1 / 7

Trace metal distribution in the water column along 40°S

Trace metal distribution in the water column along 40°S. Christian Schlosser , Jessica Klar, Ebby Desai, and Eric Achterberg National Oceanography Centre Southampton. Cruise Track and Sampling Positions UK GEOTRACES 40°S. RRS James Cook JC068 (Dec. 2011 - Jan. 2012)

didina
Download Presentation

Trace metal distribution in the water column along 40°S

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Trace metal distribution in the water column along 40°S Christian Schlosser, Jessica Klar, Ebby Desai, and Eric Achterberg National Oceanography Centre Southampton

  2. Cruise Track and Sampling Positions UK GEOTRACES 40°S • RRS James Cook JC068 (Dec. 2011 - Jan. 2012) • 15 Ti casts (full depth) • 2 Ti cast (1000m) • ~150 surface sites • Trace Metal Sampling • Ti rosette frame with trace metal • cleanOTE bottles and self-triggering • bottle closure system • Fish • Analysis • Dissolved and total dissolvable Fe, Cd, • Pb, Cu, Ni, (Zn) by ID-ICP-MS • Dissolved and total dissolvable Ag, Mn • (Co) by standard addition ICP-MS • Dissolved and total dissolvable Al by • flow injection fluorescence (Brown and • Bruland, 2008)

  3. Preconcentration for Multi Element Analysis • 12 ml sample • Spiked with isotope mixture • Standard addition for mono-isotopic elements (Co, Mn) • UV digestion • Chelating resin WAKO • 1 ml elution with 1.5 M HNO3 • Measured on XR Element II HR ICPMS - 100 µl isotope mix - Standard addition Co/Mn - Buffer 1.5 M HNO3

  4. Preconcentration for Ag • 20 ml sample • Standard addition • 1 day equilibration • Dowex anion exchange resin • 2 ml elution with 1.5 M HNO3 • Measured on XSeries ICPMS - Standard addition Ag 1.5 M HNO3

  5. Preliminary Results Sta. 20 Sta. 13 Sta. 11

  6. Work in Progress • Multi trace element analysis of surface and subsurface samples from JC068 • and D357 by isotope dilution/standard Addition ICP-MS (end of October • this year) • Fe ligand analysis (beginning of next year) • Fluorescence dissolved organic matter (FDOM) (beginning of next year)

  7. Preconcentration • Chelating resin WAKO (similar to NOBIAS Chelate PA1) • methacrylate resin • carboxymethylated pentaethylenehexamine (CM-PEHA resin) • Excellent Mn measurements: stable Mn calibration slopes • Kagaya et al., Talanta 2009, 79: 146-152

More Related