1 / 2

does tylosin expire

Tylosin Residue Rapid Test Strip (Milk) can be provided from Creative Diagnostics.<br>https://www.creative-diagnostics.com/Tylosin-Residue-Rapid-Test-133225-452.htm<br>

creatived11
Download Presentation

does tylosin expire

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Tylosin Residue Rapid Test Strip (Milk) Tylosin Residue Rapid Test Strip (Milk) Cat. No.:DTS992 Pkg.Size: Intended use The Tylosin Rapid Test is a competitive immunoassay for the semi-quantitative detection of the presence of Tylosin residue in milk. General Description Tylosin (MW = 916.14), is a macrolide antibiotic that is active against gram-positive and gram-negative bacteria. It is also effective in treating respiratory diseases caused by mycoplasms. It is widely used as a feed additive for growth promotion as well as therapeutically in food producing animals, including cattle, chickens and swine. Tylosin is also used for the reduction of the incidence of liver abscesses caused by sphaerophorous necrophorous. Food and Drug Administration of the United States has set the guidelines for the allowable level of tylosin in animal feeds and the specific tolerance for tylosin in edible products of animals. Tylosin EIA kit is a rapid and simple detection system for tylosin in feed extract. Principle Of The Test The Tylosin Rapid Test is based on competitive lateral flow immunochromatographic assay. The Tylosin conjugate in the test zone will capture the immuno-gold (colloid gold- Tylosin antibody conjugate), when there is very little dissociative Tylosin in the samples. A visible red test band indicates a negative result when the control line (C zone) shows that the card is valid. The test band (T zone) will be not visible if Tylosin is present in concentration of 50 ppb and above which explains a positive result. Reagents And Materials Provided 1. 10×foil pouches each contain one cassette, one pipette and a desiccant 2. 10×centrifugal tubes (1.5 mL) 3. Product Manual Storage The kit can be stored at room temperature (2-30°C). The test kit is stable through the expiration date (18 months) marked on the foil pouch. DO NOT FREEZE. Do not store the test kit in direct sunlight. Interpretation of Results Positive: Only one clear band in C zone indicates a positive result. Positive shows that the concentration of Tylosin is at or above 50 ppb in the samples. Negative: The presence of both clear band in C zone and T zone. Invalid: No colored band appears in C zone. Creative Diagnostics. All rights reserved 45-16 Ramsey Road Shirley, NY 11967, USA Tel: 631-624-4882 ·Fax:631-614-7828 E-mail: info@creative-diagnostics.com www.creative-diagnostics.com 1

  2. Specificity The results are negative when the test card is applied to detect 100 ppm of Chloramphenicol, Aminoglycosides, Erythromycin, Tetracycline and Beta-lactam. Limit of Detection Cut-off: 50 ppb Precautions 1. For best results, please strictly adhere to these instructions. 2. All reagents must be at room temperature before running the assay. 3. Do not remove test cassette from its pouch until immediately before use. 4. Do not reuse the test kit. 5. Do not use the test beyond its expiration date marked on the foil pouch. 6. The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers. Limitations The Tylosin Rapid Test is an useful tool offering a rapid and accurate testing in field screening, exceeding with its convenience. It provides a semi-quantitative method to detect the Tylosin above 50 ppb in milk. If you want a quantitative result, it is suggested to apply other method such as ELISA / HPLC in practice. Creative Diagnostics. All rights reserved 45-16 Ramsey Road Shirley, NY 11967, USA Tel: 631-624-4882 ·Fax:631-614-7828 E-mail: info@creative-diagnostics.com www.creative-diagnostics.com 2

More Related