Development of metal-loaded liquid scintillators for the double beta decay experiment

Development of metal-loaded liquid scintillators for the double beta decay experiment. 연세대 : 황명진 , 권영준 서울대 : 곽정원 , 김상열 , 김선기 , 김승천 , 김태연 , 명성숙 , 방형찬 , 이명재 , 이직 , 이현수 세종대 : 김영덕 , 이정일 경북대 : 김홍주 이화여대 : 박일흥 , 한인식 IHEP:J.Li 칭화대 : J.J.Zhu,D.He. ( A,Z+1). ( A,Z). ( A,Z+2).

Download Presentation

Development of metal-loaded liquid scintillators for the double beta decay experiment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Development of metal-loaded liquid scintillators for the double beta decay experiment 연세대:황명진,권영준 서울대:곽정원,김상열,김선기,김승천,김태연,명성숙, 방형찬,이명재,이직,이현수 세종대:김영덕,이정일 경북대:김홍주 이화여대:박일흥,한인식 IHEP:J.Li 칭화대:J.J.Zhu,D.He

  2. (A,Z+1) (A,Z) (A,Z+2) Double beta decay process (A,Z) -> (A,Z+2) + 2b + 2 n

  3. Why bb decay is important?

  4. 0n-DBDPresent best experimental limits * Staudt, Muto, Klapdor-Kleingrothaus Europh. Lett 13 (1990) 31 Experiment Isotope T1/20n (y) <mn>* (eV) Range <mn> 6.0 48Ca > 1.8 ´ 1022 Ogawa I. et al., submitted 2002 76Ge > 1.9 ´ 1025 0.35 < 0.3 - 2.5 Klapdor-Kleingrothaus et al. 2001 > 1.57 ´ 1025 0.38 < 0.3 - 2.5 Aalseth et al 2002 4.8 < 1.4 - 256 100Mo > 5.5 ´ 1022 Ejiri et al. 2001 1.9 < 1.8 - 6.2 116Cd > 1.3 ´ 1023 Zdenko et al. 2002 128Te > 7.7 ´ 1024 1.0 < 1.0 - 4.4 Bernatowicz et al. 1993 130Te > 2.1 ´ 1023 1.5 < 0.9 - 2.1 Mi DBD n 2002 136Xe > 7 ´ 1023 1.8 < 1.4 - 4.1 Belli et al. submitted PLB

  5. Why metal loaded liquid scintillator? • Advantage • a) high-Z can be loaded to LS (>50% or more) • b) Fast timing response (few ns) • c) Low cost of LS, Large volume is possible • d) U/Th/K background for LS is low and purification • is known • Disadvantage • a) Bigger volume is necessary (C,H in LS, low density) • b) Lowerlight output (~15% of NaI(Tl))

  6. Tin loading study • Tin compound 1) Tetramethyl-tin (40%w50%) : flammable,expensive 2) Tetrabutyl-tin (19%w50%) • LS : Solvent+Solute * Solvent ; PC 1L * Solute ; POP 4g * Second-solute ; POPOP 15mg * Others ; Nd2-ethylhexanoate, Zr2-ethylhexanoate.

  7. LSC test sample HV + LSC Setup VME

  8. Passive shielding at Y2L(700m depth) PE shield (5cm) Pb shield (15cm) Mineral Oil shield (30cm)

  9. Double beta decay detector Quartz glass Plastic Dimension R = 5cm H = 15.2cm V = 1.18L Teflon

  10. e- h e- SourceºDetector (calorimetric technique) +high energy resolution -no event topology Simulated spectra of 2b decay experiment with 100Mo (Q=3034keV) Modern Physics,Volume74, 2002

  11. b – a coincidence candidates 238U chain • 214Bi : 3.27 MeV b-decay • g 214Po : 7.833 MeV a -decay • Lifetime of 214Po = 0.1643 ms • 100 keV Energy threshold

  12. 214Bib-decay g214Poa-decay s -> T 1/2 = 0.166ms

  13. 214Bib-spectrum 214Poa-spectrum Q=3.27MeV Q=7.833MeV Ee(keV) Ee(keV) 214Po - a decay - Quanching factor = 9.1% - 67개/day

  14. TMSN50% Energy Spectrum by CAMAC pol3 + gaus fitting Ee(keV) Ee(keV)

  15. TMSN50% Energy Spectrum by 500MHz FADC pol3 + gaus fitting Ee(keV) Ee(keV)

  16. Sensitivity T 1/2 = log 2 ´e ´ N ´ T / dS e : efficiency N : Number of double beta nuclei T : Data taken time with year dS : mean value + 1.64s of Gaussian fitted area (mean value is Q-value)

  17. Summary 1. TMSN50% by CAMAC -> 123 days T1/2 = 5.56x1019 year by 90% C.L 2. TMSN50% by 500MHz FADC -> 33 days T1/2 = 3.41x1019 year by 90% C.L 3. World limit = 2~5x1017 year by 1952

  18. Plan • Nd2EH and Zr2EH study • Background reduction • 2n DB study • Background understanding • More exact Calibration • U238, Th 232 decay chains study