An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2010 Standards for Accessible Design Presented by Ray Petty Great Plains ADA Center Wichita, Kansas May 24, 2012

  2. Update on DOJ’s ADA Standards • Published in the Federal Register as a Standard September 15, 2010 Effective Dates: • Sept 15, 2010- Entities may choose either 1991 Standard or the 2010 Standard • March 15, 2012- 2010 Standard will be the only ADA standard available

  3. Updated DOT Standards for Transit Facilities Updated ADA standards adopted by DOT (effective Nov. 2006) Apply to transportation facilities: • Bus stops and stations • Rail stations • Airports

  4. Updated DOT Standards for Transit Facilities Same as updated ADAAG, except for clarifications/ modifications: • accessible routes (206.3) • detectable warnings on curb ramps (406.8) • bus boarding areas (810.2.2), and • rail station platforms (810.5.3).

  5. ABA Standards • Similar update of Architectural Barriers Act (ABA) standards • Applies to federally funded facilities • ADA and ABA guidelines harmonized – updated standards more consistent

  6. Updated ABA Standards Four agencies maintain ABA Standards: • GSA - most ABA facilities (May 06) • USPS - postal facilities (Oct 05) • DOD - military facilities (Oct 08) • HUD – housing (update pending)

  7. “What standards do I follow?” First response remains: What kind of project/ facility is it?

  8. Applicable ADA Standards • Places of public accommodation, commercial facilities (Title III) and state & local government facilities (Title II): DOJ’s updated standards • Transportation facilities: DOT’s updated standards

  9. Updated ADAAG Application and General Scoping

  10. New Format • New numbering system • New figures (informational only) • All dimensions in text (not just in figures) • New advisory notes follow provision

  11. ADAAG Supplements Previous supplements included: • State & Local Gov’t Facilities (1998) • Children’s Environments (1998) • Play Areas (2000) • Recreation Facilities (2002) These are now integrated into the ADA-ABA Guidelines, now called 2010 Standards.

  12. Harmonization • ICC/ANSI A117.1-2003 IBC 2003

  13. Side-by-side Comparisons New ADAAG, original ADA standards, and IBC/ ANSI www.access-board.gov/ada-aba/comparison/comparison.pdf

  14. CHAPTER 1 Application and Administration 101 – Purpose 102 – Dimensions for Adults and Children 103 – Equivalent Facilitation 104 – Conventions 105 – Referenced Standards 106 – Definitions

  15. Conventions • Dimensions – range instead of absolute dimension where possible • Construction and manufacturing tolerances • Calculation of percentages • Figures – are informational; the text governs!

  16. Ranges instead of absolute dimensions Water closet centerline (16-18”) Width of ambulatory accessible stall (35”- 37”)

  17. Some absolute dimensions remain Transfer shower stall (36” x 36”) and combination transfer/roll-in design with seat on front wall (36” deep) measured to center points; manufacturing tolerances recognized

  18. Conventional Industry Tolerances For field conditions and manufacturing process (not design work) • Don’t apply to ranges (min. and max.) • For absolute dimensions or where only a min. or max. specified • Avoid specifying tolerances (e.g., “36 inches plus or minus X inches”) • Design should specify above max. or below min. (to factor in tolerance)

  19. Referenced Standards • powered doors (ANSI/BHMA A156.10 & A156.19) • elevators and lifts (ASME A17.1 & A18.1) • egress (IBC) • alarms (NFPA 72) • play surfacing & equipment (ASTM standards)

  20. CHAPTER 2General Scoping and Exceptions

  21. Application (201) Premise: All areas of newly designed/ constructed facilities are to comply, unless indicated Exceptions more thoroughly covered

  22. Existing Buildings and Facilities (202) • Additions • Alterations (specific exceptions now located at relevant provision) • Primary Function Areas – Path of Travel • Qualified Historic Facilities

