1 / 8

STOPKIT Test - Ø 14” & Ø 6” Pipe Spools Set up

STOPKIT Test - Ø 14” & Ø 6” Pipe Spools Set up. Note:- Both pipe spools were Hydro tested at 120 BarG prior to drill to perform the STOPKIT TEST. 14”Ø Pipe 6mm Hole at Plain Pipe. 6”Ø Elbow 4mm Hole at Weld Heat Affected Zone. STOPKIT Test by PLS and Gasco attendees from HQ & Sites.

dillon
Download Presentation

STOPKIT Test - Ø 14” & Ø 6” Pipe Spools Set up

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. STOPKIT Test - Ø14” & Ø6” Pipe Spools Set up Note:- Both pipe spools were Hydro tested at 120 BarG prior to drill to perform the STOPKIT TEST 14”Ø Pipe 6mm Hole at Plain Pipe 6”Ø Elbow 4mm Hole at Weld Heat Affected Zone

  2. STOPKIT Test by PLS and Gasco attendees from HQ & Sites

  3. STOPKIT Test at 14ӯ Plain Pipe with a 6mm Hole Arresting an air Leak Under 7.0 BarG Pressure. Ear protection required due to high noise level. Leak Arrested at 10 N.m Torque. Note:- After air test the spool was filled with water and successfully tested at 80 BarG - 20 N.m Torque

  4. STOPKIT Test 6” Elbow with a 4mm Hole at Weld HAZ Water Leak with Initial Pressure kept at 2.5 BarG. As the leak rate started to be reduced the pressure was gradually increased to 80.0 BarG to assess the STOPKIT performance.

  5. STOPKIT Test 6” Elbow with a 4mm Hole at Weld HAZ 40 N.m Torque Applied Pressure 80.0n BarG Minor Leak - Tear 44 N.m Final Torque Leak Permanently Arrested

  6. STOPKIT Final Test at 80.0 BarG - Ø6”Elbow & Ø14” Pipe 6” Elbow 80.0 BarG 14”Ø Pipe

  7. STOPKIT 100 – Large Pad for Major Leaks STOPKIT 100 25mm Hole on Plain Pipe Pressurized up to 36.0 BarG. Evidence of Leak at around 30.0 BarG. Pressure Stabilized at 25.0 BarG – Leak Stopped

  8. STOPKIT 50 – Smaller Pad for pinholes STOPKIT 50 4mm Hole on Top of the Weld - Tested up to 36.0 BarG. No Evidence of Leaks

More Related