1 / 28

Seismic Design of Buried Structures

Seismic Design of Buried Structures. Doug Jenkins Interactive Design Services. Why Bother?.

dexter
Download Presentation

Seismic Design of Buried Structures

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Seismic Design of Buried Structures Doug JenkinsInteractive Design Services

  2. Why Bother? "Results show that the bending moments in the arch from horizontal earthquake loading can be significant in relation to the gravity load actions. These moments are also very sensitive to the backfill and surrounding soil stiffness properties and rather less sensitive to the foundation soils beneath the arch.” John Wood

  3. Collapse of buried structure in Japan Spec • Possible earthquake related failure south of Sydney • Consequences of failure

  4. Seismic design provisions in AS5100 • Specific rules are given for the categorisation of bridges. • A formula is given for the fundamental period of bridge structures (for use in category BEDC-1 designs only). • Specific structural response factors are given for bridges of different types. • Structural detailing requirements relevant to bridges are given.

  5. Problems with application to buried structures • The requirements for more detailed analysis methods are related to bridge span, and may not be relevant to buried structures. • Vertical earthquake effects may be important for buried structures, but only horizontal effects are required to be considered for almost all buried structures. • The formula for the fundamental period is not applicable to buried structures. • For static analysis the earthquake design force is not applicable to buried structures. • The appropriate response modification factor is not clear.

  6. Buried arch design study • Geraldton Southern Transport Corridor • 14.5 m span x8 m high • 3m and 15 m cover • Acceleration 0.10g • Site factor 1.5 • Bridge Type II

  7. Classification • Type III - Bridges and associated structures that are essential to post-earthquake recovery, as determined by the relevant authority. • Type II - Bridges that are designed to carry large volumes of traffic or bridges over other roadways, railways or buildings. • Type I - Bridges not of Type II or Type III.

  8. Classification

  9. Classification • BEDC-1 • < 20 m span, no earthquake analysis • > 20 m span, static analysis, horizontal forces • BEDC-2 • Static or dynamic analysis • > 35 m span, horizontal and vertical • BEDC-3 • Static analysis only if a single dominant mode • Consider horizontal and vertical loads • BEDC-4 • Dynamic analysis; horizontal and vertical

  10. Buried arch design study • For each fill height (3m and 15 m): • Natural frequency analysis • Deflection under unit horizontal acceleration • Pseudo-static analysis • Response Spectrum analysis • Push-over analysis

  11. Buried arch design study • For each of the analyses the following material stiffness properties were used: • Typical soil and uncracked concrete. • Soil stiffness reduced by half and uncracked concrete. • Soil stiffness reduced by half, and concrete moment-curvature relationship (static analyses), or cracked stiffness (response spectrum analyses) • A total of 26 separate analyses were carried out.

  12. Typical Finite Element Mesh

  13. Mesh Detail

  14. Fundamental period, Static Design Force Coefficient

  15. Static analysis, 3m Cover

  16. Dynamic Analysis, 3m Cover

  17. Maximum Moments, 3m Cover

  18. Static analysis, 15m Cover

  19. Dynamic Analysis, 15m Cover

  20. Maximum Moments, 15m Cover

  21. Axial Load - Seismic Increment or reduction, 15m Cover

  22. Animations • First mode shape - 3m and 15 m cover, horizontal and vertical • Arch + Fill • Fill only

  23. Moment-Curvature

  24. Push-over analysis, 15m Cover

  25. Animations • Push-over analysis • 15 m fill • 3 m fill

  26. Conclusions • Buried arch structures with low to moderate axial loads have a large reserve ductility. • Where the failure mode is concrete compression failure under moderate earthquake loading is a possibility. • Bending moments found in the dynamic analyses were up to 50% higher than the static analysis results.

  27. Recommendations • Structure classification be related to fill height, rather than span. • Response modification factor to be related to the capacity reduction factor. • BEDC-1 and BEDC-2: design for vertical and horizontal earthquake loads, using static or dynamic analysis. • BEDC-3 and BEDC-4: design for vertical and horizontal earthquake loads, using dynamic analysis. • Determine the fundamental period from computer analysis or formula for BEDC-1 and 2 structures. • T = 0.055 0.5 seconds •  = deflection in millimetres at ground surface above the arch under 1g horizontal load.

  28. Further Information • www.interactiveds.com.au

More Related