1 / 43

ACCELERATOR DESIGN OF THE NSLS-II SYNCHROTRON LIGHT SOURCE

ACCELERATOR DESIGN OF THE NSLS-II SYNCHROTRON LIGHT SOURCE. W. T. Weng CENTER OF ACCELERATOR PHYSICS, BNL Forum on Low Emittance Intermediate Energy Synchrotron Light Source

damian
Download Presentation

ACCELERATOR DESIGN OF THE NSLS-II SYNCHROTRON LIGHT SOURCE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ACCELERATOR DESIGN OF THE NSLS-II SYNCHROTRON LIGHT SOURCE W. T. Weng CENTER OF ACCELERATOR PHYSICS, BNL Forum on Low Emittance Intermediate Energy Synchrotron Light Source August 19-20, 2004 NSRRC, Shin-Chu, Taiwan

  2. ACKNOWLEDGMENT The material presented here are provided by scientists at NSLS, especially Drs. S. Dierker C. C. Kao J. Murphy S. Kramer Zhong Zhong

  3. Present NSLS X-Ray Ring 2.8 GeV 275 mA 80 Operational Beamlines VUV/IR Ring 800 MeV 1000 mA

  4. Diverse Science:Users by Field of Research Largest groups are materials and life sciences Strongest growth in life sciences

  5. National & Regional Resource 2400 Users/year(> 400 academic, industrial, government institutions) New York (32%) Central to BNL programs (16%) International Other Northeast States (27%) (25%) Non-Northeast States Industry: IBM, ExxonMobil, Lucent, pharmaceuticals

  6. NSLS -- I • First Dedicated Second Generation Synchrotron and only remaining second generation DOE synchrotron! • Designed in the 1970’s • Operating Since 1982 • Continually updated over the years - Brightness has improved more than 100,000 fold • However, we are at the theoretical limit with existing ring • Restricted capabilities of present NSLS are increasingly limiting the productivity and impact of its large user community • Major improvements require replacing ring

  7. 10+ Year Vision: Enable Grand Challenge Science by Providing World Leading Capabilities What science will users do in 10+ years, and what do they need ? • Soft Matter & Biomaterials Workshop – April ‘02 • 8 Workshops at NSLS Users Meeting – May ‘02 • Ultra-high Resolution X-ray Spectroscopy Workshop – September ‘02 • Low Energy Electrodynamics in Solids Conference – October ‘02 • Microbeam Diffraction Workshop – January ‘03 • 6 Workshops at NSLS Users Meeting– May ‘03 • Scientific Opportunities in Macromolecular Crystallography at NSLS-II – July ‘ 03 • NSLS-II Environmental Science – August ‘03 • Strongly Correlated Electrons: NSLS-II and the Future – August ‘03 • Scientific Opportunities in Soft Matter and Biophysics at NSLS-II – Sept. ‘03 • Biomedical Imaging at NSLS-II– September ‘ 03 • Nanoscience and NSLS-II– October ‘03 • Workshop for NSLS-II– March ‘04 • CD0 Review Feedback, August ‘04

  8. MAJOR DESIGN CONSIDERATIONS • Science Case and User’s Needs, National & International Competition, ( to be covered by C. C. Kao ) • Facility Type: FEL, ERL, SR, SR-ERL • Injector: Linac vs Booster, Top-Up • Lattice: Energy, Emittance, DBA vs TBA, SS • RF: Warm vs Cold, Frequency, Bunch Length, Voltage • Insertion: Superconducting vs PM Undulator, Photon E • Upgrade Path and Growth Potential • R&D Program, Critical Technology • Cost and Construction Schedule

