1 / 10

Halftoning for High-Contrast Imaging

New Technologies for Probing the Diversity of Brown Dwarfs and Exoplanets – Shanghai 2009. Halftoning for High-Contrast Imaging. P. Martinez 1 C. Dorrer 2 , E. Aller Carpentier 1 , M. Kasper 1 , A. Boccaletti 3 , and K. Dohlen 4 1 European Southern Observatory 2 Aktiwave – Rochester N.Y

cwen
Download Presentation

Halftoning for High-Contrast Imaging

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. New Technologies for Probing the Diversity of Brown Dwarfs and Exoplanets – Shanghai 2009 Halftoning for High-Contrast Imaging P. Martinez1 C. Dorrer2, E. Aller Carpentier1, M. Kasper1, A. Boccaletti3, and K. Dohlen4 1European Southern Observatory 2Aktiwave – Rochester N.Y 3LESIA – Paris Observatory 4LAM – Marseille Observatory This activity is supported by the European Community under its Framework Programme 6, ELT design study.

  2. Halftoning principle & key parameters • Components are based on metallic micro-dots to generate spatially-varying transmission • displaying continuous-tonefilters with only black (opaque) and white (transparent) dots Free-space propagation Image from Dorrer et al. 2007, JOSA dot => 0% transmission (substrate + opaque metal) no dot => 100% transmission (substrate only) •  Key parameters (application-dependent) • shapeof the dots (square, hexagone…) • size of the dots [p], i.e. sampling problem (p >) • metal layer (Cr, Al…) • opticaldensity, i.e. opacity of the dots, OD() • algorithm used for dots distribution Impact the power spectrum of a microdot filter

  3. Halftoning for coronagraphy Apodized Pupil Lyot Coronagraph, APLC (Soummer et al., A&A 2003) (Idem for conventional pupil apodization coronagraph or Dual Zone coronagraph) Band-Limited coronagraph, BL (Kuchner et Traub, ApJ 2002) (see talk of M. Kuchner this afternoon)

  4. Diffraction stray-light: APLC pupil apodizer • The smaller the dots are, the better the transmission profile matches the desired one • (i.e. sampling problem, S =pupil diameter / dot size) • The APLC coronagraphic image is affected by: • Deterministic effect: diffraction peaks (dot scatters light) • Stochastic effect: speckles will border diffraction peaks (dots distribution is not regular) •  theoretical derivations in Martinez et al. 2009a, A&A 495 Laboratory validation (Martinez et al. 2009b, A&A 500) 15 microns 30 microns 60 microns 120 microns 240 microns Dot size (μm) S = 200 S = 100 S = 50 S = 25 S = 12.5 Pupil plane (3mm) prototypes APLC coronagraphic images 1.2”

  5. Diffraction stray-light: BL focal plane mask Ψpupil plane = [ FT( Mask BL) ✪ pupil ] ✖ pupil-stop Ideal mask Microdot mask Numerical noise Metric: s = (F#xλmin) / pFurther details in Martinez et al. 2009c, ApJ submitted Contrast 10-8 (IWA) to 10-10 Ok if IWA > 3 λ/D

  6. Final prototype: APLC pupil apodizer Filter shape: Prolate-like function Diameter pattern: 3 mm Metal layer: Cr OD 4(standard) Dot size: 4.5 microns S = 660 Local profile accuracy: 3% (new proto => 2%) Achromaticity transmission 1% (J and H-band)

  7. Final prototype: BL focal plane mask Filter shape: 1 - sinc Diameter pattern: 10 mm Material layer: Al OD 8+ in near-IR Dot size: 5 microns s = 16 Local profile accuracy: ~ 5% (new proto => 3%)

  8. Δλ/λ = 1.4% APLC & BL laboratory tests Δλ/λ = 24% APLC laboratory tests Band-Limited laboratory tests H-band Δλ/λ = 24% Laboratory experiment demonstrate correct behavior of the coronagraphs

  9. XAO APLClaboratory test on HOT PSF APLC High-Pass Filtered APLC • The High-Order Testbench (HOT) • AO bench developed at ESO • (Aller Carpentier et al., 2008 SPIE) • Seeing: 0.5” • DM: 31 x 31 actuators • AO cut-off frequency: 15 λ/D (0.6”) • APLC Contrast 5σ (HPF): • 2.5 10-4 @ 0.1” • 2.2 10-5 @ 0.5” • see poster: XAO coronagraphy with HOT

  10. Conclusion • It works: APLC and BLs using halftoning demonstrate correct behavior • Laboratory limitations originate from external error sources • Accurate • Achromatic • Reproducible • Cheep : 2-3k€ • Validated for the APLC on the SPHERE (VLT) & GPI (Gemini) instruments • Baseline for EPICS (E-ELT) • Not only for coronagraphy • (e.g. Laser beam shaping: Dorrer et al. 2007, JOSA – B, vol. 24)

More Related