660 likes | 873 Views
Welcome Normalab. Overview august 2011. Aug. 2011. Tamson Products 2011 Content of presentation. Tamson Key benefits Bit of Competition Tamson product portfolio Circulators / water baths Viscosity Accessories ASTM Equipment Calibration Baths. 2. Aug. 2011. Tamson founded in 1878.
E N D
Welcome Normalab Overview august 2011
Aug. 2011 Tamson Products 2011Content of presentation • Tamson • Key benefits • Bit of Competition • Tamson product portfolio • Circulators / water baths • Viscosity • Accessories • ASTM Equipment • Calibration Baths 2
Aug. 2011 Tamson founded in 1878 • P.M. Tamson bv founded in 1878 by Mrs. Tamson in the Hague, the Netherlands. • Distribution of laboratory supplies initially. • From 1950’s also manufacturing Tamson thermostatic baths and circulators. • In 1992 sold to Fisher Scientific USA. • Fisher sold assets of manufacturing of Tamson Instruments in August 1998 – Fisher kept sales of general laboratory supplies. • Assets were put in new company – Labovisco bv. • 2004 Labovisco is renamed in Tamson Instuments bv. • 2008 Moved to new building in Bleiswijk which is own property 3
Aug. 2011 Tamson focuses 100% on instruments • Privately owned by a group of 2 shareholders. • Headquarters and manufacturing in Bleiswijk, the Netherlands. • Engineering, final assembly, sales and marketing done by the Tamson organization. • Basic manufacturing outsourced to third parties. 4
Aug. 2011 Markets ASTM oil – testing 75% Chemical industry 15% Quality&testing 7% Bio industry 3% 5
Aug. 2011 Why Tamson (key benefits)? • Price value • Stainless steel, Teflon • Reliability • Robustness • Accurate control • Safety features • 130 years of experience • Products conform to CE regulation • Dynamic company, easy to communicate 6
Aug. 2011 Competition • Julabo • Haake Neslab (Thermo Scientific) • Huber • Lauda • Grant, Techne, Lawler, FTS, • Cannon Instruments • Koehler Instruments • PolyScience 7
Aug. 2011 Results since 1998 have been good • Since 1998 growth in turnover has been some 5..10% per year. • More then 60 dealers and distributors around the world. • Product portfolio has grown significantly. First we have added coolers and circulators. Now we are adding calibration baths and products for petrochemical market. • Continuous intensive investments in research & development and product improvement. • Supplier of OEM-units. 8
Aug. 2011 Tamson product portfolio -80°C .. 250°C • Circulators and water baths • Heating • Cooling • Viscometer baths (ASTM D445, IP71) • High temperature • Low temperature • Accessories • Bath fluids • Viscometers capillaries (ASTM D445, D2171), holders and hanger • 8-channel stopwatch • ASTM thermometers (ASTM E1) and holders • Digital Contact thermometers for ASTM D445 • Reference standards • Performance pump • Tubing and manifold • Other Petrochemical Equipment (NEW) • Calibration baths (NEW) 9
Thermometer calibration Pre heating samples Sensor calibration Experiments Aug. 2011 Heating CirculatorsApplications 10
Aug. 2011 Heating Apparatus and application(High temperature) • Tamson Bracket (TB) • Tamson Circulator (TCxx) 11
Aug. 2011 Tamson Bracket (TB) • Completely stainless steel • Width can be adjusted from 186-422 mm • Auto tuning, high precision • Heater 1100W • Pump 7 L/min • Easy to operate • Fluid level detection • Cooling coil* • Heater 1600W* • RS232* • *Optional General purpose To replace old thermostatic units Heating of special bath which the customer is already using. 12
Aug. 2011 Tamson Circulator TCxxbTC6b, TC10b, TC20b • Bath stainless steel • 6,10 or 20ltrs • Range ambient .. 200°C • Level indication • Bath drain • Cooling coil • Levelling platform* • RS232* • *Optional Applications: Heavy duty Quality testing Work bench Small footprint General purpose 13
Aug. 2011 Tamson Circulators TCxxb • TC6b, TC10b and TC20b can be used as: • Circulator through external circulation • Water baths for all kind of applications Very strong levelling platform anchored in the 4 corners of the bath. 14
