1 / 27

HYDRO CLICK SYSTEM

HYDRO CLICK SYSTEM. DEMANDS ON POTABLE WATER TANKS . Smooth surface Clean ability Resistance of lining against potable water (at chlorination up to 1 ppm) Absolute tightness No ground water infiltration through concrete wall (at buried tanks) . Potable Water Tanks – general

devin
Download Presentation

HYDRO CLICK SYSTEM

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HYDROCLICK SYSTEM

  2. DEMANDS ON POTABLE WATER TANKS • Smooth surface • Clean ability • Resistance of lining against potable water • (at chlorination up to 1 ppm) • Absolute tightness • No ground water infiltration through concrete wall (at buried tanks) • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals Currently used systems • Tiles • Coatings • Concrete without further treatment • Thermoplastic liners

  3. POTABLE WATER TANKS - GENERAL Problem:Coating of potable water tanks • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals Limited service life Contamination of potable water by detached particles

  4. POTABLE WATER TANKS - GENERAL • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals Problems caused by solvent water: Service life ? Maintenance ? Repair ?

  5. ADVANTAGES OF SYSTEM • Product approval acc. to KTW (for potable water) • Raw material approval DVGW-W270 (for pot. water) • No deposits on the tank wall • Easy to clean – high pressure resistance (130bar) • Good resistance against chlorination up to 3 ppm • (0,5 ppm free chlorine resp. 0,3 ppm ClO2) • Long service life (PE-pipes 50 years) • Fast installation / shorter construction times! • Ventilation gap avoids creation of aggressive condensates • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  6. 12-15mm 50mm ~ 2000mm HYDROCLICK SYSTEM • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals • extruded - calendared • max. width: 2000mm • thickness: 4mm • material: PE80 blue RAL 5012 HYDROCLICKprofile HYDROCLICKliner

  7. HYDROCLICK SYSTEM • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals HYDROCLICK profile coextruded with PEHD-el layer Distance studs (height ~ 9mm) Click stud (adjusted to the Click profile)

  8. HYDROCLICK SYSTEM Protective film • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals Perforation strip (on both sides 50mm)

  9. INSTALLATION Easy installation: • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals • No extensive preparation before installation • Tiles and coatings may be left in the tank if they are not loose • Second chamber can be operated without special efforts (no dust or odours)

  10. INSTALLATION Wall installation • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals Step 1: Sheet with click-studs is clicked into the profile which is mechanically fixed to the wall

  11. INSTALLATION Wall installation • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals Step 2: Second sheet is clicked into the profile Preparation of the welding area

  12. INSTALLATION Wall installation • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals Step 3: Extrusion welding DVS optimized

  13. INSTALLATION Ground-wall-transition • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  14. EPDM bar Stainless steel bar Sealing strip INSTALLATION Wall connection / Margin sections • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals Connection with PE sheet strip PE profile fixed

  15. INSTALLATION Wall-ground-transition with 45° chamfer • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals Drain section remains

  16. Thermoformed elements INSTALLATION Lining of columns • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  17. INSTALLATION Anchor element • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  18. REFERENCES / PROJECTS Project: Brig Switzerland • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  19. REFERENCES / PROJECTS Project: Vernate Switzerland • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  20. REFERENCES / PROJECTS Project: Leuggern Switzerland • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  21. REFERENCES / PROJECTS Project: Leuggern Switzerland • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  22. Project: Völkingen Germany REFERENCES / PROJECTS • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  23. Project: Oberschlierbach Austria REFERENCES / PROJECTS • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  24. REFERENCES / PROJECTS • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  25. LIMITATIONS System limitations of the HYDROCLICK system • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals • Applicable up to a max. temperature change of 10 °C • Max. application temperature: 30°C • Not recommended for back pressure build up • between concrete and liner • Not UV resistant

  26. APPROVALS • Potable Water Tanks – general • Hydroclick system • Installation • References • Limitations • Approvals

  27. THANK YOU

More Related