1 / 23

The YL9100 S HPLC

The YL9100 S HPLC. All your needs for semi-preparative applications. YL9100S HPLC Overview. Superior Performance Greater Reliability Excellent Usability Serviceability and Easy Maintenance. Superior Performance. YL9100S HPLC – Features 1. Higher performance solvent delivery pump

Download Presentation

The YL9100 S HPLC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The YL9100S HPLC All your needs for semi-preparative applications

  2. YL9100S HPLC Overview • Superior Performance • Greater Reliability • Excellent Usability • Serviceability and Easy Maintenance

  3. Superior Performance YL9100S HPLC – Features 1 • Higher performance solvent delivery pump - New designed carrier assembly and CAM - Improvement of precision • Better UV/Vis detector with new optic design - For better light intensity and higher sensitivity • New Detector – Photo Diode Array with excellent sensitivity Semi-prep flow cell is available

  4. Greater Reliability YL9100S HPLC – Features 2 • Improvement of System components - New designed main parts of Pump, Detectors and Column compartment with very robust materials • Innovative manufacturing process - Three step quality control and assurance system

  5. Excellent Usability YL9100S HPLC – Features 3 • Intuitive, intelligent and powerful software - Easy control window for instruments of YL9100S HPLC - Harmonization Microsoft’s standards for accessing flies, reviewing data and reports, and other tasks - System Suitability Test with USP, EP and JP - Compliance with 21 CFR Part 11 - Diagnostics and Error detection • Automation Perfectly of Analysis work - Startup, analysis operation, shut down, … , and to report generation

  6. Serviceability and Easy Maintenance YL9100S HPLC – Features 4 • Better long-life components - New designed the carrier, CAM, needle bearing, seals and belt (with polyurethane) for long-life time - New designed the Deuterium and Tungsten lamp guaranteed 2,000 hours - Semi-permanent peltier in the Column Compartment • Easy Maintenance • - Easy replacement and pre-alignment of lamps • - Easy replacement of sample cell assembly • - Diagnostics procedure by software

  7. YL9100S HPLC – Modules List of Modules • Degassing Module • Pump • Column Compartment • UV/Vis Detector • PDA Detector • Refractive Index Detector • Prep Autosampler • Fraction Collector • Chromatography Data System

  8. YL9100S HPLC – Modules -HDVM • YL9101S Vacuum Degasser - No fluctuation, shorten warming up • Number of channel : 2 CHs (option: 4 CHs) • Maximum degassing range: 50ml/min • High capacity of chamber: 62ml per channel • Safety & maintenance : Vacuum Error detection • Wide range of Line Voltage : 100-240VAC, ±10%, Wide range • Line frequency : 50/60Hz, ±5% • Power consumption : 50W YL9101S Vacuum Degasser will be available by June

  9. YL9100S HPLC – Modules -HDVM • Helium Degassing Valve Module • Number of channel : 4 CHs • Degassing type: Helium gas (This module is required a He gas cylinder) • Wide range of Line Voltage : 100-240VAC • Line frequency : 50/60Hz

  10. YL9100S HPLC – Modules -VD • Vacuum Degasser – Stand-alone type • Number of channel : 2 CHs • Maximum degassing range: 50ml/min • Wide range of Line Voltage : 100-240VAC • Line frequency : 50/60Hz • Power consumption : 46W

  11. YL9100S HPLC – Modules – Pump • YL9110S Quaternary Pump • YL9111S Binary Pump • YL9112S Isocratic Pump • New design of mechanical parts of pumps • Compressibility Compensation technology • Semi-automatic Prime/Purge • Built-in Leak sensor • Wide flow range by each check valve with two balls • Ultra robust carrier, bearing, belt, etc • For isolation and purification of preparative HPLC • Flow rate: max. 50ml/min

  12. YL9100S HPLC – Modules – BP • YL9111S Binary Pump (Recommended for Semi-prep) • A New Pump for higher throughput and reproducibility • The best pump for High Pressure Gradient System • Built-in Large capacity static mixer • X2 Parallel dual-plunger • Attractive price compared to QP • Ideal pump for semi-prep application