  9. NSLS-II:Ultra-high Brightness Medium EnergyThird Generation X-Ray Ring and IR Ring X-ray Ring • 3 GeV, 500 mA, Top-off Injection • 24 Cell, Triple Bend Achromat • Circumference 620 m • 21 Insertion Device Straight Sections (7 m) • 24 Bending Magnet Ports • Ultra-Low Emittance (ex, ey) 1.5, 0.008 nm (Diffraction limited in vertical at 10 keV) • Brightness ~ 1021 p/s/0.1%bw/mm2/mrad2 • Flux ~ 1016 p/s/0.1%bw • Beam Size (sx, sy) 84.6, 4.3 mm • Beam Divergence (sx’, sy’) 18.2, 1.8 mrad • Pulse Length (rms) 11 psec • Exceptional intensity and position stability • Upgradeable to ERL operation in future Infrared Ring • 800 MeV, 1000 mA, Top-off Injection Highly Optimized X-ray Storage Ring Dedicated Enhanced Infrared Ring

  10. Parameters Of Some IE/LE Synchrotron Light Sources

  11. Summary of Proposed NSLS-II Lattices

  12. Lattice Design for NSLS-II • Design Goals and Lattice requirements • Choice of Linear Lattice and beam parameters design TBA vs DBA • Dynamic aperture and sextupole tuning • Longitudinal parameters and RF requirements • Impact of undulators on beam parameters • Conclusions and future research plans

  13. WAYS TO LOW EMITTANCE • Small bending, hence long circumference • TBA is better than DBA Cell • Combined function to reduce theta and increase DA • Non-zero dispersion in SS • Proper corrections to increase dynamical aperture • Additional corrections needed for for ID’s

  14. Design Goals and Lattice Design

  15. Lattice Design Process User Requirements Short & Long Term Stability Tolerance Errors Lattice Options TBA DBA Longitudinal Dynamics Impact Undulators Linear Lattice Design Non-Linear Distortions Dynamic Aperture tracking

  16. Choice of Linear Lattice Lattice Emittance related to bend angle in dipoles as

  17. Initial Lattice Choice TBA(24) S1 S2 SE SF SD 5 Sextupole Families- 3 Chrom, 2-Harm C=523m, ChromX= -100, Emitt.= 1.5nm

  18. Dynamic Aperture and Sextupole Tuning 5 Sextupole families 3-chromatic and 2- harmonic

  19. Optimize 2nd order Tune Shifts

  20. Dynamic Aperture from tracking DA > ( 11 x 11mm) Nsigma>( 544 x 7700) Real aperture adequate for injection without breaking periodicity FFT of tracked particles yields real tune shift with amplitude Shows higher order tune shifts dominate > 4-5 mm (4.4um)

  21. Pi-Transformer 2nd Order Cancellation 2nd order geometric terms cancel if identical sextupoles are separated by I.E. Pi - transformer TBA lattice tunes are Qx=1.56 /cell and Qy=0.56/cell this should give partial cancellation. +2 sextupole= 7 sextupole families

  22. Multi-cell Cancellation not Helping 7 families of sextupoles tuned Shows better cancellation But real tune shifts still big And quadratic in Ax and Ay DA not improved

  23. New Direction: Lattice Choice Revisited New user requirement longer undulators and injection straight 7m Quad to Quad length with space for bump in triplet Reconsider lattice choice for TBA

  24. Reconsider DBA(28) 2QF QD QD QF QD High Vertically Focusing Gradient Dipoles Jx =1.45 Zero Gradient Dipoles

  25. DBA(28) Lattice with 7m ID’s Enhanced DBA lattice with high gradient dipoles developed with circumference C= 630m, mostly due to ID length EDBA(28) Achromatic lattice EDBA(28) non-Achromatic lattice

  26. Sextupole Tuning yields large DA Dynamic Aperture increases by minimizing sextupole driving terms DA > (13 x 14mm) DA is large enough to consider injection without breaking 28 period lattice

  27. Momentum aperture also large Chromaticity correction yields +/- 3% with 3Qx resonance at >+3%

  28. Reconsidered TBA(24) Lattice TBA lattice with 7m ID’s and better magnet spacing increased C= 620m, mostly due to ID length

  29. Sextupole tuning harder to optimize Large higher order tune shifts make improvement in DA less predictable with existing expansion of Hamiltonian

