270 likes | 377 Views
Production cross sections for (n ,g) reactions on 88 Sr, 102 Pd, 124 Xe, 130 Te, 152 Sm, 165 Ho and 191 Ir leading to therapeutic isotopes. IAEA Research Contract No. 12425. E. Běták Institute of Ph ysics SAS, Bratislava, Slovakia. Gamma emission in pre-equilibrium reactions:
E N D
Production cross sections for (n,g) reactions on 88Sr, 102Pd, 124Xe, 130Te, 152Sm, 165Ho and 191Ir leading to therapeutic isotopes IAEA Research Contract No. 12425 E. Běták Institute of Physics SAS, Bratislava, Slovakia Final RCM on Therapeutic Radionuclides, IAEA, May/June 2006
Gamma emission in pre-equilibrium reactions: Single-particle radiative mechanism (Běták & Dobeš, Akkermans & Gruppelaar) Probability of g emission (E1 transitions) Spin variables (Obložinský & Chadwick) Final RCM on Therapeutic Radionuclides, IAEA, May/June 2006
Computer codes with pre-equilibrium g emission and released to public PEQGM (1983) (spin-independent version, obsolete already) GNASH (1992, 1995) (also spin variables and discrete levels) (recent versions strongly improved and enlarged, but not available anymore) PEQAG (1989) (update of PEQGM) PEGAS (1993) (also spin variables) & DEGAS (plus discrete levels) “Do-all” nuclear reactions codes with pre-eq. g EMPIRE-II version 2.18 Mondovi (2002) version 2.19 Lodi (2005) TALYS (2005) Final RCM on Therapeutic Radionuclides, IAEA, May/June 2006
Results calculated and prepared as ENDF files. (One file received from Choi). But: Final RCM on Therapeutic Radionuclides, IAEA, May/June 2006
Unsolved EMPIRE problems: What is the origin of the differences between TALYS and EMPIRE, if they are so similar? GCASC does not work (spectra with GCASC=1 are identical to those =0) DEGAS not used for gammas. Why (and how to correct it?) Why the nonphysical sharp decrease above 18 MeV? Final RCM on Therapeutic Radionuclides, IAEA, May/June 2006
CONCLUSIONS Pre-eq. g emission useful to describe cross sections and g spectra, if one is not just in double-magic region. Therein, DSD (or CDSD) model is more reliable. Physically both describe the same situation with emphasis on different aspects of the reality. Two released “do-all” nuclear codes TALYS and EMPIRE give similar results away of closed shells. In their vicinity, there is no clear preference of either of the codes which might be universally valid. Final RCM on Therapeutic Radionuclides, IAEA, May/June 2006
Related publications: • Běták et al.: Neutron radiative capture (pre-equilibrium approach). NEMEA (2003) Proceedings, p. 41 • Běták et al.: Activation cross sections for reactions induced by 14 MeV neutrons on natural tin … Radiochim. Acta 93 (2005), 311 • Běták et al.: Possibilities of production of diagnostic isotope 111In using neutron- and proton-induced reactions … NEMEA-2 (2004) Proceedings, p. 69 • Běták: Model calculations of radiative capture … CGS-12 (2005) Proceedings, p. 226 • Běták et al.: New generator method of pure 111In production in the proton-induced … (submitted, 2006) Final RCM on Therapeutic Radionuclides, IAEA, May/June 2006
Thank you Final RCM on Therapeutic Radionuclides, IAEA, May/June 2006
Sr-88 Koehler (2000) 5320 points up to 350 keV isolated points in the Koehler’s region Hughes (1950) 1 point at 1 MeV (2.1 mb) Pd-102 no usable data point Xe-124 no usable data point Te-130 many points up to 10 keV about 40 points 10 keV to 20 MeV (60 mb to 0.6 mb) about 25 points 10 keV to 6 MeV (20 b to 2 b (!)) Sm-152 two sets (plus isolated points) 3 keV to 3 MeV (1.5 b to 50 mb) one set (4 points) 25 keV to 1 MeV (600 b to 120 b (!)) Ho-165 several sets of data up to 20 MeV (10 b to 0.7 mb) one set (5 points) 20 keV to 1 MeV (1500 b to 100 b (!)) Ir-191 several sets up to 20 (25) MeV (EXFOR v. 1.62 – June 2004) Final RCM on Therapeutic Radionuclides, IAEA, May/June 2006