Aug. 2011 Tamson Circulator TCxxTC16, TC40 and TC58 • Bath stainless steel • Cooling coil • Precise control • Temperature range from ambient up to 250°C • Pump 7,5 L/min • Auto tune, high precision • Display readout in 0.1°C (controller has a accuracy of 0.01°C) • Levelling platform* • RS232* • *Optional TC16 16 liters TC40 40 liters TC58 58 liters Applications: Heavy duty Quality testing Large volumes High temperatures 15
Aug. 2011 Tamson Circulator TC1616 liters bath • Options • RS232 communication (readout of 0.01°C with free Tamson software). • Remote PT100 • Additional heater 1500W • Bath drain (standard included) • Pressure/suction pump • Performance pump 16 L/min • Levelling platform Can be used as a circulator and a water bath. 16
Aug. 2011 Tamson Circulators TC40/TC5840/58 liters bath • Options • RS232 communication (readout of 0.01°C with free Tamson software). • Remote PT100 • Bath drain (standard included) • Pressure / suction pump • Performance pump 16 L/min • Levelling platform + lid • Gabled lid (so no condensation in samples). • Top lid with cover of 2 sets of 9 rings • Top lid with cover of 6 sets of 6 rings Can be used as a circulator and a water bath. 17
Aug. 2011 Heat removal circulators(Low temperature) TLC10, TLC15, TLC30, TLC40, TLC80, TLC80-DP and TLC90. • Ambient .. -90°C • RS232 communication • External circulation • Bath • Drain • Level indication 18
Aug. 2011 Heat removal(A few applications) Flash Point Viscosity Cold Filter Plugging Point General Laboratory -Experiments -Refractometers -Rotary Evaporators -Etc. Cloud & Pour Point Circulation 19
Aug. 2011 Tamson Low-temperature CirculatorTLC10-3 • Stainless steel • -10..60°C • Optional -10..150°C • Stability better than ± 0.05°C • Bath drain • Level detection • RS232, free software • Can be used as small bath • Bath volume 3 L • Opening 40 x 120 mm • Depth bath 150 mm • Pump 7 L/min • Excellent price value ratio Reliable Auxilary temperature control Small footprint Rapid cooling down Very quiet Precise control Cooling of other equipment like refractometers, thermostatic baths, viscometer baths, flashpoint, distillation, etc. 20
Aug. 2011 Tamson Low-temperature CirculatorTLC15-5, TLC30-5 • Stainless steel • -15..60°C, -30C..60°C • Optional -15..150°C • Stability ± 0.05°C • Bath drain • Level detection • RS232, free software • Can be used as small bath • Bath volume 5 L • Opening 85 x 150 mm • Depth bath 150 mm • Pump 7 L/min Reliable Auxilary temperature control Small footprint Rapid cooling down Very quiet Precise control Cooling of other equipment like refractometers, thermostatic baths, viscometer baths, flashpoint (Abel), etc. 21
Aug. 2011 Tamson Low-temperature CirculatorTLC40-14, TLC80-14, TLC90-14 • Stainless steel • -40°C, -80°C, -90°C .. Ambient. • Stability ± 0.05° • Bath drain • Level detection • Bath volume 14 L • Opening 240 x 160 mm • Depth bath 150 mm • Pump 7 L/min • RS232* • Suction / pressure pump* • Performance pump 16 L/min, max 1 bar* • Optional* Bath or circulation. Replace tap water. High C&P(D97) (TLC40) C&P(D97), CFPP (TLC80, TLC90) Flash point (Abel, IP170) TLC40. Connect multiple laboratory equipment. Distillation 22
Aug. 2011 Tamson Low-temperature CirculatorTLC80-14DP • Stainless steel • -80°C .. Ambient • Stability ± 0.05° • Bath drain • Level detection • Bath volume 14 L • Opening 240 x 160 mm • Depth bath 150 mm • Pump 10 L/min • Economical mode • RS232* • Suction / pressure pump* • Performance pump 16 L/min, max 1 bar* • Optional* • Heat removal 150W @ -80°C Bath or circulation. C&P(D97), CFPP Connect multiple laboratory equipment with only one cooler. Practical use -80 .. -40°C 23
Aug. 2011 Pump alternatives 24
Thermometer calibration Sensor calibration Aug. 2011 Visibility / Viscosity Baths ASTM D445 / IP 71A fewApplications Kinematic Viscosity • Other examples: • Chemical prosesses • Density (ASTM 1401) • Reaction rate 25
