120 likes | 364 Views
MHN-SB Pro 2000W Long Life. Introduction. For sports lighting applications, Life & Reliability is key. Most of the installations have a limited number of burning hours per year, though during these hours a very limited failure-rate is acceptable. Introduction.
E N D
Introduction • For sports lighting applications, Life & Reliability is key. Most of the installations have a limited number of burning hours per year, though during these hours a very limited failure-rate is acceptable
Introduction • A few lamp-manufacturers offer 2000W Short Arc lamps, though the majority has a very short lifetime, meaning very high Costs of Ownership : • - frequent high exchange costs • - frequent hassle / dark spots • and…… lack of confidence that the installation will perform properly during the match to come……
Introduction • Philips set a target to come up with a lamp: • Having the best lifetime and reliability as offered by benchmark competition, while….. • Having the same mechanical and electrical specifications as benchmark competition • From June 2004 onwards, this lamp is available and known as: • MHN-SB Pro 2000W 400V 956 Long Life
Specification • The naming ‘SB’, Short Base, clearly expresses the Shorter outer-dimensions of the new lamp compared to the well-known existing Master MHN-SA 2000W lamps Master MHN-SA 2000W; ‘double pinch’ technology’ MHN-SB Pro 2000W Long Life; ‘single pinch’ technology
Specification The naming ‘Long Life’, clearly expresses the lamp has been designed in such a way that the lifetime and reliability are at the highest possible standards with a Short Base design Life expectancy 100 MHN-SB Pro 2000W Long Life 90 Survivals in % 80 Osram HQI-TS 2000W D/S (OEM feedback & Philips laboratory tests) 70 60 50 1500 Burning hours 750 0
Competition Benchmark – Life Time Osram Specification Osram Reality Reliability Osram HQI-TS 2000W D/S: Extensive laboratory tests and OEM customer feedback learnt that Osram lamps have an average lifetime of less than 1000 hrs (!)
Competition Benchmark – Beam Control Philips MHN-SB Osram HQI-TS 25.8 mm 34.1 mm • Beam Control Philips - Osram: • The electrode distance of our MHN-SB Pro 2000W Long Life is 25.8 mm, as this distance is 34.1 mm for the Osram HQI-TS 2000W D/S • The shorter electrode distance of the Philips lamp allows OEM’s to save appr. 15% in the number of systems to be used to illuminate a stadium
Practical Advice • Luminaires need to be properly designed for the very high temperatures in these 2000 W systems. This is valid for all kind of 2000 W lamps available in the market • Luminaires which are not designed properly, will get polluted. This results in the need for regular cleaning of the entire luminaire. Polluted luminaires will result in shorter lamp-life
Market Introduction • Product Positioning High-End MASTER MHN-SA superior light quality & arc MASTER MHN-LA superior lifetime Mid MHN-SB Pro good light quality & arc good lifetime performance Low-End HPI-T 2kW HO good light output reliable life & maintenance HQI-TS 2000 W D/S operates at 'Pro' level
Annex: Lifetime Master MHN-SA/LA versus MHN-SB Pro Long Life Life expectancy 100 Survivals in % 90 Master MHN-LA 2000W 80 Master MHN-SA 2000W 70 60 MHN-SB Pro 2000W Long Life 50 0 1000 2000 4000 5000 Burning hours 3000 • MHN-SB Pro lifetime is ‘guaranteed’ till 1500 hrs, but will be extended in future (limited burning hrs in lab. so far) • Because of the ‘double pinch’ technology, Master MHN-SA/LA will always have a better lifetime-performance than the ‘single pinch’ MHN-SB Pro • The Master MHN-LA has been specially developed to have an extremely long life (12.000 hrs > 50% survivals)