1 / 9

Binocular Defocus Curve of Apodized Diffractive Multifocal IOL in Asian-Indian Eyes

Binocular Defocus Curve of Apodized Diffractive Multifocal IOL in Asian-Indian Eyes . Dr.A . Shetty ; Dr. M. K. Kummelil ; Dr. S.Nagappa Cataract and Refractive Lens Surgery Services Narayana Nethralaya,Bangalore ,India No Financial Disclosure. Purpose.

darena
Download Presentation

Binocular Defocus Curve of Apodized Diffractive Multifocal IOL in Asian-Indian Eyes

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Binocular Defocus Curve of Apodized Diffractive Multifocal IOL in Asian-Indian Eyes Dr.A. Shetty; Dr. M. K. Kummelil; Dr. S.Nagappa Cataract and Refractive Lens Surgery Services NarayanaNethralaya,Bangalore ,India No Financial Disclosure

  2. Purpose • To study the Binocular Defocus Curve and its implications for an apodized diffractive Multifocal IOL (MFIOL)

  3. Materials and Methods • 15 patients who had undergone bilateral implantation of RESTOR 3+ multifocal  IOL were included. • BSCVA for distance was estimated by subjective refraction at the end of 6 weeks post op.

  4. Materials and Methods • The best spectacle correction was placed in the trial frame. • Trial lenses ranging in power from +2 to 6 D were placed serially in front of both eyes in 1D increments. • Distance vision was recorded for each set of trial lenses

  5. Materials and Methods • A defocus curve was obtained by plotting the mean binocular visual acuities against 9 values of defocus (ranging from + 2.0 to - 6.0 D in 1 D steps).

  6. Results • 30 eyes of 15 patients • Best Corrected Visual Acuity(Decimal Scale) - • BCDV was 0.94 + 0.13 • IDV was 0.53 + 0.17 • BCNV was 0.97 + 0.08

  7. Results –Binocular Defocus Curve • The mean visual acuity improved from 0.522 logMAR with +2D to 0.0 logMAR with plano. • It dipped to 0.221logMAR with -1 and -2D • Improved marginally to 0.176logMAR with -3 D when the near add was neutralized. • Dipped to 0.954logMAR with -6 D.

  8. Conclusion • The minimal dip of the defocus curve suggests good range of vision and reasonable intermediate vision in patients implanted with the RESTOR 3+ multifocal IOL.