160 likes | 614 Views
C300 Fluid Control Valves. Non Regulating Valve. C300 Non regulating On/Off Control. Options Pneumatic / Electric Control Electric / Hydraulic Control. Uses Simple Control of Water spray Control of Foam Skids Control of Monitors. Low pressure loss Surge Protection.
E N D
C300 Fluid Control Valves • Non Regulating Valve
C300 Non regulating On/Off Control • Options • Pneumatic / Electric Control • Electric / Hydraulic Control • Uses • Simple Control of Water spray • Control of Foam Skids • Control of Monitors • Low pressure loss • Surge Protection
C300 Basic Body for all Applications Pressure sensing & priming Port Priming water & sensing Port Cavity Port Interface block Drain Port 1/2” N.P.T. Inlet Cone
C300 Non Regulating ON/Off Valve - Closed Position Solenoid Valve Air pressure ‘ON’ Port CP2 Closed Port CP4 Open Port CP5 Open • Actuator Ports Not Shown • CP1 - Plugged • CP3 - Plugged Water pressure in cavity WATER SUPPLY Inlet water Pressure maintains the sleeve in the closed position. C300 shoe To drain or emergency release Refer to data sheets D3000 D3001
C300 Non Regulating ON/Off Valve - Open Position Air pressure ‘OFF’ Solenoid Valve Multi way actuator Port CP2 Opens to vent Port CP4 Closes preventing water entering cavity Port CP5 Open - water vents cavity to drain • Actuator Ports Not Shown • CP1 - Plugged • CP3 - Plugged Water enters the system pipe work WATER SUPPLY Inlet water Pressure lifts the rubber sleeve into the open position. C300 shoe To drain or emergency release Refer to data sheets D3000 D3001
C300 Non Regulating Valve - Electro hydraulic ICO4S Solenoid valve Interface plate Cu Ni 90/10 Tube Ali Br fittings Basic body assembly
C300 Non Regulating ON/Off Valve with ICO4 Solenoid valve • Solenoid - Material Options • Cast Iron • Ali Bronze • St.Steel 316 • Specify Input Voltage • 240/110/24v • Normal Status Options • De-energised • or Energised Upon Activation the Solenoid switches ports to vent the cavity and allow the valve to open. Port pressurises cavity during Normal status. Mechanical Latch available Inlet water Pressure lifts the rubber sleeve into the open position. WATER SUPPLY C300 shoe To drain or emergency release Refer to data sheets D3000 D3113
Non Regulating Valve Options / Components Inline strainer Opening & closing speed / flow control. For actuator Multi-way see Data Sheet D5200 For Solenoid see IC04 Solenoid Data Sheet Data sheet D3004
C300 Integral On/Off Valve Installation Integral pneumatic actuator Air Supply Solenoid valve Drain port
C300 Non Regulating with Integral ON/Off Actuator - Closed Position Solenoid Air Pressure ‘ON’ 3-12 bar • Manifold Block • Integral Strainer • Opening / Closing -Speed Control Water enters cavity Water pressure maintains the sleeve in the closed position. WATER SUPPLY C300 shoe To drain or emergency release Refer to data sheet D3002
C300 Non Regulating with Integral ON/Off Actuator - Open Position Air Supply ‘OFF’ below 3 bar . Port closes to prevent pressure in cavity Spool vents the cavity port Inlet water Pressure lifts the rubber sleeve into the open position. WATER SUPPLY Mechanical Latch available for manual re-set C300 shoe To drain or emergency release Refer to data sheet D3002