1 / 36

A CLU ster COU nting D rift C hamber for ILC

A CLU ster COU nting D rift C hamber for ILC. F.Grancagnolo, INFN – Lecce. F. Grancagnolo. INFN – Lecce --- CLUCOU for ILC ---. outline. Requirements for tracking at ILC Cluster Counting 4 th Concept CLUCOU Drift Chamber 4 th Concept MUon Detector.

Download Presentation

A CLU ster COU nting D rift C hamber for ILC

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. A CLUster COUnting Drift Chamber for ILC F.Grancagnolo, INFN – Lecce

  2. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- outline • Requirements for tracking at ILC • Cluster Counting • 4thConcept CLUCOU Drift Chamber • 4thConcept MUon Detector

  3. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- borrowed from:

  4. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- From Gluckstern: @ ILC, for B = 5 T, L = 1.5 m N = 150 , L ~ 2m (1 cm2 hex. cells) 60.000 sense wires 120.000 field wires

  5. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- Multiple scattering contribution (equivalent L/X0): 60.000 20 mm W sense wires → 1.8 × 10-3 (X0 = 0.35 cm) 120.000 80 mm Al field wires → 2.2 × 10-3 (X0 = 8.9 cm) 2 m gas (90% He + 10% iC4H10) → 1.5 × 10-3 (X0 = 1300 m) Equivalent L/X0 = 5.5 × 10-3 Sagitta measurement contribution (in  plane):

  6. this CLUCOU Drift Chamber F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- Momentum Resolution 4thConcept TPC (160 pads) 4thConcept TPC + 5 pixel planes

  7. 2 cm drift tube 90%He-10%iC4H10 few x 10 gain 5 F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- CLUster COUnting Dt : time separation between consecutive ionization clusters, as a function of their ordered arrival time, for different impact parameters. (caveat: electrons!) i+1,i In this He mixture , provided that: sampling frequency of signals > 2 Gsa/s and rise (and fall) time of single electron signals < 1ns single electron counting is possible.

  8. b=0 b=1 cm 10 mV 500 ns tmax=1.6 ms tfirst tlast t0 trigger signal F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- CLUster COUnting MC generated events: 2cm diam. drift tube gain = few x 10 gas: 90%He–10%iC4H10 no electronics simulated vertical arbitrary units cosmic rays triggered by scintillator telescope and readout by: 8 bit, 4 GHz, 2.5 Gsa/s digital sampling scope through a 1.8 GHz, x10 preamplifier

  9. tfirst t0 Ncl! Ncl-i i-1 Ncl (Ncl-i)! (i-1)! F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- CLUster COUnting CLUster COUnting For a given set up, and a digitized pulse (tlast is constant with a spread < 20 ns) t0 = tlast–tmax gives the trigger time bf = ∫ v(t) dt first approx. of impact parameter b (c/2)2 = r2 - bf2 length of chord Ncl = c / (l(bg) ×sinq) expected number of cluster Nele = 1.6 x Ncl expected number of electrons (to be compared with counted one) {ti } and {Ai }, i=1,Nele ordered sequence of ele.drift times and their amplitudes P(i,j), i=1,Nele, j=1,Ncl probability i-th ele.  to j-th cl. Di (x) = (1-x) x probability density function of ionization along track

  10. sb Fit to resolution function: (from KLOE data) l = 770 14 mm np = 12.9  0.1 cm-1 sD = 140 mm cm-1/2 st = 4.8  0.2 ns b F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- • Each cluster contributes to the measurement of the impact parameter with an • independent estimate weighted according to the Poisson nature of the process • and the electron diffusion along the drift path. • The resolution on the impact parameter, sb, improves with the addition of each • cluster beyond the first one. • It, however, saturates at a value of 30-35 mm, convolution of: • spread in mechanical tolerances (position of sense wire; gravitational sag; electrostatic displacement) • timing uncertainties (trigger timing; electronics calibration; t0) • degree of knowledge of time-to-distance relation • instability of working parameters (HV, gas temperature and pressure, gas mixture composition) Reasonable to assume sb = 50 mm per sense wire

  11. experiment: • p/m = 1.3 s • theory:trunc. mean: • p/m = 2.0 sp/m = 0.5 s gas mixture = 95%He+5%iC4H10 Ncl = 10/cm beam test measurements p = 200 MeV/c CLUCOU chamber expected dNcl/dx resolution for a 2 m m.i.p. at 13 cluster/cm: s(dNcl/dx)/(dNcl/dx) = 2.0 % F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- Particle Identification

  12. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- 4thConcept ILC Drift ChamberLayout and assembly technique Length: 3.4 m at r = 22.5 cm 3.0 m at r = 147.0 cm Spherical end plates: C-f. 12 mm + 30 mm Cu (0.047 X0) Inner cylindrical wall: C-f. 0.2 mm + 30 mm Al (0.001 X0) Outer cylindrical wall: C-f./hex.cell. sandwich held by 6 unidir. struts 0.020 X0) Retaining ring Stiffening ring TOTAL = 0.028 X0 Gas = 0.0015 X0 Wires = 0.0040 X0

  13. 4thConcept ILC Drift ChamberLayout F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- Hexagonal cells f.w./s.w.=2:1 cell height: 1.00  1.20 cm cell width: 6.00  7.00 mm (max. drift time < 300 ns !) 20 superlayers, in 200 rings 10 cells each (7.5 in average) at alternating stereo angles ±72  ±180 mrad (constant stereo drop = 2 cm) 60000 sense w. 20 mm W 120000 field w. 80 mm Al “easy” t-to-d r(t) (few param.) >90% sampled volume

