1 / 13

Instrumental Neutron Activation Analysis (INAA)

Instrumental Neutron Activation Analysis (INAA). F rank L aboratory of N eutron P hysics Summer school in Dubna 5.7.-25.7.2010 Prepared by: B. Andel (SVK) , E. Govor (BLR), K. V. Mareš (CZE), M. Mazánová (SVK), A. Moravcsík (SVK), V. Voronova (BLR) Supervisor :

damara
Download Presentation

Instrumental Neutron Activation Analysis (INAA)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. InstrumentalNeutronActivationAnalysis (INAA) Frank Laboratory of Neutron Physics Summer school in Dubna 5.7.-25.7.2010 Prepared by: B. Andel (SVK), E. Govor (BLR), K. V. Mareš (CZE), M. Mazánová (SVK), A. Moravcsík (SVK), V. Voronova (BLR) Supervisor : prof. M. V. Frontasyeva, FLNP

  2. The founders of FLNP

  3. Introduction • Neutron Activation Analysis (NAA) is a sensitive multi-element analytical technique used for both qualitative and quantitative analysis of major, minor, trace and rare elements • NAA was discovered in 1936 by G. Hevesy (Hungary) and H. Levi (Denmark)

  4. Forms of NAA • Destructive ( radiochemical ) -theresulting radioactive sample ischemicallydecomposed, and the elementsare chemically separated • Nondestructive(instrumental ) -the resulting radioactive sample iskept intact

  5. Principle

  6. Detection • Irradiated samples are analyzed by gamma-spectrometry

  7. Neutron sources • Isotopic neutron sources (252Cf, 242Am) • Neutron generators • Nuclear reactors • At FLNP the pulsed fast reactor IBR-2 is used

  8. Neutrons • Thermal 0.025 eV-0.5 eV • Epithermal 0.5 eV-100 keV • Fast 100 keV-25 MeV

  9. Characteristics of INAA • Non-destructive analysis • The chemical formand physical state of theelements donot influence the activation anddecayprocess • Multi-element analytical technique • C, H, N, O and Sido not activate well • Suitable even for determination of masses in the order of 10–6–10–9 g and less

  10. Applications of INAA at FLNP • Environmental studies (migration of pollutants in ecosystems, air pollution studies using moss-biomonitors) • Biotechnology for medicine (development of new pharmaceuticals and sorbents) • Material Science (high purity materials, nanoparticles and objects of national heritage)

  11. Dependence of counts on distance between detector and gamma-source

  12. References • P. Bode: Instrumental and organizational aspects of a neutron activation analysis laboratoty • http://www.sciner.com/Neutron/naa.html • http://reactor.engr.wisc.edu/naa/ • http://tin.er.usgs.gov/geochem/doc/inaa.htm • http://reactor.engr.wisc.edu/naa/UWNRNAA.htm • http://www.reak.bme.hu/Wigner_Course/WignerManuals/Budapest/NEUTRON_ACTIVATION_ANALYSIS.htm • http://archaeometry.missouri.edu/naa_overview.html

  13. Foto by Kamil Vavrinec Mares Thank you for your attention

More Related