S. Sgobba EN-MME-MM CERN

CERN + CNDA + ASIPP visit to RX Solutions, 15 April 2013. CERN, recent results on CC He-inlet inspection: excellent correspondence between optical inspections and indication by XR tomography. S. Sgobba EN-MME-MM CERN.

cira
Download Presentation

S. Sgobba EN-MME-MM CERN

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CERN + CNDA + ASIPP visit to RX Solutions, 15 April 2013 CERN, recent results on CC He-inlet inspection: excellent correspondence between optical inspections and indication by XR tomography S. Sgobba EN-MME-MM CERN

  2. Progress Meeting on CC, contract ITER/CT/09/4100001006 & CC PA - phases II and III 6 to 8 Nov. 2012 Analysis of 2nd prototype CC He inlet sample at CERN D. J. Marcinek, T. Ziemba, S. Sgobba EN-MME-MM CERN

  3. samples delivered to CERN Oct. 1st, 2012 first submitted to NDE (computed RT and XR tomography by RX Solutions/FR, phone discussion with N. Dolgetta, 5/10/2012)

  4. EasyTom Tomography_inlet_5 Tomography_inlet_7 examination performed by RX on the two He inlets delivered Oct. 1st, 2012

  5. Plan of cutting, mainly based on results of XR tomography Visual observations on internal surface of the welded nozzles after cutting

  6. Cross-sections of the He inlet samples N⁰ 5 (a) and N⁰ 7 (b): crack in the parent material of cable conduit next to the weld root of sample N⁰ 5 and tomographic view in perpendicular direction

  7. N⁰ 5 Face B Longitudinal section in sample N⁰ 5. The observed plane coincides with to the one of the tomographic view above. Porosity and cracks are straightforwardly confirmed. Detailed views of the defects visible in longitudinal cut of sample N⁰ 5: a) gas pore (ref: 2011); b) crack (ref: 100)

  8. N⁰ 7 Face A N⁰ 7 Face A Single shot of tomography performed on sample N⁰ 7 and longitudinal section in sample N⁰ 7 corresponding to the tomographic shot above. Defect visible in longitudinal cut of sample N⁰ 7: micro-crack (ref: 1001)

  9. Progress Meeting on CC PA at ASIPP CC PA 1.1.P3C.CN.01 Mar. 20, 2013 Metallurgical analysis of the 3rd prototype CC He inlet samples provided by ASIPP Dawid J. Marcinek, Mateusz Ziemba supervisor: Stefano Sgobba EN-MME-MM CERN EDMS nr°1272308

  10. Delivery and test description • ITER CC He Inlets samples delivered to CERN by ASIPP in Feb. 2012 • Two welded with buttering (B1 and B2) and two without buttering (WB1 and WB2) • One sample of each weld selected (following VT) for qualification (B1 and WB2) • Tomography based(RX Solutions /FR) selection of metallurgical cutspositions for cross-sectional destructive examinations • Classification following ISO 6520-1 and judged with respect to EN ISO 5817 - level B Marking corresponds to tomographic views: RV – rear view, SV – side view, FV – front view

  11. XR tomography results XR tomography was performed by RX Solutions /FR,allowing to access defects in the whole weld volume with higher resolution than through computed RT. Sample B1 Video progressing from RV to FV Sample WB2 Video progressing from RV to FV

  12. Micro-observations Metallographic investigations have been performed on carefully polished transversal cross-sections, selected on the basis of results of tomographic inspection. Due to the very fine size, the indicated cut (red line) followed by progressive polishing was not successful in visualizing these defects on cross-cuts. Gas cavity/porosity (ref: 201) acceptable to ISO 5817 level B Sample B1 FV Lack of fusion(ref: 401) unacceptable to ISO 5817 level B

  13. Micro-observations • Tomographic observations revealed tungsten inclusions Sample WB2 RV Tungsten inclusions (ref: 6021), according to ISO 5817 level B, acceptance depends on application Sample WB2 FV

  14. Micro-observations • Metallographic observations in transversal cross-cutin the position identified by XR tomography Lack of side wall fusion(ref: 4011) not permitted to ISO 5817 level B Sample WB2SV Excessive penetration (ref: 504) acceptable to ISO 5817 level B(h ≤ 1 mm + 0.1 b, where b is a width of weld reinforcement)

  15. Discussion and conclusion •  Based on findings of tomography, weld defects could generally be confirmed and assessed •  Internal defects identified by tomography were generally confirmed • Good applicability of the technique for qualification purposes • Technique much more exhaustive than computed radiography