1 / 19

NS1000 V3.0 - System Resource and Peripheral Incensement -

NS1000 V3.0 - System Resource and Peripheral Incensement -. Rev1.1 31 July, 2013. Table of Contents. 1. Overview 2. What is enhancement 3. How to program. Chapter 1 Overview. 1. Overview. Solution. Selectable System capacity (flexibility configuration) . * Features New for V3.

clarke
Download Presentation

NS1000 V3.0 - System Resource and Peripheral Incensement -

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NS1000 V3.0- System Resource and Peripheral Incensement - Rev1.1 31 July, 2013

  2. Table of Contents 1. Overview 2. What is enhancement 3. How to program

  3. Chapter 1 Overview

  4. 1. Overview Solution Selectable System capacity (flexibilityconfiguration) * Features New for V3 Features and Benefits >> 3 types of system capacity patterns When you want to increase NT-phone capacity or H.323 capacity, you can change the system capacity on customer demand. • NS1000 supports TDA100D via Stackingcard. TDA100D is added for Legacy Gateway of NS1000.

  5. 1. Overview NS1000 adds new 2 types of system capacity patterns. System capacity can be selectable based on customer demand. Type-1: Standard Type (same as version 1.x & 2.x) Same as current System resource. This type will be used for the user who satisfy current system configuration. Type-2: IP Extension Type Increase number of IP terminal and decrease number of SIP terminal This type may be used for the user who want to increase NT phone. Type-3: System Resource Type Increase Tenant and H323 expanding This type may be used for the user who want to increase more Tennant and/or Q-Sig node Note: This selection must be set when proceeding Easy Setup Wizard TDA100D Cabinet can be Legacy GW for NS1000. Add supported optional cards for Legacy GW.

  6. Chapter 2 What is enhancement

  7. 2-1Selectable System capacity SelectableExtension capacity When select Type2 mode, IP-PT extension capacity will be increased up to 640. In Type3 mode, SIP extension capacity will be changed.

  8. 2-1Selectable System capacity SelectableIP-GW Capacity When select Type3 mode, IP-GW (H323) capacity will be increased up to 96

  9. 2-1Selectable System capacity Selectable Tenant Group capacity When select Type3 mode Tenant Group capacity will be increased up to 128

  10. 2-1Selectable System capacity Increase COS and Carrier for each Unit Other resources will be increased COS 512, Carrier 128 per standalone unit

  11. 2-2 Add TDA100D as Legacy GW Legacy Gateway by KX-TDA100D Cabinet of KX-TDA100D can be used as Legacy Gateway to expand legacy trunks and phones. NS1000 can have stacking connection with TDA100D by changing MPR card to STACK-S card in TDA100D same as TDE series (KX-NS0132). RemoveMPR card Insert STACK-S card Stack-Scard S/W Version should be 2.000 or later TDA100D KX-TDA100D is allowed to be set with another KX-TDA100D on a NS1000 as Legacy Gateway. TDA100D add as additional GW category. - Category1: NCP500 /NCP1000 - Category2: TDE100/200, TDA100/200 - Category3: TDE600/620, TDA600/620 - Category4: TDA100D

  12. 2-2 Add TDA100D as Legacy GW Legacy Gateway by KX-TDA100D The maximum number of Legacy Trunk and Extension *1 : The maximum number with DXDP

  13. 2-3 Add Optional cards Optional cards for Legacy Gateway Following cards are supported for Legacy Gateways For TDE100/200, TDA100D For TDE600/620 For TDA100D

  14. Chapter 3 How to Program

  15. 3. Howe to Program System Initialize > Easy Setup Wizard It is necessary to select the type while proceeding Easy Setup Wizard, when you want to change System Capacity Type. System Capacity Type can’t be changed while system running unless initialize NS1000. Note: You can not select System Capacity Type when you upgrade software from Version 2 to Version 3 without Off-Line Tool.

  16. END

  17. Appendix

  18. Appendix System capacity When you select type 2 or type 3 system capacity, V-SIPEXT capacity is changed at each type. Default : <Type 1> 20 cards (640 ports) System Capacity Type 2 SIPEXT : 8 cards (256 ports) System Capacity Type 3 SIPEXT : 12 cards (384 ports)

  19. Modification 20130730-015 NS1000 V3.0 System Resource and Perifperal_Rev1.0_30Jul2013.pptx - 1strelease 20130731-01 Modified page 5 ‘overview’ and page 13 ‘Description for card’ . - Revision 1.1

More Related