1 / 10

Thermal Protection System Testing in High Enthalpy Facility

Team HEaTT. Thermal Protection System Testing in High Enthalpy Facility. Progress Report #4. Richard French Vitaliy Grigoryev November 17, 2005. Summary. Schedule Update Testing Update Improvements Preliminary Lessons Learned Immediate Needs. Schedule.

doyle
Download Presentation

Thermal Protection System Testing in High Enthalpy Facility

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Team HEaTT Thermal Protection System Testing in High Enthalpy Facility Progress Report #4 Richard French Vitaliy Grigoryev November 17, 2005

  2. Summary • Schedule Update • Testing Update • Improvements • Preliminary Lessons Learned • Immediate Needs

  3. Schedule

  4. Testing Overview - Ongoing • Fully Characterize HETF - Test Section Temperature Profile - Mounting Stand Conduction - Wall Temperature • Axial Temperature Probe

  5. Axial Temperature Probe • 1 meter Uni-strut • 7 J-type thermocouples • Variable Test-to-Test Flame Temperature - Raise and lower on pulley system

  6. Testing Overview - Planned • Establish Effective Operating Procedures - Wire Harness Protection - Measurement Confidence - Test Duration Limits • Shuttle Tile Sample Test

  7. Improvements • High temperature thermal cement for thermocouple interface • Better wire harness shielding • Pitot Probe re-positioned to rear, with thermocouple installed

  8. Preliminary Lessons • Steady state measurements difficult to obtain - Temperature fluctuations due to non- uniform flow • Thermal inertia of Test Stand, Axial Probe may affect measurements

  9. Immediate Needs • High temp thermocouple for measuring flame temp • Verify thermocouple calibration • Digital Data Acquisition System • K-thermocouple wire to make better use of analog equipment • Space Shuttle Tile!!!

  10. Thanks QUESTIONS?

More Related