1 / 39

NYS TRUSS IDENTIFICATION LAW

NYS TRUSS IDENTIFICATION LAW. ..so that firefighters may be aware of the presence of any trusses. NYS TRUSS SIGNAGE LAW. Trusses are everywhere. Trusses And Fire. Thus you have no way of knowing how long before it fails!!!. They fail quickly when heated, in as little as 1-2 minutes!

Download Presentation

NYS TRUSS IDENTIFICATION LAW

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NYS TRUSS IDENTIFICATION LAW • ..so that firefighters may be aware of the presence of any trusses. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  2. NYS TRUSS SIGNAGE LAW Trusses are everywhere DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  3. Trusses And Fire Thus you have no way of knowing how long before it fails!!! • They fail quickly when heated, in as little as 1-2 minutes! • They fail without warning • They don’t get “spongy” before failing so “sounding” a roof is of no help You have no idea how long the truss has been being heated from the fire when you arrive on the scene. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  4. TITLE 19 (NYCRR)CHAPTER XXXIII - STATE FIRE PREVENTION & BUILDING CODE COUNCILSUBCHAPTER C - OTHER REGULATIONS DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  5. TRUSS IDENTIFICATION • In recognition that truss assemblies can, have and will fail when exposed to fire conditions, the following has been enacted to provide a system to notify firefighters of important information about structures including the presence of trusses. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  6. The system is a very simple one but, like anything else, can only be effective if all firefighters are keenly aware of it and have a good understanding as to how to read and interpret it. • Looking for this should be a standard part of every scene size up. • The first one at an incident to see this sign should announce it’s presence and contents so that everybody is made aware of this vital information. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  7. . Section 382-a of the Executive Law provides that commercial and industrial buildings and structures that utilize truss type construction shall be marked by a sign or symbol that informs persons conducting fire control and other emergency operations of the existence of truss construction. Section 382-a further directs the State Fire Prevention and Building Code Council to promulgate rules and regulations it deems necessary to carry into effect the provisions of the statute. This Part establishes certain requirements pertaining to the identification of buildings and structures that utilize truss type construction. Effective December 29, 200419 NYCRR Part 1264PART 1264 - IDENTIFICATION OF BUILDINGS UTILIZING TRUSS TYPE CONSTRUCTION1264.1 Introduction DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  8. 1264.3 Definition. For the purposes of this Part, truss type construction shall mean a fabricated structure of wood or steel, made up of a series of members connected at their ends to form a series of triangles to span a distance greater than would be possible with any of the individual members on their own. Truss type construction shall not include: (1) individual wind or seismic bracing components which form triangles when diagonally connected to the main structural system; and (2) structural components that utilize solid plate web members. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  9. 1264.4 Identification of truss type construction • a) Truss type construction shall be identified by a sign or signs in accordance with the provisions of this Part. • (b) Signs shall be affixed where a building or a portion thereof is classified as Group A, B, E, F, H, I, M, or S occupancy, and in hotels and motels classified as Group R-1 or R-2 occupancy, in accordance with the provisions for the classification of buildings set forth in chapter 3 of the Building Code of New York State (see 19 NYCRR Part 1221). • (c) Signs shall be provided in newly constructed buildings that utilize truss type construction and in existing buildings where an addition that extends or increases the floor area of the building utilizes truss type construction. Signs shall be affixed prior to the issuance of a certificate of occupancy or a certificate of compliance. Note; one or two family dwellings are not covered by this law nor is existing construction unless it has had an addition installed after the effective date. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  10. Abbreviated Summary • A= Assembly • B=Businesses • E=Educational up through grade 12 • F=Factory • H-High Hazard=manufacturing/storage using materials with “high” physical or health hazards • I=Institutional • M=Mercantile (store) • R=Residential • S=Storage • U=Misc. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  11. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  12. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  13. (d) Signs identifying the existence of truss construction shall consist of a circle 6 inches (152.4 mm) in diameter, with a stroke width of ½ inch (12.7 mm). The sign background shall be reflective white in color. The circle and contents shall be reflective red in color, conforming to Pantone matching system (PMS) #187. Where a sign is directly applied to a door or sidelight, it may be a permanent non-fading sticker or decal. Signs not directly applied to doors or sidelights shall be of sturdy, non-fading, weather resistant material. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  14. e) Signs identifying the existence of truss construction shall contain the roman alphanumeric designation of the construction type of the building, in accordance with the provisions for the classification of types of construction set forth in section 602 of the Building Code of New York State (see 19 NYCRR Part 1221), and an alphabetic designation for the structural components that are of truss construction, as follows: • “F” shall mean floor framing, including girders and beams • “R” shall mean roof framing • “FR” shall mean floor and roof framing • The construction type designation shall be placed at the twelve o’clock position over the structural component designation, which shall be placed at the six o’clock position. • (f) Signs identifying the existence of truss construction shall be affixed in the locations specified in Table I-1264 DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  15. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  16. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  17. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  18. B=Business (this info is extra- not required by the “law”) Type 3-Ordinary Construction Trusses in roof assembly The 'B' is because it is a Type IIIB building; these are the classifications the Uniform Code uses (IA, IB, IIA, IIB, IIIA, IIIB, IV, VA, VB), found in Table 302 of the Building Code of New York State. This is not required to be on this label but often is included. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  19. Unprotected steel: Expands at 1,000*f, Fails at 1,300*f DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  20. II=Unprotected steel R=Roof Trusses DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  21. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  22. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  23. The Law and the FD • The “Law” makes this vital info available to you. Now it’s up to you and your department to use it. • Enter this info into every pre-plan; the presence and/or absence of any trusses. • It should be an SOP that the first firefighter who sees one of these signs at an incident announces this information on the radio so everybody becomes aware. • Conduct “walk throughs” of these structures • Conduct table top exercises so everybody knows how to deal with incidents in these (and all other) structures. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  24. 1264.2 Enforcement. • (a) Subdivision 4 of section 382-a of the Executive Law directs local governments to provide for enforcement of the statute. Enforcement of section 382-a of the Executive Law shall include enforcement of the provisions of this Part. A fee of fifty dollars shall be paid by the owner of a building with truss type construction to the authority having jurisdiction for enforcement of section 382-a of the Executive Law prior to the issuance of a building permit. • (b) This Part shall not apply within a city with a population of one million or more persons. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  25. 1264.3 Definition. • For the purposes of this Part, truss type construction shall mean a fabricated structure of wood or steel, made up of a series of members connected at their ends to form a series of triangles to span a distance greater than would be possible with any of the individual members on their own. Truss type construction shall not include: • (1) individual wind or seismic bracing components which form triangles when diagonally connected to the main structural system; and • (2) structural components that utilize solid plate web members. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  26. THE GOOD PART IS. • Now, any structure built or added on to after the effective date (12/29/04) that has any trusses in it, will be required to display this signage. • This should make every firefighter aware of the presence of trusses. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  27. BUT……… • The law is based on the weakest link. • Example; a formerly Type I building gets an addition that features wooden structural members. • That changes to entire structure to Type V. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  28. RECOMENDATION • Use this signage like anything else; remember it but don’t take it as absolute gospel • Make sure your pre-plans are always up to date • Make sure all your personnel know how to read and use a pre-plan • Use your pre-plans !! DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  29. Also remember.. • It doesn’t apply to structures built before 12/29/04 unless they have an addition put onto them. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  30. To Access the Law: • http://www.dos.state.ny.us/code/part1264.htm DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  31. The following slide shows a time lapsed series of pictures from a test burn on a wood truss. It failed exactly 5 minutes after the fire was ignited. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  32. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  33. http://faculty.sunydutchess.edu/walsh/videos/TRAINING%20CLIPS/trainingclips.htmhttp://faculty.sunydutchess.edu/walsh/videos/TRAINING%20CLIPS/trainingclips.htm • Click on the hyperlink above and then click on the button labeled ”Truss Burn Demo” to see a truss fail under fire conditions. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  34. The NYS “version” contains the building construction type. The system NIOSH recommends doesn’t. DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  35. Let’s See What You’ve Learned? DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  36. What is this telling you? • I=Type 1 construction; Fire Resistive • R=Trusses in Roof assembly I R DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  37. What is this telling you? • IV=Heavy Timber • FR=Trusses in floor & roof assemblies IV FR DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  38. What is this telling you? • V=Type 5 construction; wood frame • F-Trusses in floor assembly V F DCC FIRE SCIENCE PROGRAM ver. 12/14/09

  39. Be Safe, Be Careful, Be Aware… THE END DCC FIRE SCIENCE PROGRAM ver. 12/14/09