  30. Adding a family of sextupoles Adding a 4th family of chromatic sextupoles and linear lattice tuning for reduced horizontal chromaticity yields large improvement in DA > (17 x 7 mm) enough for injection and starting error analysis

  31. Longitudinal parameters and RF The low emittance lattices have major impact on longitudinal parameters of the beam through the small value of the momentum compaction factor. RF Bucket Height Bunch length Momentum Compaction factor ~ Second stable bucket with energy separation When buckets distort and energy acceptance is asymmetric reducing lifetime DBA(28) TBA(24) <- Problem for 3% RF bucket height

  32. Undulator Impact on Lattice Properties Changes of the beam properties were calculated using 4 dipole-2 drift model for undulators in lattice programs Winagile and OPA These have the appropriate rms orbit in the undulators and were compared to analytic models which ignore I4 dependence. Calculated change of lattice parameter for per 2m undulator Tune shift may require some compensation with 20 undulators at Kmax

  33. Conclusions and Future Directions • TBA-24 preferred lattice: Lower emittance (achromatic), ERL and super-bend upgrade potential, lower DA and smaller • DBA-28 Larger DA and emittance, similar emittance (non-achromatic), less upgrade potential • Need to address small DA issues for all lattices: COSY Infinity, PTC, etc. to address nonlinear tune shifts Develop multi-cell cancellation for interleaved sextupole Try octupoles to reduce higher order tune shift with amplitude • Plan to address tolerance errors: alignment, gradient, multipoles • R&D effort: higher gradient dipoles, longer ID’s

  34. Facility Layout Building AreaArea [SF] First Floor Second Floor Total Linac Vault & Klystron Gallery 12,493 6,068 18,561 Utility Corridor 14,578 14,578 Accelerator Tunnel 51,563 51,563 Experimental Floor 111,230 111,230 Office/Lab 64,173 64,173 128,346 Office Block 11,055 8,945 20,000 TOTAL 265,092 79,186 344,278 IR Ring Office Block Office/Lab Space Experimental Floor Accelerator Tunnel Utility Corridor Linac Vault & Klystron Gallery 60 m Long Beamlines

  35. Siting NSLS Parking NSLS-II CFN N E W S

  36. Average X-ray Brightness NSLSNSLS-IIGain X25 U14 3x104 BM U14 5x106 BM BM 102 X1 U40 103 U5 U100 102-103 NSLSNSLS-II # Und 5 21+ # BM 30 24

  37. Average X-ray Flux NSLSNSLS-IIGain X25 U14 20 BM U14 300 BM BM 2 X1 U40 20 U5 U100 2-3

  38. NSLS-II: World Leading Brightness Current NSLS is off this chart at lower values

  39. NSLS-II: World Leading Flux

  40. NSLS-II: World Leading InfraredBrightness and Flux

  41. NSLS-II Beamlines and Instrumentation Tentative Insertion Device Beamline Plan 5 Macromolecular Crystallography 1 Coherent X-ray Scattering 1 X-ray Micro-beam diffraction 1 Small angle x-ray scattering 1 Materials science/time-resolved 1 Inelastic x-ray scattering 1 Resonant/Magnetic x-ray scattering 2 Superconducting Wiggler (6 beamlines) 4 Soft x-ray undulator beamlines 4 To be determined Optimized and Unique Endstation Instrumentation Automation, Robotics Ultra-High Pressures Ultra-High Magnetic Fields Very Low Temperatures Advanced, efficient, high thoughput, large area detectors Pixel Array Detector

  42. NSLS-II Preliminary Project Profile CONSTRUCTION CO OPERATIONS LLP PED CD Project Engineering & Design Conceptual Design Long Lead Procurement Operations! Construction Commissioning 2005 2006 2007 2008 2009 2010 2011 2012 Fiscal Year FTE –Years : 531 TEC: $393M FY04 TPC: $424M FY04

  43. NSLS-IIThe Future National Synchrotron Light Source Stay tuned for future development Enabling “grand challenge” science

More Related