1 / 56

50 MHz “Aviso” Linear probe in anterior segment ultrasound

50 MHz “Aviso” Linear probe in anterior segment ultrasound. Dr P.A.Good Birmingham U.K. Frequency and depth. THE NEW & UNIQUE PROBE 50 MHz LIN. 50 MHz : QM transducer Linear : better perpendicularity Wide scan : to visualize the whole AC. SECTOR FOR RETINA. SECTOR FOR AC.

clive
Download Presentation

50 MHz “Aviso” Linear probe in anterior segment ultrasound

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 50 MHz “Aviso” Linear probe in anterior segment ultrasound Dr P.A.Good Birmingham U.K.

  2. Frequency and depth

  3. THE NEW & UNIQUE PROBE50 MHz LIN • 50 MHz : QM transducer • Linear : better perpendicularity • Wide scan : to visualize the whole AC

  4. SECTOR FOR RETINA SECTOR FOR AC SECTOR PROBES

  5. ARC LINEAR NEW PROBE TECHNOLOGY

  6. Short focal length probe (20 MHz) • Whole of anterior segment can be seen. • No need for waterbath. • Adjustment of probe position maintains different focal plane over 10 mm. • Displaced IOL implant • Note in the right eye the lens is too anterior, resulting in iris bowing and refractive error

  7. UBM ULTRASOUND BIOMICROSCOPY C.J. PAVLIN (50 MHz)

  8. High Frequency Ultrasound Imaging • Anterior Segment Imaging : 50MHz =>1991:UBM :Sector scan => Glaucoma C Pavlin => 1994 : ARTEMIS: Arc Scan => Refract. Surg D Reinstein, R Silverman, J Coleman => 2005 : AVISO: Linear Scan Quantel Medical • Posterior Segment Imaging : 50 MHz =>1999:US Patent PCT FR 98/02788 (Michel Puech ) => 1999: IOVS : 5O MHZ Ultrasound Imaging of Macula Michel Puech

  9. Artemis ( Ultralink)50 MHz ArcScan

  10. Visante-OCT ( Carl Zeiss):G Baikoff Visante OCT : poor resolution on Cornea Limited penetration for Ciliary body

  11. Pentacam: Scheimpflug Camera Pentacam: Poor visualisation of Angle

  12. AVISO (Quantel Medical) 50 MHz Linear

  13. 50 MHz LINPROBE Peter GOOD – Birmingham & Midland Eye Centre AC trauma

  14. AVISO: 50 MHz Linear

  15. Corneal Scar

  16. Corneal dermoid

  17. Acanthoemeba

  18. Keratoconus

  19. Keratoconus

  20. Keratoconus

  21. Corneal melt

  22. Corneal melt

  23. Corneal melt/Uveitis

  24. Corneal melt/Uveitis

  25. Corneal foreign body

  26. Plateau Iris AVISO (Quantel Medical): 50 MHz Linear Light Dark

  27. Plateau Iris UBM 50 MHz Linear OCT 3

  28. Plateau iris

  29. Synechiae

  30. Molteno tube

  31. Molteno tube

  32. Dialysis

  33. Silicone Oil

  34. Malignant Melanoma of Ciliary Body UBM ( 50 MHz ) AVISO : 50 MHz Linear

  35. Ciliary body MM

  36. Iris melanoma

  37. Nd YAG Iridotomy AVISO (Quantel Medical) : 50MHz Linear

  38. Ciliary Body UBM (50MHz) 50 MHz Linear

  39. 50 MHz Aviso UBM/linear probe Phacomorphic Glaucoma

  40. Phacomorphic Glaucoma

  41. Phacomorphic Glaucoma

  42. Phacomorphic Glaucoma

  43. Nanophthalmos

  44. UBM/Linear probe of iris cyst

  45. Iris cyst

  46. UBM/Linear probe/ciliary processes and cyst

  47. AC cyst

  48. UBM/Linear probe/bleb:scleral cleft

  49. Scleral Cleft

  50. UBM/Linear probe:Anterior scleritis

More Related