Aug. 2011 Tamson ViscosityTV2000 / new TV4000mkII / new TV7000mkII • Stainless steel • Ambient .. 230°C • 20, 40 or 70 L bath volume • Stability ± 0.01°C (display also 0.01°C) • RS232 + drain standard • Large (double) windows • Cooling coil + overflow outlet • Two holes for separate ASTM reference thermometer • Top lid for use with viscometer holders • Fine adjustable offset • Fully ASTM D445 • TV7000 fully ASTM D2162 • Backlight (optional) • Detachable window to clean inside window Designed for ultra precise measurement: Viscosity, calibration, crystal growing, density, reaction rate 26
Aug. 2011 Tamson ViscosityTV12 • Only 12 liter bath volume • Stability: ± 0.005°C • Small footprint: 32 x 34 cm • Span 15 .. 120°C (with external TLC10-3 through cooling coil) • Optional Span 15 .. 150°C • ASTM D 445 • Display readout: 0.01°C • Lid with 4 holes for viscometers • Built-in illumination (LED LIGHTS) • Detachable window to clean inside window • Stainless steel • Hole for separate ASTM reference thermometer Designed for ultra precise measurement: Viscosity, calibration, sensor calibration, density, reaction rate 27
1 2 3 4 4 5 6 7 Aug. 2011 Tamson ViscosityTV12 • RS232 • Motor Fuse • Fan • Built-in cooling coil (to work below ambient) • Overflow outlet • Mains Connector • Bath drain 28
Aug. 2011 Tamson ViscosityTV12 • Unique recovery time after temperature dip (caused by viscometers). • 3 times quicker than conventional bath. • This is strictly conform to ASTM D 445. 29
Aug. 2011 Tamson ViscositySemi - automated TV2000AKV • Stainless steel • Stability ± 0.01° • Ambient .. 120°C • 20 L bath volume • Measuring head Ubbelohde or Cannon Fenske • System can store 10 viscometers constants • Built-in timer • Infra red detection • Transparent / dark samples • Fully ASTM D445 Automated Kinematic Viscosity measurement 30
Aug. 2011 Tamson ViscosityTV2500 • Stainless steel • Stability ± 0.02° • Ambient .. 100°C • 4 positions for viscometer holder • Good visibility • 25 L bath volume • Cooling coil • RS232 • Can be used for ASTM D1298 with special cover and 500 mL cylinders Viscosity measurement Pulp, en polymer industry Sensor calibration Bitumen 31
Aug. 2011 Tamson Viscosity Low TemperatureTV4000LT / TV7000LT • 40 ltr or 70 ltr bath • Stability ± 0.02°C (0.01°C display) • RS232 • -40°C .. +100°C • Top lid for use with viscometer holders • Fine adjustable offset • Fully ASTM D445 • Excellent homogenety • Energy saving • Window heating • Can be used with Schott measuring head. • Standard drain Designed for ultra precise measurement at low temperature: Viscosity, calibration, density, reaction rate 32
Aug. 2011 Tamson Viscosity Low Temperature NEW TV12LT • Only 15 liter bath volume. • ASTM D445 • Display readout 0.01°C (0.001°C optional) • Lid with 4 holes for viscometers • Built-in illumination • Built-in cooling • Temperature range from -50 up to +80°C. • Detachable window to clean inside window • Window heating • Stainless steel • RS232 • Holes for separate ASTM reference thermometer • More than 50 units since production started in 2011 33
Aug. 2011 Tamson Viscosity Low TemperatureTLV25 • 25 ltrs bath • Stability ± 0.04°C • RS232 • Top lid for use with 3 viscometer holders • Complies to ASTM D445 • Window heating • Built-in illumination Designed for viscosity measurement at low temperature Operates down to -80°C Need an external cooler like the KV40 or KV80 34
Aug. 2011 Tamson Viscosity Low TemperatureCold probe cryostat • KV40 probe -40°C • KV80 probe -80°C • 2.5 mtr flexible hose • Compact probe 50 x 200mm • Easy operation The probe can be immersed directly in a fluid Applies heat removal on a spot Can be used together with the TLV25. 35
Aug. 2011 Accessories • Bath fluid • Viscosity accessories • 8-Channel Stopwatch • Backlight illumination • ASTM Thermometers • Digital Contact Thermometer • Reference Standards • Performance pump • Tubing • Manifold 36
Aug. 2011 Bath fluid • Mineral oil • (range 80 … 150°C) • Silicone oil transparent • (range 20 … 150°C) • (range 80 … 150°C) • (range 80 … 250°C) • Silicone oil opaque • Range 80 … 250°C • Important viscosity ≤10 cSt 37