  14. Summary for ILC F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- • A drift chamber à la KLOE with cluster counting (≥ 1GHz, ≥ 2Gsa/s, 8bit) • uniform sampling throughout >90% of the active volume • 60000 hexagonal drift cells in 20 stereo superlayers (72 to 180 mrad) • cell width 0.6 ÷0.7 cm (max drift time < 300 ns) • 60000 sense wires (20 mm W), 120000 field wires (80 mm Al) • high efficiency for kinks and vees • spatial resolution on impact parameter sb = 50 mm (sz = 300 mm) • particle identification s(dNcl/dx)/(dNcl/dx) = 2.0% • transverse momentum resolution Dp/p = 2·10-5 p 5·10-4 • gas contribution to m.s. 0.15% X0, wires contribution 0.40% X0 • high transparency (barrel 2.8% X0, end plates 5.4%/cosq X0+electronics) • easy to construct and very low cost • is realistic, provided: • cluster counting techique is at reach (front end VLSI chip) • fast and efficient counting of single electrons to form clusters is possible • 50 mm spatial resolution has been demonstrated

  15. G.V. Fedotovich and the CMD-3 Collaboration F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- Drift Chamber for CMD-3 Detector @ VEPP-2000, Novosibirsk

  16. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- to be presented at

  17. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- during CLUCOU Proposal presented @

  18. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- rendering of first two superlayer stereo

  19. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC ---

  20. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC ---

  21. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC ---

  22. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- fraction of hit cells per ring highest multiplicity events: 300 cells superlayer 680 cells ≥ 300 tracks per such event average number of tracks crossing a hit cell

  23. diameter x length 12.8 m x 15.4 m 7.7 m 6.4 m F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- 4thConcept layout

  24. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- 4thConcept Dual Solenoid m - BARREL MUD barrel MUD E C N A D P CLUCOU chamber

  25. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- m-system basic element: drift tube • radius 2.3 cm • filled with 90% He – 10% iC4H10 @ NTP • gas gain few × 105 • total drift time 2 µs • primary ionization 13 cluster/cm≈ 20 electrons/cm total • both ends instrumented with: • > 1.5 GHz bandwith • 8 bit fADC • > 2 Gsa/s sampling rate • free running memory • for a • fully efficient timing of primary ionization: cluster counting • accurate measurement of longitudinal position with charge division • particle identification withdNcl/dx

  26. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- Drift tube end plug detail

  27. ×18 1750 tubes 70 cards 650 tubes 26 cards ×18 ×36 550 tubes 22 cards F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- Modularity

  28. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- 1/3 of barrel ×3 10500 tubes 420 cards

  29. 1440 tubes 1632 channels 76 cards ×6 F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- 1/3 end cap

  30. ×2 F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- One end cap

  31. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- Full muon system Barrel: 31500 tubes 21000 channels 840 cards End caps: 8640 tubes 9792 channels 456 cards Total: 40140 tubes 30792 channels 1296 cards

  32. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- m+m−at 3.5 GeV/c

  33. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- Downscaling to SuperB

  34. F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- SuperB Drift ChamberLayout and assembly technique Length × Diameter : ~ 2.8 m × 0.8 m Spherical end plates: C-f. 6 mm equivalent + 30 mm Cu (0.024 X0) Inner cylindrical wall: C-f. 0.2 mm + 30 mm Al (0.001 X0) Outer cylindrical wall: C-f./hex.cell. sandwich held by 6 unidir. struts 0.020 X0) Retaining ring Stiffening ring TOTAL = 0.023 X0 Gas = 0.0014 X0 (80%He+20%iC4H10) Wires = 0.0004 X0

  35. SuperB Drift ChamberLayout F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- Hexagonal cells f.w./s.w.=2:1 cell height: ~ 1.70 cm cell width: ~ 10.mm (max. drift time < 700 ns !) 10 superlayers in 100 rings 10 cells each (7.5 in average) at alternating stereo angles ±72  ±130 mrad (constant stereo drop = 2 cm) 12000 sense w. 20 mm W 24000 field w. 80 mm Al “easy” t-to-d r(t) (few param.) >90% sampled volume

  36. Summary for SuperB F. Grancagnolo. INFN – Lecce--- CLUCOU for ILC --- • A drift chamber à la KLOE with cluster counting (≥ 1GHz, ≥ 2Gsa/s, 8bit) • uniform sampling throughout >90% of the active volume • 12000 hexagonal drift cells in 8 stereo superlayers (72 to 130 mrad) • cell width ~ 1.0 cm (max drift time < 700 ns) • 12000 sense wires (20 mm W), 24000 field wires (80 mm Al) • high efficiency for kinks and vees • spatial resolution on impact parameter sb = 50 mm (sz = 400 mm) • particle identification s(dNcl/dx)/(dNcl/dx) = 2.3% • transverse momentum resolution Dp/p = 1.0·10-3 p 1.5·10-3 • gas contribution to m.s. 0.14% X0, wires contribution 0.03% X0 • high transparency (barrel 2.2% X0, end plates 2.6%/cosq X0+electronics) • easy to construct and very low cost • is realistic, provided: • cluster counting techique is at reach (front end VLSI chip) • fast and efficient counting of single electrons to form clusters is possible • 50 mm spatial resolution has been demonstrated