1 / 5

EMU DAQ Network Sketch

Crate-Power Control PC. CANbus control/monitoring. ~50 Peripheral Crates (~50 10-base FL Dynatem). EMU DAQ Network Sketch. Central DAQ. PC Controller for EMU-DAQ Counting House? FED Crate Control? Linux!. CMS TCS. EMU DCS. CSC HV. FM/TTS. EMU DAQ. Soft-wire Fast Monitoring line.

doli
Download Presentation

EMU DAQ Network Sketch

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Crate-Power Control PC CANbus control/monitoring ~50 Peripheral Crates (~50 10-base FL Dynatem) EMU DAQ Network Sketch Central DAQ PC Controller for EMU-DAQ Counting House? FED Crate Control? Linux! CMS TCS EMU DCS CSC HV FM/TTS EMU DAQ Soft-wire Fast Monitoring line Few gigabit lines in, ~20 100-base T out Ethernet hub or switch 10-base T fan-out hub or switch 100-base T ~20 lines, 1 per PC 10-base T 10-base T 10-base T -to- 10-base FL Converter ~50 converters needed, with 16 per 2U module Local Net Gigabit Fiber CAN bus Key: Fiber optic line ~50 fibers (10-base FL) to peripheral crate Dynatems Other Ethernet 18 Rack PCs + 3 DDU Crates (18 100-base T) (3 10-base T Dynatem) CAN bus Unspecified

  2. EMU Electronics DCS Tasks • Peripheral Crate Slow Control • via Dynatem crate controller with 10-base FL Ethernet • FPGA/PROM reconfiguration • Calibration setup and offline reset/reprogram control • DAC output level readout • Temperature readout (CFEB, DMB, …) • Test/Debug mode controls • LVMB readout • DDU Crate Slow Control • via Dynatem or PCI-VME (requires a server PC) crate controller • FPGA/PROM reconfiguration • Calibration setup and offline reset/reprogram control • Test/Debug mode controls • Soft-wire fast monitoring readout to FM system • Warning/Error status register (VME) from DDU

  3. Other EMU DCS Tasks • Rack PC Slow Control (via external gigabit line) • Readout of SPY data, stand-alone DAQ data (calibration) • Readout events/histograms and processed calibration tables • Each rack PC reads out ~2 DDUs via local (private) gigabit lines • Crate Power Control/Monitoring (CAN bus?) • On/off crate power control (peripheral and counting house) • Current/voltage/temperature monitoring • Fan activity & humidity monitoring? • CSC High-Voltage Control/Monitoring (Ethernet?) • On/off module (and crate) power control • Current/voltage/temperature monitoring • Fan activity & humidity monitoring? • Ethernet? Fiber-optic or copper?

  4. CERN/CMS/EMU DCS Tasks • Gas Flow/Mix/Pressure Monitoring • Service for CSCs provided by CERN? • Required in DAQ readout for track reconstruction? • Interruption of flow should shut down CSC HV? • Radiation Monitoring • Alarm for high-rate conditions • Causes power-off or beam dump? • Database of TID for electronic systems • Localized monitoring? What do we need? • Alignment • Monitored by CMS DAQ? • LVAC (400 Hz), LVDC and converters • Service provided by CMS? • Current/voltage/temperature monitoring? • Fan activity & humidity monitoring?

  5. Future EMU DCS Options • 18 Rack PCs may share functions • Distributed peripheral crate Dynatem Slow Control • Each rack PC controls a specific section of the detector • Possible complications for calibration control in TTC system • Many possible network configurations… • Multiple functions may be grouped into one PC • So-called “19th” PC • Could simplify calibration control, but may be difficult to implement… • Surface or counting house? Desktop, rack mount or on top of rack? • Central server/hub for rack PCs • Link to EMU TTC partition control and Main Run Control • Server/hub for peripheral crate Dynatem Slow Control • PCI-VME server functions for DDU crate control • Requires location in counting house near DDU rack • DDU crate 10—base T lines replaced by PCI bus • Crate-Power control/monitoring • CAN bus to PCI conversion • Centralized location for soft-wire link to Fast Monitoring system • Use as primary EMU DCS server? • Requires links to CSC-HV and Central DCS