Aug. 2011 Viscosity AccessoriesViscometer capillaries • Cannon Fenske Routine • Cannon Fenske Opaque • U-Tube (Ostwald) Routine • U-Tube (Ostwald) Opaque • Ubbelohde • Baume Vigneron • Houillon • S.I.L. • Zeitfuchs • Ubbelohde (TV2000-AKV) • Cannon Fenske (TV2000-AKV) • Other types on request Standard Calibration Certificate Optional UKAS certificate* 38
Aug. 2011 Viscosity AccessoriesViscometer holders • Cannon Fenske Opaque • Cannon Fenske Routine • Utube (Ostwald) Routine • Utube (Ostwald) Opaque • Ubbelohde • Pinkevitz Long • Pinkevitz Short • Insulated handle, easy tograb at high workingtemperatures • Stainless steel • Ring to hang out 39
Aug. 2011 Viscosity AccessoriesVisco hanger • Stainless steel • Leakage tray • Easy drainage • 7 viscometer tubes • 51 x 28 x 49 cm 40
Aug. 2011 8-Channel stopwatch • 8 channel • Easy to operate • Long battery life • Uses simple 9V block • Keeps value in memory after power off • 0.01 sec resolution • Saves bench space • Optional Calibration Certificate 41
Aug. 2011 Backlight Illumination • Z41 (TV2000, TV4000 TV4000LT, TV2500, TV2000-AKV) • Z71 (TV7000, TV7000LT) To be used when measurements have to be followed visually!! 42
Aug. 2011 ASTM Thermometers • These thermometers comply with the ASTM E1. • The glass thermometers are suitable for official calibration. • All thermometers have a sub division of 0.05C (0.1F) and are equipped with an ice-point scale. • To protect the thermometer for mechanical damage a stainless steel holders can be supplied 43
Aug. 2011 Tamson Thermometer 3 decimals TT-3 • Complies to IEC 751 • Accuracy of ± 0.01°C • Calibrated of 0.015°C • Resolution of ± 0.001°C. • Substitute for the commonly known mercury thermometer • Free Tamcom software • Range from -100 .. +250°C • Protective blue suitcase • Conforms to new requirements of ASTM D445 • Sensor element PT100 (Thermistor or PT100) • Display resolution 0.001°C (0.01°C) • Accuracy better than ±0.015°C (±0.015°C) • Linearity ±0.01°C (±0.01°C) • Fast responsetime 3sec (<6 sec) • Annual drift <± 0.001°C (<± 0.01°C) 44
Aug. 2011 Viscosity Calibration Standards To be used as a reference standard for viscosity measurements! • Primary Standard • Conforms to ASTM D2162 • ISO 17025 & ISO Guide 34 certified under UKAS • Values certified 20, 25, 40, 50 and 100°C • Up to 2 Years Shelf life • 0.5 liter bottles • Other ASTM references on request (e.g. TAN, TBN, Flashpoint, CRM.) See our extensive database at www.tamson.com 45
Aug. 2011 ASTM EquipmentA few products Kinematic Viscosity (ASTM D445/ASTM D446) LPG Sampling Copper Corrosion (ASTM D130) Density by hydrometer method (ASTM D1298, D287) 46
Aug. 2011 ASTM D130 & D4048Copper Corrosion • Range from +5°C..250°C • 6 positions • Holders for test cylinder • Holders for test tubes • Standard drain • All accessories are supplied by Tamson. • Can also be used as circulator 47
Aug. 2011 ASTM D1265, ISO EN 4057LPG Sampling • Comform EU 1999/36EC and ADR regulation (acc. ADR medium nr.1965). • Stainless steel 1.4541 • 600, 2300 and 3800 ml capacity • II and CE laser marking, sealable • Teflon coating is optional • Additional adapters available • Easy internal cleaning • Completely acetone resistant • We have certificates for whole product (not a part of it) allowing to use our tanks in all EU countries. • Strong base, impossible to knock over the container • Sampling pump optional 48
Aug. 2011 ASTM D1298, D287Density by hydrometer method • Solid/firm frame • Clear view on hydrometer • Easy cleaning & drainage • High quality glass • Leakage tray • Double wall cylinders • Cooling circulator • Range from +5°C .. +100°C 49
Aug. 2011 ASTM D1796 & ASTM D4007Waterbath to preheat the cones • Range from +5°C..250°C • 9 positions • Standard drain • With the levelling platform • you can immerse the • centrifuge cones in • the vertical position • to the 100-mL mark • Can also be used as • circulator 50