1 / 17

Benziger Group

Benziger Group. Electro-osmotic Drag Observations and Results Monday, July 7 2008. Princeton University. 06/27/08 – IV Sweep # 1 – T (FC) = 50°C. First ARBIN test with H2 Current ramp (CR) to 1.8A, followed by current hold (CH):.

drea
Download Presentation

Benziger Group

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Benziger Group Electro-osmotic Drag Observations and Results Monday, July 7 2008 PrincetonUniversity

  2. 06/27/08 – IV Sweep # 1 – T(FC) = 50°C • First ARBIN test with H2 • Current ramp (CR) to 1.8A, followed by current hold (CH): Rint (before CR) = 0.390 Ω :: Rint (after CH) = 0.256 Ω H2 = 410 mL/min :: N2 = 200 mL/min PrincetonUniversity

  3. 06/30/08 – IV Sweep # 1 – T(FC) = 50.8°C • Current ramp to 1.8A, followed by current hold: Rint (before CR) = 0.608 Ω :: Rint (after CH) = 0.359 Ω H2 = 410 mL/min :: N2 = 200 mL/min Mass Transfer Limitation Region: Where is it?? PrincetonUniversity

  4. 06/30/08 – IV Sweep # 1 – T(FC) = 50.8°C Rint (before CR) = 0.608 Ω :: Rint (after CH) = 0.359 Ω H2 = 410 mL/min :: N2 = 200 mL/min Voltage vs. Time during 1.8 A Current Hold step PrincetonUniversity

  5. 06/30/08 – IV Sweep #2 – T(FC) = 52.1°C • Current ramp to 1.9A, followed by current hold: Rint (before CR) = 0.807 Ω :: Rint (after CH) = 0.367 Ω H2 = 410 mL/min :: N2 = 200 mL/min Mass Transfer Limitation Region: Where is it?? PrincetonUniversity

  6. 06/30/08 – IV Sweep #2 – T(FC) = 52.1°C Rint (before CR) = 0.807 Ω :: Rint (after CH) = 0.367 Ω H2 = 410 mL/min :: N2 = 200 mL/min Voltage vs. Time during 1.9 A Current Hold step PrincetonUniversity

  7. 06/30/08 – IV Sweep #3 – T(FC) = 51.2°C • Current ramp to 1.9A, followed by current hold: Rint (before CR) = 0.463 Ω :: Rint (after CH) = 1.82 Ω H2 = 410 mL/min :: N2 = 100 mL/min Mass Transfer Limitation Region: Where is it?? PrincetonUniversity

  8. 06/30/08 – IV Sweep #3 – T(FC) = 51.2°C Rint (before CR) = 0.463 Ω :: Rint (after CH) = 1.82 Ω H2 = 410 mL/min :: N2 = 100 mL/min Voltage vs. Time during Current Hold step PrincetonUniversity

  9. 06/30/08 – IV Sweep #4 – T(FC) = 80°C • Current ramp to 1.2A, followed by current hold: Rint (before CR) = 0.455 Ω :: Rint (after CH) = 0.750 Ω H2 = 410 mL/min :: N2 = 100 mL/min Mass Transfer Limitation Region: Where is it?? PrincetonUniversity

  10. 06/30/08 – IV Sweep #4 – T(FC) = 80°C Rint (before CR) = 0.455 Ω :: Rint (after CH) = 0.750 Ω H2 = 410 mL/min :: N2 = 100 mL/min Voltage vs. Time during 1.2A Current Hold step PrincetonUniversity

  11. 06/30/08 – IV Sweep #5 – T(FC) = 80°C • Current ramp to 1.9A, followed by current hold: Rint (before CR) = 0.715 Ω :: Rint (after CH) = 1.32 Ω H2 = 410 mL/min :: N2 = 100 mL/min Mass Transfer Limitation Region: Where is it?? PrincetonUniversity

  12. 06/30/08 – IV Sweep #5 – T(FC) = 80°C Rint (before CR) = 0.715 Ω :: Rint (after CH) = 1.32 Ω H2 = 410 mL/min :: N2 = 100 mL/min Voltage vs. Time during 1.9A short Current Hold step PrincetonUniversity

  13. 07/01/08 – IV Sweep #1 – T(FC) = 78.6°C • Current ramp to 0.6A, followed by current hold: Rint (before CR) = 3.67 Ω :: Rint (after CH) = 0.858 Ω H2 = 410 mL/min :: N2 = 100 mL/min PrincetonUniversity

  14. 07/01/08 – IV Sweep #5 – T(FC) = 78.6°C Rint (before CR) = 3.67 Ω :: Rint (after CH) = 0.858 Ω H2 = 410 mL/min :: N2 = 100 mL/min Voltage vs. Time during Current Hold step PrincetonUniversity

  15. 07/01/08 – RH[C] Temp vs. Time – T(FC) = 78.6°C PrincetonUniversity

  16. 07/01/08 – %RH[C] vs. Time – T(FC) = 78.6°C PrincetonUniversity

  17. 07/01/08 – %RH[C] vs. Time – T(FC) = 78.6°C PrincetonUniversity