  13. YL9100S HPLC – Modules – QP/IP • YL9110S Quaternary Pump • Attached 4-way mixing valve to QP • YL9112S Isocratic Pump • Improved Isocratic Pump with parallel dual-plunger • Easy upgraded from IP to QP

  14. YL9100S HPLC – Modules -CC • YL9130S Column Compartment - Powerful temperature control • The best temperature precision: ±0.05°C • Powerful Cooling is the standard: down to 4 °C • Preheating available • Semi-automatic injector/Switching valve: up to 1(option) • Column capacity: 300mm – 2ea • Leak sensor • 40 steps programming • Column OD: up to 28mm

  15. YL9100S HPLC – Modules -UVD • YL9120S UV/Vis Detector - Excellent sensitivity • New designed Optic structure: Seya-Namioka • New Blazed Holographic Concave Grating • Excellent Data acquisition rate: up to 50 Hz • Long-life D2 lamp, 2000 hours guarantee • Advanced band width: 5.5 nm • Excellent Sensitivity: <±0.5 x 10-5 AU at 254nm • Integrated cell and slit assembly • Greater cooling of the lamp’s thermal environment • Optimal cell volume and path length for semi-preparative purpose • Leak sensor

  16. YL9100S HPLC – Modules -UVD • YL9120S UV/Vis Detector • What is the Seya-Namioka monochromator - To attach New Blazed Holographic Concave Grating - Extremely low stray light - Highest light intensity - Reduced astigmatism - Very compact design and size - More serviceability - High performance beam splitter - New designed an integrated cell+slit assembly - Excellent band width, 5.5nm

  17. YL9100S HPLC – Modules -PDA • YL9160S PDA Detector - Highest Sensitivity • Optimum wavelength resolution: 1,024 diodes • Wide range from 190 to 950 nm • Highest Sensitivity <±1.0 x 10-5 AU at 254nm, 2 sec rise time <±2.0 x 10-5 AU at 254nm, 1 sec rise time • Fast data acquisition: 50 Hz • Greatest drift level <2.0 x 10-4 AU/h at 254nm, Baseline correction <1.0 x 10-3 AU/h at 254nm

  18. YL9100S HPLC – Modules -RID • YL9170S RID - For universal detection • RI Range : 1.00 ~ 1.75 RIU • Noise : < ±1.0 x 10-7 RIU • Linear dynamic range : 0-20000 μRIU • Flow rate range : 1 ~ 50.0 ml/min • Cell pressure : 6 kg/cm2(84 psi)

  19. YL9100S HPLC – Modules -AS • YL9150 Autosampler – Prep Autosampler - Fully automated work • Sample capacity: 24 vials(10ml for prep) • Sample loop: 10ml • Injection: partial loop • RSD ≤ 1.0% for partial loopfill. • Carry-over < 0.1% • Option: Built-in Peltier cooling (4oC ~ ambient –3oC)

  20. YL9100S HPLC – Modules -FC • Fraction Collector – FC204/203B A stand-alone operation using time, drop or peak based collection • Collect fractions by time, drop or peak with ease; manual collection is also available • Simply set the time or number of drops, press START and walk away • Drop counting: Up to 9,999 drops per fraction Maximum rate: 20 drops/sec • HELP, YES, NO, 0-9 numeric hard keys/four soft keys • 2-line, 24-character display on backlit LCD

  21. 2 Post-run Automatically displays, prints, exports and starts other programs YL9100S HPLC – Modules -CDS • YL-Clarity CDS - Intelligent and Powerful Chromatography Data Station 1 Measuring Four Instruments up to 12 detectors.

  22. 6 7 3 4 5 8 User accounts Sets up access rights and passwords Networked Solution Clarity files can be accessed from networked computers using Clarity Offline software. Audit trail Records selected events and operations into a special file. Column performance Method validation By USP, EP and JP Electronic signature Each chromatogram can be signed electronically. Great Compatibility Window XP/2000. Window Me/98, and Window Vista (32bit) is available YL9100S HPLC – Modules -CDS

  23. YL9100S HPLC – Modules -CDS • YL-Clarity CDS • Perfectly compliance with 21CFR Part 11 • GPC option available • System Suitability Test option available(Method validation) • PDA module option available: 3-D data analysis • Software Validation option available: Software OQ S/W validation kit

More Related