiment. NDNC 2014.

chuck
Download Presentation

Thin Diamond Radiator Fabrication for the GlueX Experiment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Thin Diamond Radiator Fabrication for the GlueX Experiment Brendan Pratt with Richard Jones University of Connecticut NDNC 2014

  2. Outline • Overview of GlueX • UConn Laser Ablation Setup • Analysis of Radiator Samples NDNC 2014 2 2

  3. The GlueX Experiment NDNC 2014

  4. Thin and Flat Diamonds • Radiators restricted to 20μm thickness due to multiple scattering • Must also have well defined crystal structure with whole crystal rocking curves less than 30μr • Techniques for thinning diamond exist, but they leave samples stressed and “potato chipped” • Laser ablation as a viable method for machining while keeping internal crystal structure unchanged NDNC 2014

  5. UConn Laser Ablation Facility • CNC style XY translation and laser pulsing via LabView • Ablation Chamber optimized to reduce amorphous carbon deposition on windows • Enhanced optics to reduce spherical aberrations (sub micron beam spot) Ablation Chamber Diamond L3 L2 L1 LASER X-Y-Z Translation Stage LabView NDNC 2014

  6. X-ray assessment: S150 surface of S150 was polished with RCMP process limited by instrumental resolution ! NDNC 2014

  7. X-ray assessment: S90 surface of S90 was not treated after VPIE process not as flat as S150, but still in spec. NDNC 2014

  8. X-ray assessment: S30 – the real target surface of S30 was not treated after VPIE process challenge lies here! NDNC 2014

  9. new idea tested in 2012: add a frame diamonds appear to warp severely when thinned to 20 microns try to stiffen the diamond by leaving a thick outer frame around the 20 micron region frame around 20 micron is still part of the single crystal, maintains planarity warping is from combination of mounting and internal stresses NDNC 2014

  10. First “picture frame” sample: U40 3 mm 315 micron frame around outside edge thinned inner rectangular window residual raster pattern is from a coarse laser step size NDNC 2014 10 10

  11. 3D Zygo Images of U40 White-light interferometer gives surface and thickness profiles with sub-micron prec. top surface measurements with Zygo approximate bottom surface depth, Zygo measurement on next slide NDNC 2014 11 11

  12. X-ray rocking curve for U40 surface of U40 was not treated after ablation excellent result for thinned diamond! NDNC 2014 12 12

  13. UC300-3-U25 • According to our measurements, this diamond was cut down 275µm. • Resulting in an active area that is less than 25µm thick NDNC 2014

  14. Thickness Profile NDNC 2014

  15. Surface Variation NDNC 2014

  16. Observations on ablated sample Central region looks good Sharpness of the walls does not degrade with depth Pileup of amorphous carbon is not catastrophic So far no clouding of the ablation chamber window from residue Excellent flatness of the central region Producing central regions <30µm Exploring annealing techniques NDNC 2014 16 16

  17. Questions? NDNC 2014

  18. Extra Slides NDNC 2014

  19. New vs. Old Spot Profile Wider spot size in y allows for larger step sizes and faster rasterizing. Aspect Ratio 1.5 Approx. 0.3mm Approx. 0.2mm Approx. 0.60mm after Approx. 0.15mm Aspect Ratio 4 before NDNC 2014 19 19

  20. NDNC 2014

More Related