An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Ay 191 Experiment • Development of Hard X-ray Imaging Detectors • J. Hong and J. Grindlay • Hard X-rays (~10-600 keV) are direct probes of black holes: GRBs, AGNs, Stellar BHs, etc. • Direct imaging possible only for narrow FoV (<~0.1º) and only for low energies (<~100 keV) => coded-aperture telescope • Harvard balloon-borne telescope (ProtoEXIST) is a coded-aperture telescope for wide-field (~20ºx20º) hard X-ray imaging and is a prototype platform for development of the • scanning telescope needed for a major NASA mission, • EXIST, to conduct a very sensitive all-sky survey for BHs

  2. Coded-Aperture Hard X-ray Imaging Telescope Decoding Shadowgram allows wide-field imaging. Position-sensitive hard X-ray detectors needed: Use Cd-Zn-Te (CZT) arrays.

  3. Cd-Zn-Te (CZT) Hard X-ray imaging detector CZT Detectors 8 x 8 pixels on each 20 x 20mm CZT crystal (pixels on bottom) Schematic CZT detector: Electrons drift to anode Under ~700V bias

  4. CZT detectors: prototype lab array

  5. ProtoEXIST detector array 4cm x 8cm Detector Crystal Array (DCA)

  6. Balloon-borne ProtoEXIST Telescope Energetic X-ray Imaging Telescope Experiment (ProtoEXIST) with 1000 cm2 CZT detectors

  7. Ay191 experiments • Learn about • -Hard X-ray sources in the sky: Black holes … • -Hard X-ray Imaging: Coded-aperture telescopes • -Hard X-ray Detectors: CdZnTe detector • Experiments to be conducted (at CfA ProtoEXIST lab, B-105): • -Calibrating new CZT imager with 60, 122, 356 keV sources • -Measuring spatial and spectral resolution over detector • -Sensitivity to multi-pixel (split) events • -Cooling test (to -10°C) with CZT modules • -Design considerations for ProtoEXIST balloon-telescope