  23. ABA Application & Scoping (Chapters F1 & F2) Consistent with ADA document except for: • modifications and waivers (F103) • definitions (F106) • additions (F202.2) • leased facilities (F202.6) • employee work areas (full coverage) • existing elements (F203.2)

  24. General Exceptions (203) • construction sites • raised areas • limited access spaces • machinery spaces • single occupant structures (e.g., toll booths) • certain common use spaces in detention and correction facilities and residential facilities • employee work areas • various spaces in recreation facilities

  25. ADA Work Areas • “approach, entry, & exit” • circulation paths (in areas ≥ 1000 sq ft) • means of egress • visual alarm • connection

  26. ADA Employee Work Areas Circulation paths = accessible unless: • Work areas < 1000 sq. ft. defined by permanent partitions, casework, counters, or furnishings • Paths, when integral part of equipment • exterior areas fully exposed to the weather

  27. Building Blocks (Chapter 3) • Floor or Ground Surfaces • Changes in Level • Turning Space • Clear Floor/ Ground Space • Knee & Toe Clearance • Protruding Objects • Reach Ranges • Operable Parts

  28. Turning Space (304) • clarification: overlap of turning space is allowed where knee/ toe clearance is provided • doors can swing into turning space

  29. Turning Space (304)

  30. Turning Space (304) Overlap permitted for only one arm of T-shaped space

  31. Knee Space (306)

  32. Toe Space (306)

  33. Reach Ranges (308) Max. Reach – 48”Min. Reach – 15”(forward & side)

  34. Operable Parts (205) New or clarified exceptions for: • those used only by maintenance personnel • elec./ comm. receptacles – dedicated use • floor electrical receptacles • certain additional outlets above counters • HVAC diffusers • Redundant controls (except light switches)

  35. Accessible Routes (Chapter 4) • Accessible Route Components • walking surfaces • doors, doorways, gates • ramps • curb ramps • elevators • limited use/ limited application elevators • private residence elevators • platform lifts

  36. Accessible Routes (206) Where required: • Site arrival points • Within sites (but not required if no pedestrian route is provided) • Between stories (elevator exceptions) • Space and elements • Specific spaces (e.g., restaurant & cafeteria, performance area, press box)

  37. Press Boxes New exception: • if 500 sq ft or less (aggregate area) • on bleachers entered on 1 level • free-standing – elevated 12’ or more

  38. Entrances Route to entrances to coincide with general circulation routes to maximum extent feasible

  39. Entrances Communication devices should have both visual and audible signals (Required in new version)

  40. Walking Surfaces (403) (Portions of accessible routes that slope no more than 1:20) • Minimum separation (48”) between reduced clear widths • Handrails along walking surfaces are required to comply

  41. Doors - Clearances Clearance at doors in thick walls or that are recessed (8” max. offset) Pull side clearance, forward approach

  42. Doors - Clearances Push side clearance required at doors with both closer & latch

  43. Doors, Doorways, & Gates (404) Other changes: • Doors in series • Hardware height • Limited projections into clear width • Closing speed • Surface (push side) • Vision lights

  44. Doors in Series New version allows both sets of doors to swing into space (with proper separation)

  45. Doors in Series Where doors are automated, provide wheelchair space at controls outside door swing

  46. Entrances • Automated openers recommended for exterior doors • Required for Federal GSA buildings

  47. Automatic & Power Assisted Doors & Gates (404.3) Industry standards referenced: • Full-powered: ANSI/BHMA A156.10 (1999) • Low-energy and power-assisted: ANSI/BHMA A156.19 (1997 or 2002) New provisions for break-out opening, clear floor space at controls

  48. Automatic & Power Assisted Doors & Gates (404.3) 404.3.6 Break Out Opening. Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated in emergency mode.

  49. Ramps (405) • Slope - 1:12 max • Handrails (> 6” rise) • both sides • 12” extensions • 34” to 38” height This is not a compliant ramp!

  50. Ramps (405) • Level landings (1:48 max.) • Edge protection (clarified specs) • Exceptions for ramps in work areas (width, handrails)