40 likes | 162 Views
SEM403 Study of Orbit Separation. Last study of this sort was performed May 2001 Two weeks ago comment was made that separation of injection orbit from closed orbit was 30mm at SEM403 and ISEP. Look at models, do the experiment and look at modified Debuncher Injection Septum. Closed Orbit.
E N D
SEM403 Study of Orbit Separation • Last study of this sort was performed May 2001 • Two weeks ago comment was made that separation of injection orbit from closed orbit was 30mm at SEM403 and ISEP. • Look at models, do the experiment and look at modified Debuncher Injection Septum
Closed Orbit Injection Orbit A few mysteries: -Missing wire data in Hor. -Beam emittance much smaller than admittance Debuncher scraper IN No circulating beam
Many Numbers Frank Bieniosek pbar note #595 Jun 1998 (includes max 6.81rad @ 64.5kV) OptiM beamline model Nov 2004 IKIK to ISEP
What Separation is Needed at the Downstream End of the Injection Septum? • y =9.95m • 40(35) mm-mrad beam • Beam half width is 19.95(18.66)mm • Material between injection channel of ISEP and closed orbit chamber: • “Was” {separate vacuum} 12.27mm • “Modified” {common vacuum} 5.72mm • Separation Needed • “Was” 52.2(49.6)mm • “Modified” 45.6(43.0)mm